For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 07.04 — Building Dimensional Requirements

Code of the City of Michigan City, Indiana (Codified through Ordinance No. 4808, adopted August 5, 2026. (Supp. No. 22, Update 1)) · Michigan City Code, App. C, art. 07, § 07.04

Corpus is an independent public-information project, not the official City of Michigan City website. Stable reference: corpuslaw.us/code/df0b8867-7abb-4802-be31-d03d45fc61d2

Section 07.04 - Building Dimensional Requirements

All structures shall be subject to the dimensional regulations of the following table. Table 07.04 Building Dimensional Requirements (a) District | Max. building height (b) | Min. setbacks (ft.) (c, d, e, f, g, h, i, j) | % Lot coverage (m) Height (ft.) | Height (st.) | Front yard | Side yard | Rear yard | Water- way (k, l) | Building | Imper. surface B1 - Neighborhood Commercial 1, 2 | 30/40 3 | 2 | 0 | 0/7 | 15 | 75 | 75% | 85% B2 - General Commercial | 40 | 3 | 25 | 0/7 | 25 | 75 | 65% | 85% B3 - Highway Commercial | 60 | 5 | 40 | 15 | 10 | 75 | 65% | 85% O1 - Office Service | 60 | 5 | 30 | 7 | 25 | 75 | 65% | 85% Table Notes: 1 See above standards for B1 Neighborhood Commercial, Adjoining R1E, Waterfront Residential. 2 B1 parcels adjoining the R1E district that are developed as of January 1, 2019 with a lot coverage greater than that allowed in this table are conforming provided there is adequate off-street or off-site parking. 3 A three-story building may be permitted by special exception when adjoining the R1E district. 4 The minimum required side yard setback is seven feet, which may be reduced to zero feet when the side lot line adjoins another lot that is zoned B1 or B2 and the side wall of the building is a fire-rated and without windows. [image omitted; see the official code] [image omitted; see the official code] (a) Accessory Structures. Accessory structures shall be regulated under the requirements of Article 16. (b) Height Exceptions. No structure shall exceed the maximum height of the district except for the allowable exceptions to the height limits contained in Section 15.02. (c) Projections into Yards. All required yard spaces shall remain as landscaped open space, except for pavement, accessory structures and architectural features that are allowed to extend or project into required setbacks under Section 15.01. (d) Yards Maintained as Landscaped Open Space. Setback areas shall be provided with landscape greenbelts and buffer zones as required in Section 17.02. (e) Outdoor Storage. Outdoor storage shall be screened in accordance with Sections 17.02 and 17.03. Storage areas shall meet the applicable building setback requirements from each lot line. (f) Setback from Road. The front yard setback shall be measured from the road right-of-way or private road easement. Detention/retention ponds shall be prohibited in the required front yard setback, unless there is no reasonable alternative due to existing topography and natural drainage problems. This restriction shall not apply to rain gardens, bio-retention swales, irrigation trench planters and other similar stormwater management alternatives to retention or detention ponds. (g) Corner Lots. Corner lots shall provide the minimum front yard setback from both road frontages. (h) Double Frontage Lots. In all districts, where a double frontage lot backs-up to a roadway, the minimum required front or roadside setback shall be required from both road rights-of-way. (i) Parking Setback. All parking, loading, and vehicular circulation aisles shall provide sufficient setback to meet the frontage greenbelt and buffer zones required by Section 17.02. (j) Loading Areas. All loading and unloading shall be provided off-street in the rear yard or interior side yard, and shall in no instance be permitted in a front yard. Where an alley exists or is provided at the rear of buildings, the rear building setback and loading requirements may be computed from the center of the alley. Loading and unloading areas located in a side yard shall be fully screened from view from a public street. No overhead doors shall be permitted in the front elevation of the building. All residential districts and uses must be screened from truck loading and unloading activities in accordance with Section 17.03. (k) Wetlands. A minimum setback of 50 feet shall be maintained from all wetlands. The setback may be adjusted according to requirements of natural resource preservation guidelines contained [in] Article 22. (l) Waterway Setback. The waterway setback shall be measured from the shoreline of the lake, river or stream. In no instance shall any structures other than docks, seawalls, retaining walls, sidewalks, boardwalks, and patios be permitted within the minimum waterway setback. The setback may be adjusted according to requirements of Natural Resource Preservation Guidelines. (m) Maximum Lot Coverage. The maximum lot coverage for buildings and impermeable surface shall be measured as follows: (1) The building coverage shall be calculated as the ratio of the footprint of all buildings, including the principal building, garages and detached accessory buildings, to the net area of the lot. (2) The total impermeable surface coverage shall be calculated as the ratio of the ground area covered by all buildings, accessory structures, decks, pools, pavement, parking, loading and storage areas, normal pool area of wet detention basins to the net lot area. (n) Building Side Yard Setback. The minimum side yard setback in B1 and B2 shall be zero where the side lot line adjoins another lot that is zoned as a business district and the side wall is a fire rated wall with no windows. Where a lot borders on a residential district, there shall be provided a minimum 20-foot setback on the side bordering the residential district.

(Ord. No. 4500, § 5.10., 2-5-2019)

Ask a question about Michigan City law

Corpus searches the Michigan City sections it holds and shows the ones that match, with their citations. Free, no sign-in.