For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13.03.010 — International Property Maintenance Code adopted

Municipal Code of the City of Lafayette, Indiana (Codified through Ordinance of May 20, 2026. (Supp. No. 61, 11-26)) · Lafayette Municipal Code § 13.03.010

Corpus is an independent public-information project, not the official City of Lafayette website. Stable reference: corpuslaw.us/code/5042e3f4-4d57-4296-bcee-86682fe9ba4e

13.03.010 - International Property Maintenance Code adopted.

The International Property Maintenance Code of 2024 with certain modifications is adopted by the city as set forth below. CHAPTER 1 SCOPE AND ADMINISTRATION SECTION 101 GENERAL 101.1 Title. These regulations shall be known as the Property Maintenance Code of the City of Lafayette, hereinafter referred to as "this code." 101.2 Scope. The provisions of this code shall apply to all existing residential and nonresidential structures and all existing premises and constitute minimum requirements and standards for premises, structures, equipment and facilities for light, ventilation, space, heating, sanitation, protection from the elements, life safety, safety from fire and other hazards, and for safe and sanitary maintenance; the responsibility of owners, operators and occupants; the occupancy of existing structures and premises and penalties. 101.3 Purpose. The purpose of this code is to establish minimum requirements to provide a reasonable level of health, safety, property protection and general welfare insofar as they are affected by the continued occupancy and maintenance of structures and premises. Existing structures and premises that do not comply with these provisions shall be altered or repaired to provide a reasonable minimum level of health, safety and general welfare as required herein. 101.4 Severability. If a section, subsection, sentence, clause or phrase of this code is, for any reason, held to be unconstitutional, such decision shall not affect the validity of the remaining portions of this code. SECTION 102 APPLICABILITY 102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall govern. Where differences occur between provisions of this code and the referenced standards, the provisions of this code shall apply. Where, in a specific case, different sections of this code specify different requirements, the most restrictive shall govern. 102.2 Maintenance. Equipment, systems, devices and safeguards required by this code or a previous regulation or code under which the structure or premises was constructed, altered or repaired shall be maintained in good working order. An owner, owner's authorized agent, operator or occupant shall not cause any service, facility, equipment or utility that is required under this section to be removed from, shut off from or discontinued for any occupied dwelling, except for such temporary interruption as necessary while repairs or alterations are in progress. The requirements of this code are not intended to provide the basis for removal or abrogation of fire protection and safety systems and devices in existing structures. Except as otherwise specified herein, the owner or the owner's designated agent shall be responsible for the maintenance of buildings, structures and premises. 102.3 Application of other codes. Repairs, additions or alterations to a structure, or changes of occupancy, shall be done in accordance with the procedures and provisions of the Indiana Building Code. Nothing in this code shall be construed to cancel, modify or set aside any provision of the zoning code. 102.4 Existing remedies. The provisions in this code shall not be construed to abolish or impair existing remedies of the jurisdiction or its officers or agencies relating to the removal or demolition of any structure which is dangerous, unsafe and unsanitary. 102.5 Workmanship. Repairs, maintenance work, alterations or installations which are caused directly or indirectly by the enforcement of this code shall be executed and installed in a workmanlike manner and installed in accordance with the manufacturer's installation instructions. 102.6 Historic buildings. The provisions of this code shall not be mandatory for existing buildings or structures designated as historic buildings where such buildings or structures are judged by the enforcement authority to be safe and in the public interest of health, safety and welfare. 102.7 Referenced codes and standards. The codes and standards referenced in this code shall be those adopted by the State of Indiana, including all codes and regulations as adopted by the Indiana Department of Homeland Security, and shall collectively be referred to hereafter as the Indiana Building Code. 102.8 Requirements not covered by code. Requirements necessary for the strength, stability or proper operation of an existing structure or equipment, or for the public safety, health and general welfare, not specifically covered by this code, shall be determined by the enforcement authority. 102.9 Application of references. References to chapter or section numbers, or to provisions not specifically identified by number, shall be construed to refer to such chapter, section or provision of this code. 102.10 Other laws. The provisions of this code shall not be deemed to nullify any provisions of local, state or federal law. SECTION 103 DUTIES AND POWERS OF THE CODE OFFICIAL 103.1 General. The Enforcement Authority as defined under 13.05.010 is hereby authorized and directed to enforce the provisions of this code. 103.2 Determination of compliance. The enforcement authority shall have authority to determine compliance with this code, to render interpretations of this code and to adopt policies and procedures in order to clarify the application of this code's provisions. Such interpretations, policies and procedures: 1. Shall be in compliance with the intent and purpose of this code. 2. Shall not have the effect of waiving requirements specifically provided for in this code or other applicable codes and ordinances. 103.3 Notices and orders. The enforcement authority shall issue all necessary notices or orders to ensure compliance with this code. Orders must be issued in accordance with Lafayette Municipal Code 13.05.060. SECTION 104 VIOLATIONS 104.1 Unlawful acts. It shall be unlawful for a person, firm or corporation to be in conflict with or in violation of any of the provisions of this code. 104.2 Notice of violation. The enforcement authority shall serve a notice to the owner by regular first-class mail to the last know address of record. An order must be issued in accordance Lafayette Municipal Code 13.05.060. 104.3 Prosecution of violation. If an order is not complied with, the enforcement authority shall institute the appropriate in accordance with Lafayette Municipal Code Chapter 13.05. 104.4 Violation penalties. Whoever violates any provision of this chapter for which no penalty is otherwise provided, may be fined not more than one thousand dollars ($1,000.00). A separate offense shall be deemed committed on each day that a violation occurs or continues. 104.5 Abatement of violation. The imposition of the penalties herein prescribed shall not preclude the legal officer of the jurisdiction from instituting appropriate action to restrain, correct or abate a violation, or to prevent illegal occupancy of a building, structure or premises, or to stop an illegal act, conduct business or utilization of the building, structure or premises. SECTION 105 DEMOLITION 105.1 Application. All demolitions within the City of Lafayette shall comply with the requirements of this section. 105.2 Procedure for Ordered Demolitions. If the enforcement authority determines that a structure must be demolished, the procedures set forth in Indiana Code § 36-7-9 shall govern. 105.3 Other Rules and Regulations. Nothing in this section shall be construed to interfere with or limit the authority of the Indiana Department of Environmental Management, the Indiana Building Code, or any other applicable state or federal regulation. 105.4 Demolition Standards. 105.4.1 Permit Requirement. No building, structure, or portion thereof shall be demolished without first obtaining a demolition permit in accordance with Lafayette Municipal Code § 13.01.070. 105.4.2 Utility Disconnection. Prior to commencing demolition, the permit holder shall ensure that all utilities, including but not limited to water, sewer, gas, electric, and telecommunications, are properly disconnected and capped in compliance with utility provider requirements and city requirements. 105.4.3 Protection of Public Safety. The demolition site shall be secured at all times with appropriate fencing, barricades, and signage to prevent unauthorized access and to protect the public from hazards. 105.4.4 Dust and Debris Control. The permit holder shall implement measures to control dust, airborne particles, and debris during demolition, including the use of water spray or other suppression methods as required. 105.4.5 Waste Removal and Disposal. All debris, rubble, and waste materials resulting from demolition shall be removed from the site in a timely manner and disposed of in accordance with federal, state, and local laws. On-site burning of demolition debris is prohibited unless expressly authorized. 105.4.6 Site Restoration. Following demolition, the site shall be left in a clean, graded, and safe condition. Any open excavations shall be filled, compacted, and stabilized to prevent hazards or nuisances. CHAPTER 2 DEFINITIONS SECTION 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following terms shall, for the purposes of this code, have the meanings shown in this chapter. 201.2 Interchangeability. Words stated in the present tense include the future; words stated in the masculine gender include the feminine and neutral; the singular number includes the plural and the plural, the singular. 201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the Indiana Building Code and Indiana Fire Code. 201.4 Terms not defined. Where terms are not defined, through the methods authorized by this section, such terms shall have ordinarily accepted meanings such as the context implies. 201.5 Parts. Whenever the words "dwelling unit," "dwelling," "premises," "building," "rooming house," "rooming unit, "housekeeping unit" or "story" are stated in this code, they shall be construed as though they were followed by the words "or any part thereof." SECTION 202 GENERAL DEFINITIONS ANCHORED. Secured in a manner that provides positive connection. APPROVED. Acceptable to the enforcement authority. BASEMENT. That portion of a building that is partly or completely below grade. BATHROOM. A room containing plumbing fixtures including a bathtub or shower. BEDROOM. Any room or space used or intended to be used for sleeping purposes in either a dwelling or sleeping unit. ENFORCEMENT AUTHORITY. Defined in accordance with the meaning set forth in Lafayette Municipal Code 13.05.010. DETACHED. When a structural element is physically disconnected from another and that connection is necessary to provide a positive connection. DETERIORATION. To weaken, disintegrate, corrode, rust or decay and lose effectiveness. DWELLING UNIT. Defined in accordance with the meaning set forth in the Tippecanoe County Unified Zoning Ordinance. EASEMENT. Defined in accordance with the meaning set forth in the Tippecanoe County Unified Zoning Ordinance. EMERGENCY ESCAPE AND RESCUE OPENING. An operable exterior window, door or other similar device that provides for a means of escape and access for rescue in the event of an emergency. EXTERIOR PROPERTY. The open space on the premises and on adjoining property under the control of owners or operators of such premises. GARBAGE. Defined in accordance with the meaning set forth in Lafayette Municipal Code 6.07. 010. GUARD. A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to a lower level. HABITABLE SPACE. Space in a structure for living, sleeping, eating or cooking. Bathrooms, toilet rooms, closets, halls, storage or utility spaces, and similar areas are not considered habitable spaces. HISTORIC BUILDING. Defined in accordance with Lafayette Municipal Code 12.01.010. HOUSEKEEPING UNIT. Defined in accordance with the meaning set forth in the Tippecanoe County Unified Zoning Ordinance. INFESTATION. The presence, within or contiguous to, a structure or premises of insects, rodents, vermin or other pests. LABELED. Equipment, materials or products to which has been affixed a label, seal, symbol or other identifying mark of a nationally recognized testing laboratory, approved agency or other organization concerned with product evaluation that maintains periodic inspection of the production of the above-labeled items and by whose labeling indicates either that the equipment, material or product meets identified standards or has been tested and found suitable for a specified purpose. LET FOR OCCUPANCY OR LET. To permit, provide or offer possession or occupancy of a dwelling, dwelling unit, rooming unit, building, premise or structure by a person who is or is not the legal owner of record thereof, pursuant to a written or unwritten lease, agreement or license, or pursuant to a recorded or unrecorded agreement of contract for the sale of land. OCCUPANCY. The purpose for which a building or portion thereof is utilized or occupied. OCCUPANT. Any individual living or sleeping in a building; or having possession of a space within a building. OPENABLE AREA. That part of a window, skylight or door which is available for unobstructed ventilation and which opens directly to the outdoors. OPERATOR. Any person who has charge, care or control of a structure or premises that is let or offered for occupancy. OWNER. Defined in accordance with the meaning set forth in Lafayette Municipal Code 13.05. 010. PERSON. An individual, corporation, partnership or any other group acting as a unit. PEST ELIMINATION. The control and elimination of insects, rodents or other pests by eliminating their harborage places; by removing or making inaccessible materials that serve as their food or water; by other approved pest elimination methods. PREMISES. A lot, plot or parcel of land, easement or public way, including any structures thereon. PUBLIC WAY. Any street, alley or other parcel of land that: is open to the outside air; leads to a street; has been deeded, dedicated or otherwise permanently appropriated to the public for public use; and has a clear width and height of not less than 10 feet (3048 mm). ROOMING HOUSE. A building arranged or occupied for lodging, with or without meals, for compensation and not occupied as a one- or two-family dwelling. ROOMING UNIT. Any room or group of rooms forming a single habitable unit occupied or intended to be occupied for sleeping or living, but not for cooking purposes. RUBBISH. Defined in accordance with the meaning set forth in Lafayette Municipal Code 6.07.010. SLEEPING UNIT. A room or space in which people sleep, which can also include permanent provisions for living, eating and either sanitation or kitchen facilities, but not both. Such rooms and spaces that are also part of a dwelling unit are not sleeping units. STRUCTURE. That which is built or constructed. TENANT. A person, corporation, partnership or group, whether or not the legal owner of record, occupying a building or portion thereof as a unit. TOILET ROOM. A room containing a water closet or urinal but not a bathtub or shower. ULTIMATE DEFORMATION. The deformation at which failure occurs and that shall be deemed to occur if the sustainable load reduces to 80 percent or less of the maximum strength. VENTILATION. The natural or mechanical process of supplying conditioned or unconditioned air to, or removing such air from, any space. WORKMANLIKE. Executed in a skilled manner; e.g., generally plumb, level, square, in line, undamaged, and without marring adjacent work. YARD. An open space on the same lot with a structure. CHAPTER 3 GENERAL SECTION 301 GENERAL 301.1 Scope. The provisions of this chapter shall govern the minimum conditions and the responsibilities of persons for maintenance of structures, equipment and exterior property. 301.2 Responsibility. The owner of the premises shall maintain the structures and exterior property in compliance with these requirements and the code under which the building was constructed, except as otherwise provided for in this code. The owner or owner's agent shall be responsible to ensure that any repairs, additions or alterations to the building or portion thereof are performed or constructed in accordance with this code. A person shall not occupy as owner-occupant or permit another person to occupy premises which are not in a sanitary and safe condition, and which do not comply with the requirements of this chapter. 301.3 Vacant and abandoned structures and land. All vacant structures and premises thereof must be maintained consistent with Lafayette Municipal Code Chapter 13.05. Vacant land shall be maintained in a clean, safe, secure and sanitary condition as provided herein so as not to cause a blighting problem or adversely affect the public health or safety. SECTION 302 EXTERIOR PROPERTY AREAS 302.1 Sanitation. All exterior property and premises shall be maintained in a clean, safe and sanitary condition. 302.2 Grading and drainage. Premises shall be graded and maintained to prevent the erosion of soil and to prevent the accumulation of stagnant water thereon, or within any structure located thereon. Exception: Approved retention areas and reservoirs. 302.3 Sidewalks and driveways. Sidewalks, walkways, stairs, driveways, parking spaces and similar areas shall be kept in a proper state of repair, and maintained free from hazardous conditions. 302.4 Rodent harborage. Structures and exterior property shall be kept free from rodent harborage and infestation. Where rodents are found, they shall be promptly exterminated by approved processes that will not be injurious to human health. After pest elimination, proper precautions shall be taken to eliminate rodent harborage and prevent reinfestation. 302.5 Exhaust vents. Pipes, ducts, conductors, fans or blowers shall not discharge gases, steam, vapor, hot air, grease, smoke, odors or other gaseous or particulate wastes directly on abutting or adjacent public or private property or that of another tenant. 302.6 Accessory structures. Accessory structures, including detached garages, fences and walls, shall be maintained structurally sound and in good repair. 302.7 Removal of graffiti. (a) Definition. The term "graffiti" for purposes of this section, shall mean any unauthorized inscription or representation, on a building, structure, wall, sign, fence, sidewalk, pavement, post, stone, tree or other object or structure, of any symbol, diagram, letter, word, numeral, emblem, picture, character, or combination thereof by carving, application of paint or other substance other than as permitted by this code. (b) Removal required. It shall be the duty of the owner of the building, structure, wall, dumpster, or other personal property upon which any graffiti has been placed to remove, cover or eradicate the graffiti. When graffiti is found to be on private property, the City Engineer, or their designee, shall notify the property owner in writing of the graffiti and request its removal within fifteen (15) days. For good cause shown, the owner may be given additional time to meet the removal requirements without being charged with a violation of this section. (c) Removal by city authorized. In addition to any fine which may be imposed, if the owner fails to remove, cover or otherwise eradicate the graffiti within fifteen (15) days from the issuance of the notice, or such later date as the owner may be allowed, the city or its authorized agent may enter upon the property and remove such graffiti by any means necessary, and the cost of removal shall be collected from the owner of the property. (d) Lien for costs of removal incurred by city. Within 10 days, following the removal by the City of any graffiti from private property, the City shall send the property owner a Notice of Intent To Assess Costs detailing the cost remaining unpaid by the property owner, and within thirty (30) days of the date of the removal of the graffiti, said cost shall become a lien upon the real estate affected, unless modified in the Appeals Process provided in section (e). A city representative or agent shall report the costs to the City Controller, who shall certify the costs to the County Auditor. The Auditor shall place the same on the tax duplicate as a charge against the owner of the real estate, to be collected by the County Treasurer with the state, county and municipal taxes assessed against the owner's real estate at the regular time for paying the taxes. (e) Appeal Rights. The owner of the property may seek relief from the cost of the removal and abatement of the graffiti as provided in sections (c) and (d) by making a written request to the City Engineer, or their designee, providing all reasons and explanations justifying any modification or waiver of those cost. Each written request must be made within 10 days after receiving the Notice of Intent to Assess Cost. The City Engineer, or their designee, shall within 5 days of the receipt of an appeal, either waive, modify or reaffirm those costs and provide a written statement of said determination to the property owner with a copy to the Board of Works and Public Safety of the City of Lafayette. The property owner may request a Hearing and review of the City Engineer's decision by filing a written request with the Board of Works and Public Safety on or before 10 days after receiving the City Engineer's determination. The Board of Public Works and Safety shall at their next scheduled meeting make a final determination of the assessment of cost and placement of lien. (f) Recovery of cost from person responsible for placing graffiti. The cities' exercise of the remedies provided in this Ordinance shall not prevent the owner from recovery, through civil suit or otherwise, the cost of removal or other reparation from the person responsible for placing the graffiti on his property. (g) Penalty. Whoever violates any provision of this chapter may, in addition to payment of the costs incurred by the city to remove the graffiti, be fined not more than fifty dollars ($50.00). A separate offense shall be deemed committed on each day that a violation occurs or continues. SECTION 303 SWIMMING POOLS, SPAS AND HOT TUBS 303.1 Swimming pools. Swimming pools shall be maintained in a clean and sanitary condition, and in good repair. 303.2 Enclosures. As required by Lafayette Municipal Code 11.05.010. SECTION 304 EXTERIOR STRUCTURE 304.1 General. The exterior of a structure shall be maintained in good repair, structurally sound and sanitary so as not to pose a threat to the public health, safety or welfare. 304.1.1 Potentially unsafe conditions. The following conditions shall be considered to be potentially unsafe, shall be assessed and shall be addressed in compliance with the Indiana Building Code: 1. Structural members have deterioration or distress that appears to reduce their load carrying capacity. 2. The anchorage of the floor or roof to walls or columns, and of walls and columns to foundations has deterioration or distress that appears to reduce its load-carrying capacity. 3. Structures or components thereof have deterioration or distress that appears to reduce their load-carrying capacity. 4. Siding and masonry joints including joints between the building envelope and the perimeter of windows, doors and skylights are not maintained, weather resistant or watertight. 5. Foundation systems that are not firmly supported by footings, are not plumb and free from open cracks and breaks, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects. 6. Exterior walls that are not anchored to supporting and supported elements or are not plumb and free of holes, cracks or breaks and loose or rotting materials, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects. 7. Roofing or roofing components that have defects that admit rain, roof surfaces with inadequate drainage, or any portion of the roof framing that is not in good repair with signs of deterioration, fatigue or without proper anchorage and incapable of supporting all nominal loads and resisting all load effects. 8. Flooring and flooring components with defects that affect serviceability or flooring components that show signs of deterioration or fatigue, are not properly anchored or are incapable of supporting all nominal loads and resisting all load effects. 9. Veneer, cornices, belt courses, corbels, trim, wall facings and similar decorative features not properly or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects. 10. Overhang extensions or projections including, but not limited to, trash chutes, canopies, marquees, signs, awnings, fire escapes, standpipes and exhaust ducts not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects. 11. Exterior stairs, decks, porches, balconies and all similar appurtenances attached thereto, including guards and handrails, are not structurally sound, not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects. 12. Chimneys, cooling towers, smokestacks and similar appurtenances not structurally sound or not properly anchored, or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects. 304.2 Protective treatment. Exterior surfaces, including but not limited to, doors, door and window frames, cornices, porches, trim, balconies, decks and fences, shall be maintained in good condition. Exterior wood surfaces, other than decay-resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. Peeling, flaking and chipped paint shall be eliminated and surfaces repainted. Siding and masonry joints, as well as those between the building envelope and the perimeter of windows, doors and skylights, shall be maintained weather resistant and watertight. Metal surfaces subject to rust or corrosion shall be coated to inhibit such rust and corrosion, and surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion. Oxidation stains shall be removed from exterior surfaces. Surfaces designed for stabilization by oxidation are exempt from this requirement. 304.3 Premises identification. Buildings shall have approved address numbers placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be not less than 4 inches (102 mm) in height with a minimum stroke width of 0.5 inch (12.7 mm). 304.4 Structural members. Structural members shall be maintained free from deterioration, and shall be capable of safely supporting the imposed dead and live loads. 304.5 Foundation walls. Foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests. 304.6 Exterior walls. Exterior walls shall be free from holes, breaks, and loose or rotting materials; and maintained weatherproof and properly surface coated where required to prevent deterioration. 304.7 Roofs and drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance. 304.8 Decorative features. Cornices, belt courses, corbels, terra cotta trim, wall facings and similar decorative features shall be maintained in good repair with proper anchorage and in a safe condition. 304.9 Overhang extensions. Overhang extensions including, but not limited to, canopies, marquees, signs, metal awnings, fire escapes, standpipes and exhaust ducts shall be maintained in good repair and be properly anchored so as to be kept in a sound condition. Where required, all exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weathercoating materials, such as paint or similar surface treatment. 304.10 Stairways, decks, porches and balconies. Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads. 304.11 Chimneys and towers. Chimneys, cooling towers, smoke stacks, and similar appurtenances shall be maintained structurally safe and sound, and in good repair. Exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment. 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. 304.13 Window, skylight and door frames. Every window, skylight, door and frame shall be kept in sound condition, good repair and weathertight. 304.13.1 Glazing. Glazing materials shall be maintained free from cracks and holes. 304.13.2 Openable windows. Every window, other than a fixed window, shall be easily openable and capable of being held in position by window hardware. 304.14 Insect screens. During the period from April 1 to December 1, every door, window and other outside opening required for ventilation of habitable rooms, food preparation areas, food service areas, or any areas where products to be included or utilized in food for human consumption are processed, manufactured, packaged or stored, shall be supplied with approved tightly fitting screens of minimum 16 mesh per inch (16 mesh per 25 mm), and every screen door used for insect control shall have a self-closing device in good working condition. Exception: Screens shall not be required where other approved means, such as air curtains or insect repellent fans, are employed. 304.15 Doors. Exterior doors, door assemblies, operator systems if provided, and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3. 304.16 Basement hatchways. Every basement hatchway shall be maintained to prevent the entrance of rodents, rain and surface drainage water. 304.17 Guards for basement windows. Every basement window that is openable shall be supplied with rodent shields, storm windows or other approved protection against the entry of rodents. 304.18 Building security. Doors, windows or hatchways for dwelling units, room units or housekeeping units shall be provided with devices designed to provide security for the occupants and property within. 304.18.1 Doors. Doors providing access to an individual dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be where equipped with a deadbolt lock, the deadbolt shall be designed to be readily openable from the side from which egress is to be made without the need for keys, special knowledge or effort and shall have a minimum lock throw of 1 inch (25 mm). Such deadbolt locks shall be installed according to the manufacturer's specifications and maintained in good working order. For the purpose of this section, a sliding bolt shall not be considered an acceptable deadbolt lock. 304.18.2 Windows. Operable windows located in whole or in part within 6 feet (1828 mm) above ground level or a walking surface below that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a window sash locking device. 304.18.3 Basement hatchways. Basement hatchways that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with devices that secure the units from unauthorized entry. 304.19 Gates. Exterior gates, gate assemblies, operator systems if provided, and hardware shall be maintained in good condition. Latches at all entrances shall tightly secure the gates. SECTION 305 INTERIOR STRUCTURE 305.1 General. The interior of a structure and equipment therein shall be maintained in good repair, structurally sound and in a sanitary condition. Every occupant shall keep that part of the structure which such occupant occupies or controls in a clean and sanitary condition. Every owner of a structure containing a rooming house, a hotel, a dormitory, two or more dwelling units or two or more nonresidential occupancies, shall maintain, in a clean and sanitary condition, the shared or public areas of the structure and exterior property. 305.1.1 Potentially unsafe conditions. The following conditions shall be considered to be potentially unsafe, shall be assessed and addressed in compliance with this code: 1. Structural members have deterioration or distress that appears to reduce their load carrying capacity. 2. The anchorage of the floor or roof to walls or columns, and of walls and columns to foundations has deterioration or distress that appears to reduce its load-carrying capacity. 3. Structures or components thereof have deterioration or distress that appears to reduce their load-carrying capacity. 4. Stairs, landings, balconies and all similar walking surfaces, including guards and handrails, are not structurally sound, not properly anchored or are anchored with connections not capable of supporting all nominal loads and resisting all load effects. 5. Foundation systems that are not firmly supported by footings are not plumb and free from open cracks and breaks, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects. 305.2 Structural members. Structural members shall be maintained structurally sound and be capable of supporting the imposed loads. 305.3 Interior surfaces. Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 305.4 Stairs and walking surfaces. Every stair, ramp, landing, balcony, porch, deck or other walking surface shall be maintained in sound condition and good repair. 305.5 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. 305.6 Interior doors. Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs, headers or tracks as intended by the manufacturer of the attachment hardware. SECTION 306 COMPONENT SERVICEABILITY 306.1 General. The components of a structure and equipment therein shall be maintained in good repair, structurally sound and in a sanitary condition. 306.1.1 Potentially unsafe conditions. Where any of the following conditions cause the component or system to be beyond its limit state, the component or system shall be considered to be unsafe and shall be addressed in compliance with the Indiana Building Code: 1. Soils that have been subjected to any of the following conditions: 1.1. Collapse of footing or foundation system. 1.2. Damage to footing, foundation, concrete or other structural element due to soil expansion. 1.3. Adverse effects to the design strength of footing, foundation, concrete or other structural element due to a chemical reaction from the soil. 1.4. Inadequate soil as determined by a geotechnical investigation. 1.5. Where the allowable bearing capacity of the soil is in doubt. 1.6. Adverse effects to the footing, foundation, concrete or other structural element due to the ground water table. 2. Concrete that has been subjected to any of the following conditions: 2.1. Deterioration. 2.2. Ultimate deformation. 2.3. Fractures. 2.4. Fissures. 2.5. Spalling. 2.6. Exposed reinforcement. 2.7. Detached, dislodged or failing connections. 3. Aluminum that has been subjected to any of the following conditions: 3.1. Deterioration. 3.2. Corrosion. 3.3. Elastic deformation. 3.4. Ultimate deformation. 3.5. Stress or strain cracks. 3.6. Joint fatigue. 3.7. Detached, dislodged or falling connections. 4. Masonry that has been subjected to any of the following conditions: 4.1. Deterioration. 4.2. Ultimate deformation. 4.3. Fractures in masonry or mortar joints. 4.4. Fissures in masonry or mortar joints. 4.5. Spalling. 4.6. Exposed reinforcement. 4.7. Detached, dislodged or failing connections. 5. Steel that has been subjected to any of the following conditions: 5.1. Deterioration. 5.2. Elastic deformation. 5.3. Ultimate deformation. 5.4. Metal fatigue. 5.5. Detached, dislodged or falling connections. 6. Wood that has been subjected to any of the following conditions: 6.1. Ultimate deformation. 6.2. Deterioration. 6.3. Damage from insects, rodents and other vermin. 6.4. Fire damage beyond charring. 6.5. Significant splits and checks. 6.6. Horizontal shear cracks. 6.7. Vertical shear cracks. 6.8. Inadequate support. 6.9. Detached, dislodged or failing connections. 6.10. Excessive cutting and notching. SECTION 307 HANDRAILS AND GUARDRAILS 307.1 Handrails. Stairs having more than four risers shall have a handrail on one side of the stair. 307.1.1 Height. Handrails shall be not less than 30 inches (762 mm) in height or more than 42 inches (1067 mm) in height measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces. 307.2 Guards. Guards shall be provided along open-sided walking surfaces, including balconies, porches, decks, stairs, ramps and landings, that are more than 30 inches (762 mm) above the floor or grade below. Exception: Guards shall not be required where exempted by the adopted building code. 307.2.1 Height. Guards shall be not less than 30 inches (762 mm) high. SECTION 308 RUBBISH AND GARBAGE 308.1 Accumulation of rubbish or garbage. Exterior property and premises, and the interior of every structure, shall be free from any accumulation of rubbish or garbage. 308.2 Disposal of rubbish and garbage. All garbage and rubbish shall be disposed of in accordance with Lafayette Municipal Code 6.07. SECTION 309 PEST ELIMINATION 309.1 Infestation. Structures shall be kept free from insect and rodent infestation. Structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health. After pest elimination, proper precautions shall be taken to prevent reinfestation. 309.2 Owner. The owner of any structure shall be responsible for pest elimination within the structure. SECTION 310 ACCESSIBILITY 310.1 General. A facility that is required to be accessible shall be maintained accessible during occupancy. 310.1.1 Maintenance. The accessible features of a facility shall be maintained in good repair, in a clean, structurally sound and sanitary condition, and free from impediments to accessibility. CHAPTER 4 LIGHT, VENTILATION AND OCCUPANCY LIMITATIONS SECTION 401 GENERAL 401.1 Scope. The provisions of this chapter shall govern the minimum conditions and standards for light, ventilation and space for occupying a structure. 401.2 Responsibility. The owner of the structure shall provide and maintain light, ventilation and space conditions in compliance with these requirements. A person shall not occupy as owner-occupant, or permit another person to occupy, any premises that do not comply with the requirements of this chapter. 401.3 Alternative devices. In lieu of the means for natural light and ventilation herein prescribed, artificial light or mechanical ventilation complying with the Indiana Building Code shall be permitted. SECTION 402 LIGHT 402.1 Habitable spaces. Every habitable space shall have not less than one window of approved size facing directly to the outdoors or to a court. The minimum total glazed area for every habitable space shall be 8 percent of the floor area of such room. Wherever walls or other portions of a structure face a window of any room and such obstructions are located less than 3 feet (914 mm) from the window and extend to a level above that of the ceiling of the room, such window shall not be deemed to face directly to the outdoors nor to a court and shall not be included as contributing to the required minimum total window area for the room. Exception: Where natural light for rooms or spaces without exterior glazing areas is provided through an adjoining room, the unobstructed opening to the adjoining room shall be not less than 8 percent of the floor area of the interior room or space, but not less than 25 square feet (2.33 m2), whichever is greater. The exterior glazing area shall be based on the total floor area being served. 402.2 Common halls and stairways. Every common hall and stairway in residential occupancies, other than in one-and two-family dwellings, shall be lighted at all times with not less than a 60-watt standard incandescent light bulb for each 200 square feet (19 m 2 ) of floor area or equivalent illumination, provided that the spacing between lights shall not be greater than 30 feet (9144 mm). In other than residential occupancies, interior and exterior means of egress, stairways shall be illuminated at all times the building space served by the means of egress is occupied with not less than 1 footcandle (11 lux) at floors, landings and treads. 402.3 Other spaces. Other spaces shall be provided with natural or artificial light sufficient to permit the maintenance of sanitary conditions, and the safe occupancy of the space and utilization of the appliances, equipment and fixtures. SECTION 403 VENTILATION 403.1 Habitable spaces. Every habitable space shall have not less than one openable window. The total openable area of the window in every room shall be equal to not less than 45 percent of the minimum glazed area required in Section 402.1. Exception: Where rooms and spaces without openings to the outdoors are ventilated through an adjoining room, the unobstructed opening to the adjoining room shall be not less than 8 percent of the floor area of the interior room or space, but not less than 25 square feet (2.33 m 2 ). The ventilation openings to the outdoors shall be based on a total floor area being ventilated. 403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section 403.1, except that a window shall not be required in such spaces equipped with a mechanical ventilation system. Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated. 403.3 Cooking facilities. Unless approved through the certificate of occupancy, cooking shall not be permitted in any rooming unit or dormitory unit, and a cooking facility or appliance shall not be permitted to be present in a rooming unit or dormitory unit. Exceptions: 1. Where specifically approved in writing by the enforcement authority. 2. Devices such as coffee pots and microwave ovens shall not be considered cooking appliances. 403.4 Process ventilation. Where injurious, toxic, irritating or noxious fumes, gases, dusts or mists are generated, a local exhaust ventilation system shall be provided to remove the contaminating agent at the source. Air shall be exhausted to the exterior and not be recirculated to any space. 403.5 Clothes dryer exhaust. Clothes dryer exhaust systems shall be independent of all other systems and shall be exhausted outside the structure in accordance with the manufacturer's instructions. Exception: Listed and labeled condensing (ductless) clothes dryers. SECTION 404 OCCUPANCY LIMITATIONS 404.1 Privacy. Dwelling units, hotel units, housekeeping units, rooming units and dormitory units shall be arranged to provide privacy and be separate from other adjoining spaces. 404.2 Minimum room widths. A habitable room, other than a kitchen, shall be not less than 7 feet (2134 mm) in any plan dimension. Kitchens shall have a clear passageway of not less than 3 feet (914 mm) between counterfronts and appliances or counterfronts and walls. 404.3 Minimum ceiling heights. Habitable spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a minimum clear ceiling height of 7 feet (2134 mm). Exceptions: 1. In one- and two-family dwellings, beams or girders spaced not less than 4 feet (1219 mm) on center and projecting not greater than 6 inches (152 mm) below the required ceiling height. 2. Basement rooms in one- and two-family dwellings occupied exclusively for laundry, study or recreation purposes, having a minimum ceiling height of 6 feet 8 inches (2033 mm) with a minimum clear height of 6 feet 4 inches (1932 mm) under beams, girders, ducts and similar obstructions. 3. In one- and two-family dwellings, rooms occupied exclusively for bathrooms, toilet rooms and laundry rooms having a minimum ceiling height of 6 feet 8 inches (2033 mm). 4. Rooms occupied exclusively for sleeping, study or similar purposes and having a sloped ceiling over all or part of the room, with a minimum clear ceiling height of 7 feet (2134 mm) over not less than one-third of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a minimum clear ceiling height of 5 feet (1524 mm) shall be included. 404.4 Habitable room requirements. Every habitable room shall comply with the requirements of Sections 404.4.1 through 404.4.5. 404.4.1 Room area. Every habitable room shall contain not less than 70 square feet (6.5 m 2 ) and every bedroom occupied by more than one person shall contain not less than 50 square feet (4.6 m 2 ) of floor area for each occupant thereof. 404.4.2 Access from bedrooms. Bedrooms shall not constitute the only means of access to other bedrooms or habitable spaces and shall not serve as the only means of egress from other habitable spaces. Exception: Units that contain fewer than two bedrooms. 404.4.3 Water closet accessibility. Every bedroom shall have access to not less than one water closet and one lavatory without passing through another bedroom. Every bedroom in a dwelling unit shall have access to not less than one water closet and lavatory located in the same story as the bedroom or an adjacent story. 404.4.4 Prohibited occupancy. Kitchens and nonhabitable spaces shall not be used for sleeping purposes. 404.4.5 Other requirements. Bedrooms shall comply with the applicable provisions of this code including, but not limited to, the light, ventilation, room area, ceiling height and room width requirements of this chapter; the plumbing facilities and water-heating facilities requirements of Chapter 5; the heating facilities and electrical receptacle requirements of Chapter 6; and the smoke detector and emergency escape requirements of Chapter 7. 404.5 Overcrowding. Dwelling units shall not be occupied by more occupants than permitted by the minimum area requirements of Table 404.5 Table 404.5 MINIMUM AREA REQUIREMENTS MINIMUM AREA IN SQUARE FEET Space | 1-2 occupants | 3-5 occupants | 6 or more occupants Living room a.b. | 120 | 120 | 150 Dining room a.b. | No requirement | 80 | 100 Bedrooms | Shall comply with Section 404.4.1 For SI: 1 square foot = 0.0929 m2. a. See Section 404.5.2 for combined living room/dining room spaces. b. See Section 404.5.1 for limitations on determining the minimum occupancy area for sleeping purposes. 404.5.1 Sleeping area. The minimum occupancy area required by Table 404.5 shall not be included as a sleeping area in determining the minimum occupancy area for sleeping purposes. Sleeping areas shall comply with Section 404.4. 404.5.2 Combined spaces. Combined living room and dining room spaces shall comply with the requirements of Table 404.5 if the total area is equal to that required for separate rooms and if the space is located so as to function as a combination living room/dining room. 404.6 Efficiency unit. Nothing in this section shall prohibit an efficiency living unit from meeting the following requirements: 1. A unit occupied by not more than one occupant shall have a minimum clear floor area of 120 square feet (11.2 m 2 ). A unit occupied by not more than two occupants shall have a minimum clear floor area of 220 190 square feet (20.4 17.7 m 2 ). A unit occupied by three occupants shall have a minimum clear floor area of 320 260 square feet (29.724.2 m 2 ). These required areas shall be exclusive of the areas required by Items 2 and 3. 2. The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities, each having a minimum clear working space of 30 inches (762 mm) in front. Light and ventilation conforming to this code shall be provided. 3. The unit shall be provided with a separate bathroom containing a water closet, lavatory and bathtub or shower. 4. The maximum number of occupants shall be three. 404.7 Food preparation. Spaces to be occupied for food preparation purposes shall contain suitable space and equipment to store, prepare and serve foods in a sanitary manner. There shall be adequate facilities and services for the sanitary disposal of food wastes and refuse, including facilities for temporary storage. CHAPTER 5 PLUMBING FACILITIES AND FIXTURE REQUIREMENTS SECTION 501 GENERAL 501.1 Scope. The provisions of this chapter shall govern the minimum plumbing systems, facilities and plumbing fixtures to be provided. 501.2 Responsibility. The owner of the structure shall provide and maintain such plumbing facilities and plumbing fixtures in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any structure or premises that does not comply with the requirements of this chapter. SECTION 502 REQUIRED FACILITIES 502.1 Dwelling units. Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink that shall be maintained in a sanitary, safe working condition. The lavatory shall be placed in the same room as the water closet or located in close proximity to the door leading directly into the room in which such water closet is located. A kitchen sink shall not be used as a substitute for the required lavatory. 502.2 Rooming houses. Not less than one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. 502.3 Hotels. Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each 10 occupants. 502.4 Employees' facilities. Not less than one water closet, one lavatory and one drinking facility shall be available to employees. 502.5 Public toilet facilities. Public toilet facilities shall be maintained in a safe, sanitary and working condition in accordance with the Indiana Building Code. Except for periodic maintenance or cleaning, public access and use shall be provided to the toilet facilities at all times during occupancy of the premises. SECTION 503 TOILET ROOMS 503.1 Privacy. Toilet rooms and bathrooms shall provide privacy and shall not constitute the only passageway to a hall or other space, or to the exterior. A door and interior locking device shall be provided for all common or shared bathrooms and toilet rooms in a multiple dwelling. 503.2 Location. Toilet rooms and bathrooms serving hotel units, rooming units or dormitory units or housekeeping units, shall have access by traversing not more than one flight of stairs and shall have access from a common hall or passageway. 503.3 Floor surface. In other than dwelling units, every toilet room floor shall be maintained to be a smooth, hard, nonabsorbent surface to permit such floor to be easily kept in a clean and sanitary condition. SECTION 504 PLUMBING SYSTEMS AND FIXTURES 504.1 General. Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition. 504.2 Fixture clearances. Plumbing fixtures shall have adequate clearances for usage and cleaning. 504.3 Plumbing system hazards. Where it is found that a plumbing system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, inadequate venting, cross connection, backsiphonage, improper installation, deterioration or damage or for similar reasons, the enforcement authority shall require the defects to be corrected to eliminate the hazard. SECTION 505 WATER SYSTEM 505.1 General. Every sink, lavatory, bathtub or shower, drinking fountain, water closet or other plumbing fixture shall be properly connected to either a public water system or to an approved private water system. Kitchen sinks, lavatories, laundry facilities, bathtubs and showers shall be supplied with hot or tempered and cold running water in accordance with the Indiana Building Code. 505.2 Contamination. The water supply shall be maintained free from contamination, and all water inlets for plumbing fixtures shall be located above the flood-level rim of the fixture. Shampoo basin faucets, janitor sink faucets, and other hose bibs or faucets to which hoses are attached and left in place, shall be protected by an approved atmospheric-type vacuum breaker or an approved permanently attached hose connection vacuum breaker. 505.3 Supply. The water supply system shall be installed and maintained to provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks. 505.4 Water heating facilities. Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 110 degrees F (43 degrees C.). A gas-burning water heater shall not be located in any bathroom, toilet room, bedroom or other occupied room normally kept closed, unless adequate combustion air is provided. An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters. 505.5 Nonpotable water reuse systems. Nonpotable water reuse systems and rainwater collection and conveyance systems shall be maintained in a safe and sanitary condition. Where such systems are not properly maintained, the systems shall be repaired to provide for safe and sanitary conditions, or the system shall be abandoned in accordance with Section 505.5.1. 505.5.1 Abandonment of systems. Where a nonpotable water reuse system or a rainwater collection and distribution system is not maintained or the owner ceases use of the system, the system shall be abandoned in accordance with Indiana Building Code. SECTION 506 SANITARY DRAINAGE SYSTEM 506.1 General. Plumbing fixtures shall be properly connected to either a public sewer system or to an approved private sewage disposal system. 506.2 Maintenance. Every plumbing stack, vent, waste and sewer line shall function properly and be kept free from obstructions, leaks and defects. SECTION 507 STORM DRAINAGE 507.1 General. Drainage of roofs and paved areas, yards and courts, and other open areas on the premises shall not be discharged in a manner that creates a public nuisance. CHAPTER 6 MECHANICAL AND ELECTRICAL REQUIREMENTS SECTION 601 GENERAL 601.1 Scope. The provisions of this chapter shall govern the minimum mechanical and electrical facilities and equipment to be provided. 601.2 Responsibility. The owner of the structure shall provide and maintain mechanical and electrical facilities and equipment in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any premises that does not comply with the requirements of this chapter. SECTION 602 HEATING FACILITIES 602.1 Facilities required. Heating facilities shall be provided in structures as required by this section. 602.2 Residential occupancies. The owner of the dwelling shall provide heating facilities capable of maintaining a room temperature of 68 degrees F (20 degrees C) in all habitable rooms, bathrooms and toilet rooms based on the winter outdoor design temperature. Cooking appliances shall not be used, nor shall portable unvented fuel-burning space heaters be used, as a means to provide required heating. The installation of one or more portable space heaters shall not be used to achieve compliance with this section. 602.3 Heat supply. Every owner and operator of any building who rents, leases, or lets one or more dwelling units or sleeping units, under terms either express or implied to furnish heat, shall supply heat during periods of cold weather as necessary to maintain a minimum temperature of not less than 68°F (20°C) in all habitable rooms, bathrooms, and toilet rooms. 602.4 Occupiable workspaces. Indoor occupiable workspaces shall be supplied with heat during periods of cold weather as necessary to maintain temperature of not less than 65°F (18°C) during the period the spaces are occupied. Exceptions: 1. Processing, storage and operation areas that require cooling or special temperature conditions. 2. Areas in which persons are primarily engaged in vigorous physical activities. 602.5 Room temperature measurement. The required room temperatures shall be measured 3 feet (914 mm) above the floor near the center of the room and 2 feet (610 mm) inward from the center of each exterior wall. SECTION 603 MECHANICAL EQUIPMENT 603.1 Mechanical equipment and appliances. Mechanical equipment, appliances, fireplaces, solid fuel-burning appliances, cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition, and shall be capable of performing the intended function. 603.2 Removal of combustion products. Fuel-burning equipment and appliances shall be connected to an approved chimney or vent. Exception: Fuel-burning equipment and appliances that are labeled for unvented operation. 603.3 Clearances. Required clearances to combustible materials shall be maintained. 603.4 Safety controls. Safety controls for fuel-burning equipment shall be maintained in effective operation. 603.5 Combustion air. A supply of air for complete combustion of the fuel and for ventilation of the space containing the fuel-burning equipment shall be provided for the fuel-burning equipment. 603.6 Energy conservation devices. Devices intended to reduce fuel consumption by attachment to a fuel-burning appliance, to the fuel supply line thereto, or to the vent outlet or vent piping therefrom, shall not be installed unless labeled for such purpose and the installation is specifically approved. SECTION 604 ELECTRICAL FACILITIES 604.1 Facilities required. Every occupied building shall be provided with an electrical system in compliance with the requirements of this section and Section 605. 604.2 Service. The size and usage of appliances and equipment shall serve as a basis for determining the need for additional facilities in accordance with Indiana Building Code. Dwelling units shall be served by a three-wire, 120/240 volt, single-phase electrical service having a minimum rating of 60 amperes. 604.3 Electrical system hazards. Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, insufficient receptacle and lighting outlets, improper wiring or installation, deterioration or damage, or for similar reasons, the enforcement authority shall require the defects to be corrected to eliminate the hazard in accordance with Indiana Building Code. SECTION 605 ELECTRICAL EQUIPMENT 605.1 Installation. Electrical equipment, wiring and appliances shall be properly installed and maintained in a safe and approved manner. 605.2 Receptacles. Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location. 605.3 Luminaires. Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain not less than one electric luminaire. Pool and spa luminaires over 15 V shall have ground fault circuit interrupter protection. 605.4 Wiring. Flexible cords shall not be used for permanent wiring, or for running through doors, windows, or cabinets, or concealed within walls, floors, or ceilings. SECTION 606 DUCT SYSTEMS 606.1 General. Duct systems shall be maintained free of all obstructions and shall be capable of performing the required function. 606.2 Clothes dryer exhaust duct system maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall undergo periodic removal of accumulations of lint in accordance with the manufacturer's operating instructions to prevent obstruction of exhaust air and products of combustion. CHAPTER 7 FIRE SAFETY REQUIREMENTS SECTION 701 GENERAL 701.1 Scope. The provisions of this chapter shall govern the minimum conditions and standards for fire safety relating to structures and exterior premises, including fire safety facilities and equipment to be provided. 701.2 Responsibility. The owner of the premises shall provide and maintain such fire safety facilities and equipment in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any premises that do not comply with the requirements of this chapter. 701.3 Referenced codes and standards. The codes and standards referenced in this code shall be those adopted by the State of Indiana, including all codes and regulations as adopted by the Indiana Fire and Building Safety Commission, and shall collectively be referred to hereafter as the Indiana Fire Code. SECTION 702 MEANS OF EGRESS 702.1 General. A safe, continuous and unobstructed path of travel shall be provided from any point in a building or structure to the public way. Means of egress shall comply with the code under which the building was constructed. 702.2 Aisles. The required width of aisles in accordance with the code under which the building was constructed shall be unobstructed. 702.3 Locked doors. Means of egress doors shall be readily openable from the side from which egress is to be made without the need for keys, special knowledge or effort, except where the door hardware conforms to that permitted by the Indiana Fire Code. 702.4 Emergency escape and rescue openings. Required emergency escape and rescue openings shall be maintained in accordance with the code in effect at the time of construction, and both of the following: 1. Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. 2. Bars, grilles, grates or similar devices are permitted to be placed over emergency escape and rescue openings provided that the minimum net clear opening size complies with the code that was in effect at the time of construction and the unit is equipped with smoke alarms installed in accordance with the Indiana Fire Code. Such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening. SECTION 703 FIRE RESISTANCE RATINGS 703.1 Fire-resistance-rated assemblies. The provisions of this chapter shall govern maintenance of the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated construction separation of adjacent spaces to safeguard against the spread of fire and smoke within a building and the spread of fire to or from buildings. 703.2 Unsafe conditions. Where any components are not maintained and do not function as intended or do not have the fire resistance required by the code under which the building was constructed or altered, such components or portions thereof shall be deemed unsafe conditions in accordance with the Indiana Fire Code. Components or portions thereof determined to be unsafe shall be repaired or replaced to conform to that code under which the building was constructed or altered. Where the condition of components is such that any building, structure or portion thereof presents an imminent danger to the occupants of the building, structure or portion thereof, the fire code official shall act in accordance with the Indiana Fire Code. 703.3 Maintenance. The required fire-resistance rating of fire-resistance-rated construction, including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and joint systems, shall be maintained. Such elements shall be visually inspected annually by the owner and repaired, restored or replaced where damaged, altered, breached or penetrated. Records of inspections and repairs shall be maintained. Where concealed, such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel, access door, ceiling tile or entry to the space. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer and any other reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. 703.3.1 Fire blocking and draft stopping. Required fire blocking and draft stopping in combustible concealed spaces shall be maintained to provide continuity and integrity of the construction. 703.3.2 Smoke barriers and smoke partitions. Required smoke barriers and smoke partitions shall be maintained to prevent the passage of smoke. Openings protected with approved smoke barrier doors or smoke dampers shall be maintained in accordance with Indiana Fire Code. 703.3.3 Fire walls, fire barriers, and fire partitions. Required fire walls, fire barriers and fire partitions shall be maintained to prevent the passage of fire. Openings protected with approved doors or fire dampers shall be maintained in accordance with Indiana Fire Code. 703.4 Opening protectives. Opening protectives shall be maintained in an operative condition in accordance with Indiana Fire Code. The application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed, or otherwise made inoperable. Fusible links shall be replaced whenever fused or damaged. Fire door assemblies shall not be modified. 703.4.1 Signs. Where required by the code official, a sign shall be permanently displayed on or near each fire door in letters not less than 1 inch (25 mm) high to read as follows: 1. For doors designed to be kept normally open: FIRE DOOR - DO NOT BLOCK. 2. For doors designed to be kept normally closed: FIRE DOOR - KEEP CLOSED. 703.4.2 Door operation. Swinging fire doors shall close from the full-open position and latch automatically. The door closer shall exert enough force to close and latch the door from any partially open position. 703.5 Ceilings. The hanging and displaying of salable goods and other decorative materials from acoustical ceiling systems that are part of a fire-resistance-rated horizontal assembly shall be prohibited. 703.6 Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm operation and full closure. Records of inspections and testing shall be maintained. 703.7 Vertical shafts. Interior vertical shafts, including stairways, elevator hoistways and service and utility shafts, which connect two or more stories of a building shall be enclosed or protected as required in Indiana Fire Code. New floor openings in existing buildings shall comply with the International Building Code. 703.8 Opening protective closers. Where openings are required to be protected, opening protectives shall be maintained self-closing or automatic-closing by smoke detection. Existing fusible-link-type automatic door-closing devices shall be replaced if the fusible link in accordance with Indiana Fire Code. SECTION 704 FIRE PROTECTION SYSTEMS 704.1 Inspection, testing and maintenance. Fire protection and life safety systems shall be maintained in accordance with the Indiana Fire Code in an operative condition at all times, and shall be replaced or repaired where defective. 704.1.1 Fire protection and life safety systems. Fire protection and life safety systems shall be installed, repaired, operated and maintained in accordance with this code the Indiana Fire Code and the Indiana Building Code. 704.1.2 Required fire protection and life safety systems. Fire protection and life safety systems required by this code, the Indiana Fire Code or the Indiana Building Code shall be installed, repaired, operated, tested and maintained in accordance with this code. A fire protection and life safety system for which a design option, exception or reduction to the provisions of this code, the Indiana Fire Code or the Indiana Building Code has been granted shall be considered to be a required system. 704.1.3 Fire protection systems. Fire protection systems shall be inspected, maintained and tested in accordance with the Indiana Fire Code requirements. 1. Automatic sprinkler systems. 2. Automatic fire-extinguishing systems protecting commercial cooking systems 3. Automatic water mist extinguishing systems 4. Carbon dioxide extinguishing systems 5. Carbon monoxide alarms and carbon monoxide detection systems 6. Clean-agent extinguishing systems 7. Dry-chemical extinguishing systems 8. Fire alarm and fire detection systems 9. Fire department connections 10. Fire pumps 11. Foam extinguishing systems 12. Halon extinguishing systems. 13. Single- and multiple-station smoke alarms. 14. Smoke and heat vents and mechanical smoke removal systems. 15. Smoke control systems. 16. Wet-chemical extinguishing systems. 17. Duct and air transfer openings. 704.2 Standards. Fire protection systems shall be inspected, tested and maintained in accordance with the Indiana Fire Code. 704.3 Systems out of service. Where a required fire protection system is out of service, the fire department and the fire code official shall be notified immediately and, where required by the fire code official, either the building shall be evacuated or an approved fire watch shall be provided for all occupants left unprotected by the shutdown until the fire protection system has been returned to service. Where utilized, fire watches shall be provided with not less than one approved means for notification of the fire department and shall not have duties beyond performing constant patrols of the protected premises and keeping watch for fires. Actions shall be taken in accordance with Indiana Fire Code to bring the systems back in service. Exception: Facilities with an approved notification and impairment management program. The notification and impairment program for water-based fire protection systems shall comply with Indiana Fire Code. 704.3.1 Emergency impairments. Where unplanned impairments of fire protection systems occur, appropriate emergency action shall be taken to minimize potential injury and damage. The impairment coordinator shall implement the steps outlined in the Indiana Fire Code. 704.4 Removal of or tampering with equipment. It shall be unlawful for any person to remove, tamper with or otherwise disturb any fire protection or life safety system required by this code except for the purposes of extinguishing fire, training, recharging or making necessary repairs. 704.4.1 Removal of or tampering with appurtenances. Locks, gates, doors, barricades, chains, enclosures, signs, tags and seals that have been installed by or at the direction of the fire code official shall not be removed, unlocked, destroyed or tampered with in any manner. 704.4.2 Removal of existing occupant-use hose lines. The fire code official is authorized to permit the removal of existing occupant-use hose lines where all of the following apply: 1. The installation is not required by the Indiana Fire Code or the Indiana Building Code. 2. The hose line would not be utilized by trained personnel or the fire department. 3. The remaining outlets are compatible with local fire department fittings. 704.4.3 Termination of monitoring service. For fire alarm systems required to be monitored by the Indiana Fire Code, notice shall be made to the fire code official whenever alarm monitoring services are terminated. Notice shall be made in writing by the provider of the monitoring service being terminated. 704.5 Fire department connection. Where the fire department connection is not visible to approaching fire apparatus, the fire department connection shall be indicated by an approved sign mounted on the street front or on the side of the building in accordance with Indiana Fire Code. Such signs shall be subject to the approval of the fire code official. 704.5.1 Fire department connection access. Ready access to fire department connections shall be maintained at all times and without obstruction by fences, bushes, trees, walls or any other fixed or movable object. Access to fire department connections shall be approved by the fire chief. Exception: Fences, where provided with an access gate equipped with a sign complying with the legend requirements of the Indiana Fire Code and a means of emergency operation. The gate and the means of emergency operation shall be approved by the fire chief and maintained operational at all times. 704.5.2 Clear space around connections. A working space of not less than 36 inches (914 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be provided and maintained in front of and to the sides of wall-mounted fire department connections and around the circumference of freestanding fire department connections. 704.6 Single- and multiple-station smoke alarms. Single- and multiple-station smoke alarms shall be installed in existing Group 1-1 and R occupancies in accordance with Sections 704.6.1 through 704.6.3. 704.6.1 Where required. Existing Group 1-1 and R occupancies shall be provided with single-station smoke alarms in accordance with Sections 704.6.1.1 through 704.6.1.4. Interconnection and power sources shall be in accordance with Sections 704.6.2 and 704.6.3. Exceptions: 1. Where the code that was in effect at the time of construction required smoke alarms and smoke alarms complying with those requirements are already provided. 2. Where smoke alarms have been installed in occupancies and dwellings that were not required to have them at the time of construction, additional smoke alarms shall not be required provided that the existing smoke alarms comply with requirements that were in effect at the time of installation. 3. Where smoke detectors connected to a fire alarm system have been installed as a substitute for smoke alarms. 704.6.1.1 Group R-1. Single- or multiple-station smoke alarms shall be installed in all of the following locations in Group R-1: 1. In sleeping areas. 2. In every room in the path of the means of egress from the sleeping area to the door leading from the sleeping unit. 3. In each story within the sleeping unit, including basements. For sleeping units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. 704.6.1.2 Groups R-2, R-3, R-4 and 1-1. Single or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of occupant load at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. 704.6.1.3 Installation near cooking appliances. Smoke alarms shall AGt—be installed a minimum of 10 feet (3.0 m) horizontally from a permanently installed cooking appliance. Exception: Smoke alarms shall be permitted to be installed a minimum of 6 feet (1.8 m) horizontally from a permanently installed cooking appliance where necessary to comply with Section 704.6.1.1 or 704.6.1.2. 704.6.1.4 Installation near bathrooms. Smoke alarms shall be installed not less than 3 feet (914 mm) horizontally from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a smoke alarm required by Section 704.6.1.1 or 704.6.1.2. 704.6.2 Interconnection. Where more than one smoke alarm is required to be installed within an individual dwelling or sleeping unit, the smoke alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms in the individual unit. Physical interconnection of smoke alarms shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. Exceptions: 1. Interconnection is not required in buildings that are not undergoing alterations, repairs or construction of any kind. 2. Smoke alarms in existing areas are not required to be interconnected where alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available that could provide access for interconnection without the removal of interior finishes. 704.6.3 Power source. Single-station smoke alarms shall receive their primary power from the building wiring provided that such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms with integral strobes that are not equipped with battery backup shall be connected to an emergency electrical system. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection. Exceptions: 1. Smoke alarms are permitted to be solely battery operated in existing buildings where construction is not taking place. 2. Smoke alarms are permitted to be solely battery operated in buildings that are not served from a commercial power source. 3. Smoke alarms are permitted to be solely battery operated in existing areas of buildings undergoing alterations or repairs that do not result in the removal of interior walls or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available that could provide access for building wiring without the removal of interior finishes. 704.6.4 Smoke detection system. Smoke detectors listed in accordance with UL 268 and provided as part of the building's fire alarm system shall be an acceptable alternative to single- and multiple-station smoke alarms and shall comply with the following: 1. The fire alarm system shall comply with all applicable requirements in the Indiana Fire Code. 2. Activation of a smoke detector in a dwelling or sleeping unit shall initiate alarm notification in the dwelling or sleeping unit in accordance with the Indiana Fire Code. 3. Activation of a smoke detector in a dwelling or sleeping unit shall not activate alarm notification appliances outside of the dwelling or sleeping unit, provided that a supervisory signal is generated and monitored in accordance with the Indiana Fire Code. 704.7 Single- and multiple-station smoke alarms. Single- and multiple-station smoke alarms shall be tested and maintained in accordance with the manufacturer's instructions and this code. 704.7.1 Replacement. Smoke alarms shall be replaced where any of the following apply: 1. The smoke alarm fails to respond to operability tests. 2. Where the smoke alarm exceeds 10 years from the date of manufacture marked on the unit, unless an earlier replacement is specified in the manufacturer's instructions. 3. The smoke alarm end-of-life signal is sounded. 4. The smoke alarm date of manufacturer cannot be determined. SECTION 705 CARBON MONOXIDE ALARMS AND DETECTION 705.1 General. Carbon monoxide alarms shall be installed in dwellings within or near each separate sleeping area and on each level of a dwelling. 705.2 Carbon monoxide alarms and detectors. Carbon monoxide alarms and carbon monoxide detection systems shall be maintained and tested annually. Carbon monoxide alarms and carbon monoxide detectors that become inoperable or begin producing end-of-life signals shall be replaced.

(Ord. No. 2025-50, § 2(Exh. A), 11-3-25)

Ask a question about Lafayette law

Corpus searches the Lafayette sections it holds and shows the ones that match, with their citations. Free, no sign-in.