§ 8.08.310 — Policy on stormwater quantity management
Municipal Code of the City of Lafayette, Indiana (Codified through Ordinance of May 20, 2026. (Supp. No. 61, 11-26)) · Lafayette Municipal Code § 8.08.310
Corpus is an independent public-information project, not the official City of Lafayette website. Stable reference: corpuslaw.us/code/8f00ecc4-3b68-4ad0-8699-b75636b38970
8.08.310 - Policy on stormwater quantity management.
A. Detention Policy. It is recognized that most streams and drainage channels serving City of Lafayette do not have sufficient capacity to receive and convey stormwater runoff resulting from continued urbanization. Accordingly, except for situations provided in subsections (A)(3) and (4) of this section, the storage and controlled release of excess stormwater runoff shall be required for all developments and redevelopments located within City of Lafayette. 1. General Release Rates. In general, the post-developed release rates from development sites shall be no greater than the general release rates provided in Table 3-1. For sites where the pre-developed area has more than one outlet, the release rates should be computed based on pre-developed discharge to each outlet point. TABLE 3-1 General Release Rates (cfs/acre) Based on Pre-Developed Condition Curve Number at Each Outlet Point Curve Number | 10-Year | 100-Year < 65 | 0.07 | 0.23 66—69 | 0.13 | 0.33 70—73 | 0.20 | 0.43 74—77 | 0.27 | 0.53 78—81 | 0.34 | 0.63 82—85 | 0.44 | 0.75 > 86 | 0.55 | 0.87 For sites where depressional storage exists, the general release rates provided above may have to be further reduced. If depressional storage exists at the site, site-specific release rates must be calculated according to methodologies described in the Stormwater Technical Standards Manual (Technical Standards), accounting for the depressional storage by modeling it as a pond whose outlet is a weir at an elevation that stormwater can currently overflow the depressional storage area. Post developed release rates for sites with depressional storage shall be the two-year pre-developed peak runoff rate for the post-developed ten (10) year storm and the ten (10) year pre-developed peak runoff rate for the post-developed one hundred (100) year storm. In no case shall the calculated site-specific release rates be larger than the general rates provided above. Also, note that for determining the post-developed peak runoff rates, the depressional storage must be assumed to be filled unless the City of Lafayette can be assured that the noted storage will be preserved in perpetuity. Runoff from all upstream tributary areas (off-site land areas) may be bypassed around the detention/retention facility without attenuation. Such runoff may also be routed through the detention/retention facility, provided that a separate outlet system or channel is incorporated for the safe passage of such flows, i.e., not through the primary outlet of a detention facility. Unless the pond is being designed as a regional detention facility, the primary outlet structure shall be sized, and the invert elevation of the emergency overflow weir determined according to the on-site runoff only. Once the size and location of the primary outlet structure as well as the invert elevation of the emergency overflow weir is determined by considering on-site runoff, the one hundred (100) year pond elevation is determined by routing the entire inflow, on-site and off-site, through the pond. Note that the efficiency of the detention/retention facility in controlling the on-site runoff may be severely affected if the off-site area is considerably larger than the on-site area. As a general guidance, on-line detention may not be effective in controlling on-site runoff where the ratio of off-site area to on-site area is larger than 5:1. Additional detention (above and beyond that required for on-site area) may be required by the City of Lafayette when the ratio of off-site area to on-site area is larger than 5:1. 2. Downstream Restrictions. In the event the downstream receiving channel or storm sewer system is inadequate to accommodate the post-developed release rate provided above, then the allowable release rate shall be reduced to that rate permitted by the capacity of the receiving downstream channel or storm sewer system. Additional detention, as determined by the City of Lafayette, shall be required to store that portion of the runoff exceeding the capacity of the receiving sewers or waterways. If the proposed development makes up only a portion of the undeveloped watershed upstream of the limiting restriction, the allowable release rate for the development shall be in direct proportion to the ratio of its drainage area to the drainage area of the entire watershed upstream of the restriction. In accordance with Section 8.08.670, the allowable release rates may be further reduced by the City of Lafayette if on-site or off-site conditions warrant the reduction. Notwithstanding the foregoing, if the City of Lafayette determines within three years after final approval of the stormwater plans that the downstream receiving channel or storm sewer system are in fact inadequate to accommodate the as-built development and have been damaged thereby, or if the subject as-built system is inadequate to accommodate upstream runoff or has caused damage to the upstream channel or storm sewer system, the owner, developer, or contractor shall be required to take such corrective actions as the City of Lafayette shall determine to be reasonably necessary to remedy such damages and enable such channels and storm sewers to accommodate the as-built drainage system. 3. Exemptions for Detention Requirements. Detention will not be required for the following: a. Land alterations where the primary basis on which a stormwater drainage permit is required is the construction, enlargement, or location (on a permanent foundation) of a one-family dwelling, two-family dwelling, or accessory structure appurtenant to either a one- or two-family dwelling. b. Approved fill areas or one-time addition to existing commercial buildings that do not increase the amount of impervious area on-site by more than a total of 0.5 acres, provided the existing runoff patterns and flow capacity of the property will not be altered by the filling operations. c. Notwithstanding the provisions of subsection (A)(2) (above), those site developments where the stormwater management system has been designed such that: i. After combining flows from both the off-site and on-site drainage areas, there will be no increase in the total peak discharge from the developing site during the two, ten (10), or one hundred (100) year storm events (assuming the pre-developed land use used in the analysis is based on conditions that existed from historic aerial photographs, at least 50% of the time over the last 30 years); ii. The volume of runoff for each project site outlet has not been increased for the entire range of storm events, up to the one hundred (100) year storm event; and iii. The flow width is greater than or equal to that flow width which existed prior to the development (for the entire range of storm event, up to the one hundred (100) year storm event) and the velocity at the property boundary line for each sub-basin is less than or equal to that velocity which existed prior to the development (for the entire range of storm events, up to the one hundred (100) year storm event); and iv. The drainage report for the proposed development includes a section that clearly indicates the upper limit of imperviousness to which the development can build and still meet the detention exemption. d. Where the direct release of runoff from the proposed development meets the conditions set forth in subsection (A)(4) (below). 4. Direct Release Provisions. It is the policy of the City of Lafayette to allow the direct release (no detention) of runoff from a proposed development to an adjacent stream with more than one hundred (100) square miles of contributing drainage area at the direct release point. Therefore, direct release may be allowed for parcels adjacent to the following stream reaches in the City of Lafayette: a. Wabash River — the entire reach within the county; b. Tippecanoe River — the entire reach within the county; c. Wildcat Creek — the entire reach within the county; d. South Fork Wildcat Creek — the entire reach within the county; e. Middle Fork Wildcat Creek — the entire reach within the county; f. Wea Creek — downstream of Dismal Ditch (a.k.a. Kenny Ditch). Due to unknowns regarding the future development patterns and the associated proposed stormwater management systems within a watershed, it is the policy of the City of Lafayette to discourage direct release to a stream with less than one hundred (100) square miles of contributing drainage area at the direct release point. However, in rare circumstances, where a comprehensive watershed-wide hydrologic study or watershed plan of a major stream adopted by the City of Lafayette substantiates the benefits of (or allows for) direct release for a proposed development located adjacent to a major stream, the detention requirements set in subsection (A)(1) (above) may be waived. In substantiating the potential benefits of direct release, the watershed-wide hydrologic study provided by the applicant must demonstrate that the peak discharge associated with two-year, ten (10) year, and one hundred (100) year precipitation events would not increase along the receiving stream. At a minimum, the stream reach to be examined needs to extend from the direct release point to a point downstream with a drainage area at least ten (10) times the drainage area of the proposed development and its off-site contributing drainage area. The required analyses must be done both for the existing land use and future potential land use (developed conditions) in the watersheds involved. To be applicable to the development site, the sub-basin sizes for the watershed-wide hydrologic analyses of the major stream (including the sub-basin area containing the proposed development and its off-site contributing areas) must be generally uniform (between 0.5 and 2.0 times the average sub-basin size). Furthermore, the maximum size of the sub-basin area containing the proposed development and its off-site contributing areas should not exceed five times the area of the proposed development. B. Grading and Building Pad Elevation Policy. In addition to all floodplain requirements noted in the Unified Zoning Ordinance, FPG applicable to all buildings located within SFHA or an IDNR designated best available data floodplain or regulated adjacent areas (if applicable and if such buildings are allowed under the Unified Zoning Ordinance) shall be shown on the final plat. For all structures located outside of SFHA or an IDNR designated one hundred (100) year floodplain that are subject to flooding from a stream or an open ditch (an area along a stream with no floodplain designation or an area adjacent to a designated floodplain with ground elevation below one hundred (100) year flood elevation plus two feet), the LAG of all residential, commercial, or industrial buildings shall have a minimum of two feet of freeboard above the one hundred (100) year flood elevation. For all structures fronting a flooding source other than a swale or an emergency flood route, the floor of any basements or crawl spaces (if provided) shall be a minimum of one foot above the normal pool level (if pond) or the two-year flood level (if a stream or an open ditch). In addition, special considerations, based on detailed geotechnical analysis, should be made prior to considering placement of any basement below the one hundred (100) year flood elevation of an adjacent flooding source or pond. For all structures located outside FEMA or IDNR designated floodplains that are subject to flooding from a detention/retention pond, the lowest adjacent grade (LAG) of all residential, commercial, or industrial buildings shall have a minimum of two feet of freeboard above the one hundred (100) year flood elevation or the emergency overflow weir elevation, whichever is higher. For all structures, the building's lowest entry elevation shall be constructed such that drainage is not directed against the building and shall be in accordance with applicable local building codes. There shall be a positive slope drainage away from the building with maximum yard slopes that are 3:1 where soil has been disturbed during construction processes. Overflow paths throughout the development resulting from a one hundred (100) year storm event, shall be determined, clearly shown on the plans, and contained in permanent drainage easements along the centerline of the flow path. No fences or landscaping shall be constructed within the easement areas that may impede the free flow of stormwater. For all structures adjacent to an overflow path, the minimum adjacent grade of the portion of the structure (the ground elevation next to the building after construction is completed that sits adjacent to the overflow path or may be subject to flooding by the overflow path) shall be a minimum of one foot above the estimated one hundred (100) year elevation of the overflow path using methodologies described in the Technical Standards. In addition to the policies described above, potential flooding that would impact the site due to the minimum overtopping elevation of adjacent roads shall be considered. It shall be the property owners' responsibility to maintain the natural features on their lots and to take preventive measures against any and all erosion and/or deterioration of natural or manmade features on their lots. C. Adjoining Property Impacts Policy. Design and construction of the stormwater facility shall provide for the discharge of the stormwater runoff from off-site land areas as well as the stormwater from the area being developed (on-site land areas) to an acceptable outlet(s) (as determined by the City Engineer) having capacity to receive upstream (off-site) and on-site drainage. The flow path from the development outfall(s) to a regulated drain or natural waterway (as determined by the City Engineer) shall be provided on an exhibit that includes topographic information. Any existing field tile encountered during the construction shall also be incorporated into the proposed stormwater drainage system or tied to an acceptable outlet. In addition, no activities conducted as part of the development shall be allowed to obstruct the free flow of flood waters from an upstream property. Where the outfall from a stormwater drainage system of any developer flows through real estate not owned by the developer prior to reaching a regulated drain or natural waterway (as determined by the City Engineer), no approval shall be granted for the Stormwater Drainage System until all owners of real estate and/or tenants thereof crossed by the outfall either consent in writing to the use of their real estate or are notified in writing of a hearing before the Board of Public Works and Safety with respect to the proposed use. Written notice of the time and place of the hearing shall be made by: (1) mailing a copy of the notice by registered or certified mail, return receipt requested to such person's residence, place of business or employment with return receipt requested and returned showing receipt of such notice; or (2) delivering a copy of such notice to the owner and/or such tenant personally. Such notice shall be personally delivered or mailed not less that seven nor more than fourteen (14) days prior to the hearing. Proof of delivery of notice to each landowner shall be filed by affidavit with the Board of Public Works and Safety prior to the hearing. If an adequate outlet is not located on site, then off-site drainage improvements may be required. Those improvements may include but are not limited to: extending storm sewers, clearing, dredging and/or removal of obstructions to open drains or natural water courses, and the removal or replacement of undersized culvert pipes as required by the City Engineer. If, during design of a development, downstream landowners request access to a storm sewer that is proposed to be extended through their property prior to reaching a regulated drain or natural waterway (so that the downstream landowner can outlet agricultural field tiles), the construction plans must indicate that only proposed and/or future pattern field tile access points, and details of the proposed and/or future connections to the off-site storm sewer. The drainage report must include calculations to show that the off-site storm sewer has been increased in size to accommodate the proposed and/or future additional flow. D. No Net Loss Floodplain Storage Policy. Floodplains exist adjacent to all natural and man-made streams, regardless of contributing drainage area or whether they have been previously identified or mapped. Due to potential impacts of floodplain loss on peak flows in streams and on the environment, floodplains are considered Impact Drainage Areas and disturbance to these areas should be avoided. When the avoidance of floodplain disturbance is not practical, the natural functions of the floodplain should be preserved to the extent possible. In an attempt to strike a balance between the legitimate need for economic development within the City of Lafayette and the ever-increasing importance of and the need to preserve the natural functions of floodplains to the extent possible (especially given ongoing and projected climate change impacts), compensatory excavation equivalent to the floodplain storage lost shall be required for all activities within the area inundated by the one hundred (100) year flood elevation along the floodplain of streams located in the City of Lafayette where drainage area of the stream is equal to or larger than one square mile. The City Engineer may alter the compensation ratio, based on extenuating circumstances, for a specific project. Detailed requirements regarding the location and methods of calculations are provided in the Technical Standards.
(Ord. 2008-03 § 2 (part), 2-4-08; Ord. No. 2011-27, §§ 3, 4, 12-5-11; Ord. No. 2023-06, § 7, 3-6-23)
Ask a question about Lafayette law
Corpus searches the Lafayette sections it holds and shows the ones that match, with their citations. Free, no sign-in.