§ 06.04 — Building Dimensional Requirements
Code of the City of Michigan City, Indiana (Codified through Ordinance No. 4808, adopted August 5, 2026. (Supp. No. 22, Update 1)) · Michigan City Code, App. C, art. 06, § 06.04
Corpus is an independent public-information project, not the official City of Michigan City website. Stable reference: corpuslaw.us/code/cc5a921b-552d-4313-8340-0009ecd8398e
Section 06.04 - Building Dimensional Requirements
All structures shall be subject to the dimensional regulations of the following table. Table 06.04 Building Dimensional Requirements (a) District | Max. building height (b) | Min. setbacks (ft.) (c, d, e, f, g) | % Lot coverage (l) | Min. floor area per unit (sq. ft.) Height (ft.) | Height (st.) | Front yard | Side yard | Total both sides | Rear yard | Waterway (h, i) | Building | Imper. surface R4 Manufactured housing park district Perimeter setbacks for overall development | — | — | 25 (j) | 25 (k) | 50 (k) | 25 (k) | 75 | — | — | — Individual manufactured home sites | 25 | 2 | 20 | 5 | 15 | 20 | 75 | 45% | 55% | 800 [image omitted; see the official code] (a) Accessory Structures. Accessory structures shall be regulated under the requirements of Article 16. (b) Height Exceptions. No structure shall exceed the maximum height of the district except for the allowable exceptions to the height limits contained in Section 15.02. (c) Projections into Yards. All required yard spaces shall remain as landscaped open space, except for accessory structures and architectural features that are allowed to extend or project into required setbacks under Section 15.01. (d) Setback from Road. The front yard setback shall be measured from the road right-of-way or private road easement. (e) Corner Lots. Corner lots shall provide the minimum front yard setback from both road frontages. (f) Double Frontage Lots. In all districts, where a double frontage lot backs-up to a roadway, the minimum required front or roadside setback shall be required from both road rights-of-way. (g) Driveway Access. Individual manufactured home sites within a manufactured home park shall only have access from an internal road within the park. Individual units shall not have direct driveway access to a major thoroughfare. (h) Wetlands. A minimum setback of 50 feet shall be maintained from all wetlands. The setback may be adjusted according to requirements of natural resource preservation guidelines contained [in] Article 22. (i) Waterway Setback. The waterway setback shall be measured from the shoreline of the lake, river or stream. In no instance shall any structures other than docks, seawalls, retaining walls, sidewalks, boardwalks, and patios be permitted within the minimum waterway setback. The setback may be adjusted according to requirements of Natural Resource Preservation Guidelines. (j) Frontage Greenbelt. Manufactured housing parks shall be required to provide a 25-foot wide greenbelt along all public road frontages in accordance with Section 17.02(b). (k) Side and Rear Buffer Zones. Manufactured housing parks shall be required to provide landscape buffer zones around the exterior of the manufactured home park in accordance with Section 17.02(c). (l) Maximum Lot Coverage. The maximum lot coverage for buildings and impermeable surface shall be measured as follows: (1) The building coverage shall be calculated as the ratio of the footprint of all buildings, including the principal building, garages and detached accessory buildings, to the net area of the lot. (2) The total impermeable surface coverage shall be calculated as the ratio of the ground area covered by all buildings, accessory structures, decks, pools, pavement, parking, loading and storage areas, normal pool of wet detention basins to the net lot area.
Ask a question about Michigan City law
Corpus searches the Michigan City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
