§ 4.13.080 — Constructional requirements
Municipal Code of the City of Lafayette, Indiana (Codified through Ordinance of May 20, 2026. (Supp. No. 61, 11-26)) · Lafayette Municipal Code § 4.13.080
Corpus is an independent public-information project, not the official City of Lafayette website. Stable reference: corpuslaw.us/code/81dd21e1-e089-4d01-a419-1c83183b6c0f
4.13.080 - Constructional requirements.
The following requirements are illustrative. Other construction is acceptable when evidence is presented by actual firing on equivalent test samples using the heaviest ammunition that might be employed on the range. A. Wall Construction. 1. Walls in the critical zone may be standard grade concrete blocks with their cavities filled with crushed rock of three-fourths of an inch or smaller screen. Sand is not acceptable. Concrete of any density is acceptable as the fill. Other suitable constructions are: four inches of reinforced concrete, one fourth of an inch of mild steel over an appropriate supporting surface, single layer of face brick. 2. Walls in the secondary zone may be standard grade concrete blocks without filled cavities. Other suitable constructions are: three inches of reinforced concrete, one eighth of an inch of mild steel over an appropriate supporting surface. Wood planking, plywood, and gypsum board may be used in sufficient thicknesses to be ballistically equivalent, but may result in excessive maintenance. 3. Wall baffles may be used in lieu of the above constructions for either zone. When used there is no ballistical security requirement for the walls. The baffles are vertical steel members, angled out from the side walls. When used the following requirements must be met: a. The baffles must shelter the wall so that misdirected shots from all shooting points are interrupted by the baffles before striking the wall. b. The baffles must be so angled that no bullet may hit any baffle at a greater angle than forty-five (45) degrees. c. The baffle steel must be of sufficient thickness that it is not dented by the heaviest ammunition if left bare. Or if covered with a wood surface it must be of sufficient thickness that, even if dented, its structural integrity is maintained. (Note: see subsection F of this section for wood facings.) B. Floor Construction. 1. In the critical zone, floors shall be reinforced concrete of four-inch minimum thickness. The minimum thickness for the other floors is determined by the structural needs of the building and exceeds that required for ballistical security. 2. In new construction the floor shall be graded to a downrange floor drain. C. Ceiling and Roof Construction. Two cases are encountered. Least common is the slab roof or ceiling. In most cases the need to protect beams, lights, conduits, ducts and the like, require a series of protective guards. In some cases both may be used on the same range. 1. Exposed slab ceiling or roof must be governed by the same requirements as floors. If the bottom surface of the slab is not smooth the following shall govern. 2. Ceiling baffles must be provided to protect any item that may interrupt the downrange travel of bullets from an angle of forty-five (45) degrees to the vertical ahead of the shooter to the bullet trap. a. If the ceiling baffles protect the entire overhead area, each baffle starting its protection where the previous one left off, then there is no ballistical security requirement for the ceiling or roof above. b. The baffle construction must otherwise comply with the requirements for wall baffles. D. Protuberances. Columns, pilasters, exposed piping, and other protuberances downrange shall be protected from damage and prevented from causing ricochets. 1. Angled steel plates may be used for all protuberances. The requirements for wall baffles shall govern. 2. Pilasters may be faired to the wall with concrete so that the angle to the wall of the surface of the fairing concrete is thirty (30) degrees or less. E. Plumbing (for flushing out the unburned gunpowder). 1. In new construction, there shall be a floor drain downrange and a hose bib in the range area. 2. In existing construction, the floor drain may be waived if a slop sink is located within fifty (50) feet of the range. F. Wood Facings. Wood facings are not allowed for protection of surfaces unless they are separated from any hard surface (steel or masonry) behind them by an air space of at least one inch.
(Ord. 83-3, 4-4-83) Penalty, see § 1.01.990
Ask a question about Lafayette law
Corpus searches the Lafayette sections it holds and shows the ones that match, with their citations. Free, no sign-in.