For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.25.060 — Fans

Municipal Code of the City of Evansville, Indiana (legislation through 06-22-2026) · Evansville Municipal Code § 15.25.060

Corpus is an independent public-information project, not the official City of Evansville website. Stable reference: corpuslaw.us/code/d90e6d22-f299-45e5-8cf2-1e75a418013b

§ 15.25.060: Fans.

In wrecking or extensively remodeling buildings over 40 feet high, fans shall be provided at each alternate story level in addition to fences and bridges required by EMC §§ 15.25.040 and 15.25.050. The fans shall project from the side of the building not less than six feet, and shall be designed for a live load of 100 pounds per square foot for a distance of five feet out from the wall line. The lookouts or supports shall be not less than two-inch by 12-inch joists spiked together and spaced not over eight feet on center, cantilevered on the wall, and adequately anchored to beams, girders, or joists of the building with steel cables or bolts of sufficient strength to withstand the maximum load which can be applied to the fan outside of the building. The entire area of the fan shall be floored with two-inch plank laid tight and solid plank guard rails three feet in height shall be provided on the outer edge and the ends of the fan rigidly braced and secured to lookouts.

( 1962 Code § 1341.12 ; 1982 Code § 150.105 ; 1983 Code § 15.150.105 )