For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8.08.510 — Policy on stormwater quality management

Municipal Code of the City of Lafayette, Indiana (Codified through Ordinance of May 20, 2026. (Supp. No. 61, 11-26)) · Lafayette Municipal Code § 8.08.510

Corpus is an independent public-information project, not the official City of Lafayette website. Stable reference: corpuslaw.us/code/191dd736-6553-445f-ae2e-1c5712d52e07

8.08.510 - Policy on stormwater quality management.

It is recognized that developed areas, as compared to undeveloped areas, generally have increased imperviousness, decreased infiltration rates, increased runoff rates, and increased concentrations of pollutants such as fertilizers, herbicides, greases, oil, salts and other pollutants. As new development and re-development continues in the City of Lafayette measures must be taken to intercept and filter pollutants from stormwater runoff prior to reaching regional creeks, streams, and rivers in order to preserve fishable and swimmable conditions. Through the use of best management practices (BMP), stormwater runoff will be filtered and harmful amounts of sediment, nutrients and contaminants will be removed. The project site owner must submit to the City of Lafayette, a Storm Water Pollution Prevention Plan (SWPPP) which shows placement of appropriate BMP(s) from a pre-approved list of BMPs specified in the Indiana Stormwater Quality Manual or the Technical Standards. The noted BMPs must be designed, constructed, and maintained according to guidelines provided or referenced in the Indiana Stormwater Quality Manual or the Technical Standards. Practices other than those specified in the pre-approved list may be utilized. However, the burden of proof, as to whether the performance and ease of maintenance of such practices will be according to guidelines provided in the Indiana Stormwater Quality Manual or the Technical Standards, shall be placed with the applicant. Details regarding the procedures and criteria for consideration of approval of such BMPs are provided in the Technical Standards. It is also recognized that another major source of pollution in many Indiana streams, including those within the corporate boundaries of the city, is the streambank erosion associated with urbanizing watersheds. Stream channels develop their shape in response to the volume and rate of runoff that they received from their contributing watersheds. Research has shown that in hydrologically stable watersheds the stream flow responsible for most of the shaping of the channel (called the bankfull flow) occurs between every one to two years. When land is developed, the volume and rate of runoff from that land increases for these comparatively small flooding events that are not normally addressed by the detention practices and the stream channel will adapt by changing its shape. As the stream channel works to reach a new stable shape, excess erosion occurs. As new development and re-development continue within the city, measures must be taken to minimize the impact of such development or re-development on streambank erosion. Through the use of appropriate best management practices (BMP's), the volume and rate of runoff for channel forming flows will be reduced in an attempt to minimize increased streambank erosion in the receiving streams and channels. Requirements of this chapter and the Technical Standards with regard to post-construction stormwater quality management can be satisfied through a variety of methods broadly categorized under two general approaches: A. Conventional approach; B. Low impact development (LID) approach. The site developer and designer are encouraged to review the LID discussion in the Technical Standards prior to site design. Gasoline outlets and refueling areas must install appropriate practices (as noted under "Hot Spots" provision in the Technical Standards) to reduce lead, copper, zinc, and polyaromatic hydrocarbons in stormwater runoff. These requirements will apply to all new facilities and existing facilities that replace their tanks, regardless of the size of the facility.

(Ord. 2008-03 § 2 (part), 2-4-08; Ord. No. 2011-27, § 10, 12-5-11; Ord. No. 2023-06, § 12, 3-6-23)

Ask a question about Lafayette law

Corpus searches the Lafayette sections it holds and shows the ones that match, with their citations. Free, no sign-in.