For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 744-201 — General dimensional standards

Revised Code of the Consolidated City and County of Indianapolis-Marion County (Supp. No. 47, Update 2: codified through Ordinance No. 42, 2026, passed June 1, 2026) · Indianapolis-Marion County Revised Code § 744-201

Corpus is an independent public-information project, not the official City of Indianapolis website. Stable reference: corpuslaw.us/code/d0260102-0b2d-4d82-be97-4bfc19b62cd3

Sec. 744-201. - General dimensional standards.

A. Primary dimensional standards. All development in all Zoning Districts shall comply with the primary dimensional standards in this Section 744-201; and shall also comply with standards in Section 744-202 (New Construction for Nonconformities), Section 744-203 (Special Dimensional Standards), Section 744-204 (Height Exceptions and Yard Encroachments) and Section 744-205 (Stream Protection Corridors) as applicable to the development; and any dimensional requirements in Chapter 743, Article III (Use-Specific Standards), as applicable to the uses included in the development; and any dimensional requirements in Chapter 742, Article II (Secondary Districts) as applicable to the property. In case of any conflict between the dimensional standards in any of the referenced sections, the strictest provision shall apply. B. Dwelling Districts. Dimensional standards for Dwelling Districts are shown in Table 744-201-2. Units are in feet unless indicated otherwise. Table 744-201-1: Dimensional Standards for Districts D-A through D-5II Standards apply to Metro and Compact Context Areas unless indicated otherwise. Units are in feet unless indicated otherwise. District Standard | D-A | D-S | D-1 | D-2 | D-3 | D-4 | D-5 [6][7] | D-5II [6][7] | D-8 [3][6][7] Lot [1] Minimum Lot Area Single-family Detached | 3 acres | 1 acre | 24,000 sf | 15,000 sf | 10,000 sf | 7,200 sf Two-family Dwelling | N/A | N/A | N/A | 20,000 sf | 15,000 sf | 10,000 sf Single-family Attached | N/A | N/A | N/A | N/A | N/A | N/A | N/A Minimum Lot Width Single-family Detached | 250 | 150 | 90 | 80 | 70 | 60 Two-family Dwelling | N/A | N/A | N/A | 120 | 105 | 90 Single-family Attached | N/A | N/A | N/A | N/A | N/A | N/A | N/A Minimum Street Frontage Single-family Detached | 125 | 75 | 45 | 40 | 35 | 30 | 25 | 25 | 30 Two-family Dwelling | N/A | N/A | N/A | 40 | 35 | 30 | 25 | 25 | 30 Single-family Attached | N/A | N/A | N/A | N/A | N/A | N/A | N/A | 20 | 20 Minimum Total Open Space | 85%/50% [2] | 85% | 80% | 75% | 70% | 65% Maximum Height Primary Building Height | 35 | 35 | 35 | 35 | 35 | 35 Primary Building Height may increase 1 ft. per 1 ft. of additional side setback up to: | 45 | 45 | 45 | N/A | N/A | N/A | N/A | N/A | N/A Maximum Accessory Building Height [5] | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 Accessory Building Height may increase 1 ft. per 1 ft. of additional side setback up to: [5] | 45 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A Minimum Floor Area for Primary Dwelling Unit Main Floor of a 1-story dwelling | 1200 sf | 1200 sf | 1200 sf | 1200 sf | 1200 sf | 900 sf | 900 sf | 800 sf | 800 sf Main Floor of a dwelling over 1 story | 800 sf | 800 sf | 800 sf | 800 sf | 660 sf | 660 sf | 660 sf | 660 sf | 660 sf Total Floor Area for primary dwelling units | 1200 sf | 1200 sf | 1200 sf | 1200 sf | 1200 sf | 900 sf | 900 sf | 800 sf | 800 sf Minimum Setbacks in Metro Context Area [1] [4] Fronts Along Expressways and Freeways | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 Fronts Along Primary and Secondary Thoroughfares | 40 from proposed ROW | Greater of 60 from proposed ROW or average setback | Greater of 50 from proposed ROW or average setback | 40 from proposed ROW | 35 from proposed ROW | 35 from proposed ROW Fronts Along Collector Streets | 35 | Greater of 40 from proposed ROW or average setback | Greater of 30 from proposed ROW or average setback | 30 | 30 | 30 Fronts Along Local Streets | 35 | Greater of 40 from proposed ROW or average setback | Greater of 30 from proposed ROW or average setback | 25 | 25 | 25 Fronts Along Cul-de-sacs | 30 | 30 | 25 | 25 | 20 | 20 Side Yard Each/Combined | 30/75 | 15/35 | 8/22 | 7/19 | 6/16 | 5/13 Rear Yard General/Along Rail Track | 75/50 | 25/50 | 25/50 | 25/50 | 20/50 | 20/50 | [6]/50 | [6]/50 | [6]/50 Minimum Setbacks in Compact Context Area [1][4] Fronts Along Expressways and Freeways | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 Fronts Along Primary and Secondary Thoroughfares | 40 | Greater of 60 or average setback | Greater of 50 or average setback | 40 | 30 | 30 Fronts Along Collector and Local Streets and Cul-de-sacs | 35 | Greater of 40 or average setback | Greater of 30 or average setback | 25 | 20 | 20 Each Side Yard | 30 | 15 | 8 | 7 | 4 | 4 Table 744-201-1: Dimensional Standards for Districts D-A through D-5II Standards apply to Metro and Compact Context Areas unless indicated otherwise. Units are in feet unless indicated otherwise. District Standard | D-A | D-S | D-1 | D-2 | D-3 | D-4 | D-5 [6] [7] | D-5II [6] [7] | D-8 [3] [6] [7] Rear Yard General/Along Rail Track | 75/50 | 25/50 | 25/50 | 25/50 | 20/50 | 20/50 | [6]/50 | [6]/50 | [6]/50 Notes: [1] See also Section 744-202 - New Construction for Nonconformities. [2] On lots 3 acres or less, the minimum open space requirement shall be 85%. For lots over 3 acres, the minimum open space requirement shall be 50%. [3] Standards apply to lots for Single-family detached dwellings, Single-family attached dwellings, or Two-family dwellings. [4] Front setbacks are always measured from an existing right-of-way line unless otherwise indicated. See also Sections 744-202 through 744-204; in particular note Section 744-202.D - Front Setback Exceptions - Section 744-203.A - Land Within the Town of Meridian Hills - and Section 744-203.C - Side Yard Setback Exception for Zero-Lot Line Option. [5] However, the height of an accessory building may not exceed the height of the primary building unless excepted in Section 744-204. [6] See also Table 742.103.03 - Residential Building Type Standards, for Walkable Neighborhood Dwelling District dimensional standards not found in this table. [7] See also Table 744-701-2: Private Frontage Design Standards for frontage standards not found in this table. [8] Minor residential structures shall not be located closer to any rear lot line than 5 feet, see also Section 743-306. Table 744-201-2: Dimensional Standards for Districts D-6 through D-11 All standards apply to both Metro and Compact Context Areas. Units are in feet unless indicated otherwise. District Standard | D-6 | D-6II | D-7 | D-8 [3][6][7] | D-9[6][7] | D-10[6][7] | D-11 Lot Minimum Project Area | [1] | [1] | N/A | N/A | N/A | N/A | 15 acres Minimum Lot Area for a lot with a: Single-family Attached Dwelling | 2,400 | 2,400 | 2,000 | N/A | N/A | N/A Two-family Dwelling | 4,000 | 4,000 | 3,000 | N/A | N/A | N/A Triplex | N/A | N/A | N/A | N/A Fourplex | N/A | N/A | N/A | N/A Minimum Street Frontage for a Project | 150 | 150 | 100 | 50 | 150 | 100 | 150 Minimum Street Frontage for a lot with a: Single-family Attached Dwelling | 20 | 20 | 18 | See Table 744-201-1 | N/A Two-family Dwelling | 35 | 35 | 30 | See Table 744-201-1 | N/A | N/A | N/A Triplex | 50 | 50 | 35 | 30 | N/A Fourplex | 50 | 50 | 40 | 40 | N/A | N/A | N/A Minimum Setbacks and Yards [2] Front Setback: Fronts Along Expressways and Freeways | 30 | 30 | 30 | 30 | 30 | 30 | 30 Fronts Along Primary and Secondary Thoroughfares | 30 from proposed ROW | 30 from proposed ROW | 25 from proposed ROW | 30 from proposed ROW | 30 from proposed ROW | 25 from proposed ROW | 60 from proposed ROW Fronts Along Collector Streets | 30 | 25 | 25 | 25 | 25 | 25 | 60 Fronts Along Local Streets | 30 | 25 | 20 | 20 | 25 | 25 | 60 Perimeter Yard for a Project | 30 | 25 | 20 | N/A | 20 | 20 | 50 Distance Between Primary Buildings in a Project | 25 | 25 | 20 | 20 | 20 | 20 | 25 Side Yard on a lot with a: [4] Single-family Attached Dwelling | 15 | 15 | 10 | N/A Two-family Dwelling | 15 | 15 | 10 | N/A | N/A | N/A Triplex | 15 | 15 | 10 | N/A Fourplex | 15 | 15 | 10 | N/A Rear Yard on a lot with a: [4] Single-family Attached Dwelling | 15 | 15 | 10 | N/A Two-family Dwelling | 15 | 15 | 10 | N/A | N/A | N/A Triplex | 15 | 15 | 10 | N/A Fourplex | 15 | 15 | 10 | 15 | N/A | N/A | N/A Setback from a Railroad Track ROW | 50 | 50 | 50 | 50 | 50 | 50 | 50 Maximum Height Primary Building Height Maximum Height | 45 | 45 | 56 | N/A If abutting a lot or adjacent to a lot separated by a right-of-way less than 30' that is improved with a single-family detached dwelling, maximum height | 35 | 35 | 40 Maximum Accessory Building Height [5] | 25 | 25 | 25 | 25 | 25 | 25 | 20 Maximum Floor Area Ratio (FAR) for sites with buildings: 1 to 3 floors | 0.40 | 0.55 | 0.70 | 0.60 | 0.50 | 0.60 | N/A 4 to 5 floors | N/A | N/A | 0.70 | 0.80 | 0.80 | 0.80 | N/A 6 to 11 floors | N/A | N/A | N/A | N/A | 1.50 | 1.50 | N/A 12 to 23 floors | N/A | N/A | N/A | N/A | 2.20 | 3.00 | N/A 24 floors or more | N/A | N/A | N/A | N/A | 2.20 | 3.20 | N/A Minimum Livability Space Ratio (LSR) | 1.80 | 1.30 | 0.95 | 0.66 | 0.75 | 0.66 | N/A Notes: [1] See also Section 744-202.C.2. - Lot Area and Width Exceptions for D-6 and D-6II districts. These exceptions apply to the setbacks as platted. [2] Front setbacks are always measured from an existing right-of-way line unless otherwise indicated. [3] These standards apply to D-8 sites not used for Single-family detached dwelling, Single-family attached dwelling, or Two-family dwelling. [4] Common, unpierced walls that separate two dwellings are not required to meet side or rear yard setbacks. [5] However, the height of an accessory building may not exceed the height of any primary building. [6] See also: Table 742.103.03 - Residential Building Type Standards, for Walkable Neighborhood Dwelling District dimensional standards not found in this table. [7] See also Section 744.701.C - Private Frontage Types, for Private Frontage Standards not found in this table. [8] Minor residential structures shall not be located closer to any rear lot line than 5 feet, see also Section 743-306. C. Commercial Districts. Dimensional standards for Commercial Districts are shown in Table 744-201-3. Table 744-201-3: Dimensional Standards for Districts C-1, C-3, C-4, C-5, C-7 and C-S Dimensions apply to both Metro and Compact context areas unless indicated otherwise. Units are in feet unless indicated otherwise. District Standard | C-1 | C-3 | C-4 | C-5 | C-7 | C-S Lot Minimum Street Frontage | 50 | 50 | 50 | 50 | 50 | 50 Minimum Setbacks in Metro Context Area [1] Fronts Along Expressways and Freeways Minimum | 10 from proposed ROW or existing ROW, whichever is greater Maximum | N/A | N/A | N/A | N/A | N/A | N/A Fronts Along Primary and Secondary Thoroughfares, Collector or Local Streets Minimum | 10 from proposed ROW or existing ROW, whichever is greater Maximum | 85 from proposed ROW | 85 from proposed ROW | N/A | N/A | N/A | 85 from proposed ROW Front Transitional Yard | 20 | 20 | 20 | 20 | 20 | 20 Side and Rear Yard [2] | 10 | N/A | N/A | 10 | 10 | 10 Side and Rear Transitional Yard | 15 | 20 | 20 | 20 | 40 | 15 Transitional Yard Abuts an Alley | 10 | 10 | 10 | 10 | 20 | 10 Minimum Setbacks in Compact Context Area [1] Front Yard Minimum | 10 | 10 | 10 | 10 | 10 | 10 Front Yard Maximum | 65 | 65 | 65 | N/A | N/A | 65 Front Transitional Yard | 10 | 10 | 10 | 10 | 10 | 10 Side and Rear Yard | N/A | N/A | N/A | 10 | 10 | 10 Side and Rear Transitional Yard | 10 | 10 | 10 | 15 | 20 | 10 Transitional Yard Abuts an Alley | 8 | 8 | 8 | 10 | 10 | 8 Maximum Height in Metro Context Areas Buildings and Structures Height | 50 | 35 | 65 | 65 | 35 | 45 Buildings and Structures Height Along a Transitional Yard | 35 | 18 | 18 | 18 | 18 | 35 Buildings and Structures Height Along a Transitional Yard may increase 1 ft. per 1 ft. of additional side setback up to: | 50 | 35 | 65 | 65 | 35 | 45 Maximum Height in Compact Context Areas Buildings and Structures Height | 38 | 38 | 65 | 65 | 38 | 38 Buildings and Structures Height Along a Transitional Yard | 25 | 25 | 25 | 25 | 25 | 25 Buildings and Structures Height Along a Transitional Yard may increase 1 ft. per 1 ft. of additional side setback up to: | 38 | 38 | 65 | 65 | 38 | 38 Notes: [1] Front setbacks are always measured from an existing right-of-way line unless otherwise indicated. [2] See also Section 744-202.E.2. Side and Rear Yard Setback Exceptions. D. Mixed-Use Districts. Dimensional Standards for Mixed-Use Districts are shown in Table 744-201-4. Table 744-201-4: Dimensional Standards for Mixed-Use Districts MU-1 through MU-4 All standards apply to both Metro and Compact Context Areas unless indicated otherwise. Units are in feet unless indicated otherwise. District Standard | MU-1 | MU-2 | MU-3 | MU-4 Lot Street Frontage Minimum | 50 | 50 | N/A | N/A Maximum [1] | (block length) | (block length) | (block length) | (block length) Open Space (%) Minimum | N/A | N/A | 20% | 10% Maximum | N/A | N/A | 50% | 40% Setbacks [2] Front Yard Minimum | 12 | 5 | N/A | N/A Maximum | 40 | 20 | 12 | 12 Front Transitional Yard | 20 | 12 | 12 | 12 Side Yard | 10 | N/A | N/A | N/A Side Transitional Yard/ Abutting alley | 15 | 15/10 | 10/10 | 10/10 Rear Yard | 10 | N/A | N/A | N/A Rear Transitional Yard/ Abutting alley | 15 | 15/10 | 10/10 | 10/10 Height [3] Primary Building Height Minimum | 25 | 18 | 18 | 35 Maximum | N/A | 35 | 50; 75 with bonuses | 50; 90 with bonuses Transitional Building Height Minimum | 25 | 18 | 18 | 25 Maximum | 45 | 35 | 35 | 50 Accessory Building Height Maximum | 25 | 25 | 25 | 25 Notes: [1] Maximum lot width is the block width maximum indicated in the District or as platted whichever is the lesser. [2] Front setbacks are always measured from an existing right-of-way line unless otherwise indicated. [3] Height bonuses are in the individual MU Districts: 742-105. E. Central Business Districts. Dimensional Standards for Central Business Districts are shown in Table 744-201-5. Table 744-201-5: Dimensional Standards for Central Business Districts CBD-1, CBD-2, CBD-3 Units are in feet unless indicated otherwise. District Standard | CBD-1 | CBD-2 | CBD-3 Lot Maximum Coverage | 100% | 100% | 100% Minimum Setbacks [1] Front Yard | N/A | N/A | N/A Side and Rear Yard | N/A | N/A | N/A Side or Rear Yard Not Abutting an Alley [2] | 0 or 10 | 0 or 10 | 0 or 10 Maximum Height Sky Exposure Planes (see diagrams with definitions) | Planes 1 and 3 | Plane 2 | N/A Notes: [1] Front setbacks in CBD Districts are always measured from an existing right-of-way line unless otherwise indicated. [2] No setback is required; however if one is provided, it must be at least 10 feet. F. Industrial Districts. Dimensional Standards for Industrial Districts are shown in Table 744-201-6. Table 744-201-6: Dimensional Standards for Districts I-1 through I-4 All standards apply to both Compact Context Area and Metro Context Area unless noted otherwise. Units are in feet unless indicated otherwise. District Standard | I-1 | I-2 | I-3 | I-4 Maximum Height in all Districts Primary Building Height | 40 | 50 | N/A | N/A Primary Building Height Along a Transitional Yard | 22 | 22 | 35 | 35 Primary Building Height Along a Transitional Yard may increase 1 ft. per 1 ft. of additional side setback up to: | 40 | 50 | No limit | No limit Lot Minimum Street Frontage in Compact Context Area | 35 | 35 | 35 | 35 Minimum Street Frontage in Metro Context Area | 75 | 75 | 75 | 75 Minimum Setbacks in Compact Context Area [1] Fronts Along Expressways, Freeways, Primary and Secondary Arterials, Collector and Local Streets | 20 | 20 | 30 | 30 Front Transitional Yard | 30 | 30 | 40 | 50 Side and Rear Yard | 10 | 10 | 10 | 20 Side and Rear Transitional Yard | 30 | 30 | 40 | 50 Yard Abutting Railroad | [2] | [2] | [2] | [2] Minimum Setbacks in Metro Context Area [1] Fronts Along Expressways, Freeways, Primary and Secondary Arterials, Collector and Local Streets | 30 from proposed ROW | 30 from proposed ROW | 60 from proposed ROW | 60 from proposed ROW Front Transitional Yard | 100 | 100 | 150 | 200 Side and Rear Yard | 30 | 30 | 30 | 30 Side and Rear Transitional Yard | 50 | 50 | 100 | 150 Yard Abutting Railroad | [2] | [2] | [2] | [2] Notes: [1] Front setbacks are always measured from an existing right-of-way line unless otherwise indicated. [2] See also Section 744-204 Height exceptions and yard encroachments. G. Development Plan Districts. Dimensional standards for Development Plan Districts (PK-1, PK-2, HD-1, HD-2, UQ-1, UQ-2, SZ-1, and SZ-2) are set forth in Section 742-108, and the development plans approved for each of those Districts pursuant to Section 742-108. H. Special Use (SU) Districts. Dimensional standards for Special Use (SU) Districts are set forth in Section 742-109.

(G.O. 64, 2015, § 2; G.O. 37, 2018, § 9; G.O. 26, 2021, § 6; G.O. 23, 2023, § 7)

Ask a question about Indianapolis law

Corpus searches the Indianapolis sections it holds and shows the ones that match, with their citations. Free, no sign-in.