§ 13.05 — Building Design Requirements
Code of the City of Michigan City, Indiana (Codified through Ordinance No. 4808, adopted August 5, 2026. (Supp. No. 22, Update 1)) · Michigan City Code, App. C, art. 13, § 13.05
Corpus is an independent public-information project, not the official City of Michigan City website. Stable reference: corpuslaw.us/code/61c600b0-1b11-4a94-96df-0008c6e3a9f2
Section 13.05 - Building Design Requirements
This section outlines the building type specifications for the overlay district. (a) General and Mixed-Use Buildings. All commercial buildings and mixed-use buildings that contain non-residential and residential uses, such as retail on the ground floor, and residential on upper floors and live-work units, shall meet the following requirements. General and Mixed-Use Buildings Front Facade | The front facade that faces a street or plaza shall include windows, cornice work, edge detailing and decorative finish materials. | [image omitted; see the official code] Ground Floor Windows and Doors | Between 2 and 10 feet above the sidewalk, at least 50% of the ground floor facade area facing a street shall be clear windows and doorways. Required window areas shall allow views into retail space, working areas or lobbies, pedestrian entrances or display windows set into the wall. Windows may not be covered or blocked with the back of shelving units. Upper Floor Windows | Openings above the first story shall be vertical in proportion. Entrance | There shall be a minimum of one (1) usable pedestrian entrance along the front public sidewalk. Main pedestrian entrances shall have design details that enhance the appearance and prominence of the entrance so that it is recognizable from the street and parking areas. Blank Walls | Blank walls (without windows) longer than 20 feet shall not face a street. Garage Doors | Garage doors shall not be permitted on a front facade; except opening/doors for access to structured parking or rear yard parking are permitted. Flat Roof Buildings | Buildings with a flat roof appearance from the street shall have a decorative cornice. Flat roofs shall be enclosed by parapets. Pitched Roof Buildings | Buildings with a pitched roof shall be permitted where the eaves are at least 20 feet from the ground and the roof pitch is a minimum of 4:12. Mechanical Equipment Screening | All rooftop HVAC mechanical mounted equipment shall be screened from view on all sides of the building. Parapets and other screening treatment shall use high quality building materials and shall blend with the design of the building in terms of color and materials. (b) Franklin Boulevard Storefront Building. All buildings fronting on Franklin Boulevard, except civic buildings, shall meet the following requirements for the facade facing Franklin Boulevard. This building type shall be occupied by commercial uses or mixed-uses (which contain non-residential and residential uses, such as retail on the ground floor and residential on upper floors). Franklin Storefront Buildings Ground Floor Storefront | Ground floors shall be designed with storefronts that have windows, doorways and signage, which are integrally designed and painted. Storefront buildings shall be designed to create a distinct and separated ground floor area through the use of accent such as a string course, change in material or textures, or an awning or canopy between the first and second stories. | [image omitted; see the official code] Ground Floor Windows and Doors | Between 2 and 10 feet above the sidewalk, at least 70% of the storefront/ground floor facade facing the street shall be clear windows and doorways. Glass areas on storefronts shall be clear or lightly tinted. Mirrored glass is prohibited. Required window areas shall allow views into retail space, working areas, lobbies, pedestrian entrances or display windows. Windows shall not be blocked with opaque materials or the back of shelving units. Upper Floor Windows | Openings above the first story shall be a maximum of 50% of the total facade area. Windows above the first story shall be vertical in proportion. Entrance | There shall be a minimum of one (1) usable pedestrian entrance every full 50 feet of frontage along the front public sidewalk. Main pedestrian entrances shall have design details that enhance the appearance and prominence of the entrance so that it is recognizable from the street and parking areas. Blank Walls | Blank walls (without windows) longer than 20 feet shall not face a street and building walls shall be articulated with wall projections/recessions, variable materials, colors or details to visually break-up the wall. Garage Doors | Garage doors shall not be permitted on a front facade; however, openings for parking structure entrances and drives leading to loading areas are permitted. Secondary Facade | For a building located on a corner lot, the second front facade facing the lesser traveled street may have the above door and window requirement of the first floor reduced to 1/2 the required amount of fenestration, provided the secondary facade is not facing Franklin Boulevard. Flat Roof Buildings | Buildings with a flat roof appearance from the street shall have a decorative cornice. Flat roofs shall be enclosed by parapets. Pitched Roof Buildings | Buildings with a pitched roof shall be permitted where the eaves are at least 20 feet from the ground and the roof pitch is a minimum of 4:12. Mechanical Equipment Screening | All rooftop HVAC mechanical mounted equipment shall be screened from view on all sides of the building. Parapets and other screening treatment shall use high quality building materials and shall blend with the design of the building in terms of color and materials. (c) Cottage Shop Building. Buildings that were originally constructed as residences and converted to a non-residential use or constructed to appear as residential conversions shall meet the following requirements. Cottage Shop Building Front Facade | There shall be a minimum of one (1) usable pedestrian entrance along the front public sidewalk. | [image omitted; see the official code] Garage Doors | Garage doors shall not be permitted on a front facade. Ground Floor Windows and Doors | At least 25% of the ground floor facade facing a street shall be clear windows and doorways. Upper Floor Windows | Windows above the first story shall be vertical in proportion. Roof Design | Buildings with a pitched roof shall be permitted where the eaves are at least 20 feet from the ground and the roof pitch is a minimum of 4:12. (d) Apartment Buildings. Apartment buildings that contain only multiple-family dwellings shall meet the following design requirements. Multiple-family dwellings located in mixed-use buildings shall be subject to the general commercial/mixed-use building design requirements in Section 13.05(a). Apartment buildings are considered buildings with common entrances - where multiple family dwellings have individual entrances, they shall be subject to the townhouse design standards of Section 13.05(e) below. Apartment Buildings Entrance | There shall be a minimum of one pedestrian entryway facing the street or opening onto a courtyard facing the street. | [image omitted; see the official code] Front Stoop | A front stoop shall be allowed to project into the front yard. ADA-compliant access ramps that connect to the stoop may also project into the front yard. Windows and Doors | The front facade of all residential units shall be a minimum of 25% and a maximum of 75% windows and doors. Roof Design | Buildings with a flat roof appearance from the street shall have a decorative cornice. Buildings with a pitched roof shall be permitted where the eaves are at least 20 feet from the ground and the roof pitch is a minimum of 4:12. Parking | Off-street parking lots and carports or garages shall be located in the side or rear yard. (e) Townhouses. Attached/townhouse dwellings shall meet the following design requirements. Townhouse dwellings are dwellings where each unit has an individual front entrance - multiple family dwellings with common entrances shall be subject to the apartment building design standards of Section 13.05(d) above. Townhouses Entrance | Each dwelling shall provide a separate pedestrian entryway facing the front lot line with direct access to the sidewalk by way of a front porch or stoop with steps. | [image omitted; see the official code] Front Porch or Stoop | All dwellings shall include a front stoop or porch. The stoop or porch shall have a minimum depth of 4 feet and a minimum area of 24 square feet. Steps and ADA-compliant access ramps that connect to the stoop or porch may project into the front yard. First Floor Elevation | The stoop or porch shall be elevated a minimum of 21 inches above the sidewalk grade. This may be waived for units designed to be accessible by persons with disabilities. Windows and Doors | The front facade of all residential units shall be a minimum of 25% and a maximum of 50% windows and doors. Roof Design | Buildings shall be designed with a pitched roof with eaves at least 20 feet from the ground and a minimum roof pitch of 4:12. Garages | Attached or detached garages shall be located in the rear yard or on the rear side of the building and shall be accessed by a rear alley or drive. (f) Detached Single and Two Family Dwellings. Single family detached dwellings and duplex dwellings shall meet the following design requirements. Single-Family Detached and Duplex Dwellings Entrance | All buildings shall provide at least one (1) pedestrian door facing the front lot line. Two family dwellings may have one (1) unit with a door on the side. | [image omitted; see the official code] Front Porch or Stoop | All dwellings shall include a front porch or stoop with steps. A minimum depth of 6 feet and a minimum area of 48 square feet shall be provided on single-family detached dwellings and duplex dwellings. Duplex units may share a single front porch. First Floor Elevation | The first floor elevation shall be a minimum of 21 inches above the average exterior sidewalk elevation in front of the building. Windows and Doors | The front facade of all residential units shall be a minimum of 25% and a maximum of 50% windows and doorways. Roof Design | Buildings shall be designed with a pitched roof with eaves at least 20 feet from the ground and the roof pitch is between a minimum of 4:12 and a maximum of 12:12. Garages | Detached garages shall be located in the rear yard. Garages may be accessed by a rear alley or by driveways that pass through the side yard of the lot. Front facing attached garages shall be permitted, provided they don't project past the front building line and do not encompass more than 50% of the total building width. (g) Civic/Institutional Buildings. The design of an institutional or community service building, such as a school, government office, library, post office or place of worship is subject to review and approval by the plan commission. The intent is to allow flexibility in the design and siting of these unique buildings that serve a public use while ensuring their positive contribution to a desired community character as stated in the North End Plan. Civic/Institutional Buildings Front Setback | Civic/institutional buildings may exceed the maximum front yard setback of the district where a pedestrian plaza or landscaped front yard is provided. | [image omitted; see the official code] Front Facade | Walls that face a public street, plaza, green or park shall include windows and architectural features customarily found on the front of a building, such as awnings, cornice work, edge detailing or decorative finish materials. Entrance | There shall be a minimum of one (1) usable pedestrian entrance along the front public sidewalk. Main pedestrian entrances shall have design details that enhance the appearance and prominence of the entrance so that it is recognizable from the street and parking areas. Prominent Design | The standards for General and Mixed-Use Buildings contained in Section 13.04(a) shall be used as a basis for the design of civic/institutional buildings; however, the plan commission may permit modifications from these standards based upon the unique needs for the building and the desire to create unique landmark features with civic/institutional buildings. (h) Building Materials. All buildings shall contain quality building materials that are in keeping with the character of traditional buildings in Michigan City. Permitted materials for exterior walls (exclusive of windows and doors) that are clearly visible from the street or parking lot, shall be limited to the following: Building material | Primary building material | Trim material Brick or tile masonry (panel brick, tilt-up brick or textured paneling not permitted) | Permitted | Permitted Native stone (or synthetic equivalent) | Permitted | Permitted Stucco (cementitious finish) | Permitted | Permitted Wood lap siding, fiber cement siding or vinyl siding | Permitted | Permitted Pre-cast masonry (for trim and cornice elements only) | — | Permitted Gypsum Reinforced Fiber Concrete (GFRC)—for trim elements only | — | Permitted Exterior Insulation and Finish System (EIFS)—for trim elements only | — | Permitted Metal (for beams, lintels, trim elements and ornamentation only) | — | Permitted Split-faced block (only for piers, foundation walls and chimneys) | — | Permitted (1) Primary building material shall comprise at least 75 percent of the visible wall materials. Trim material shall comprise no more than 25 percent of the visible wall materials. Wall area calculations are exclusive of windows and doors. (2) Provided the appearance is in keeping with the traditional architectural character of Michigan City, other materials not listed above that are of the same or higher quality in terms of durability and appearance/texture similar to brick, stone, or wood may be approved by the plan commission. (3) Wall materials including panel brick, tilt-up brick textured paneling, plain, smooth-face, or scored concrete masonry units, corrugated metal paneling and fiberglass sheeting are prohibited for walls that are clearly visible from streets, parks, civic squares, and civic greens. (i) Awnings and Marquees. Storefronts and building entrances may be enhanced by awnings or marquees, which give shade and shelter or add color and visual interest to the entry or display window of the storefront, provided that the following conditions are met: (1) Awnings and marquees may project over a sidewalk; however, they must be a minimum of eight-foot clearance provided from the sidewalk. (2) Awnings and marquees shall be functional and provide shade or shelter for pedestrians over a substantial portion of the sidewalk. (3) Awnings shall be positioned immediately above ground floor windows and have a straight shed that projects from the building. (4) Awnings shall be constructed of durable materials such as canvas or steel that will not fade or tear easily. Plasticized, rigid, cubed or curved awnings or mansard style canopies are prohibited. Marquees shall be constructed of materials compatible with the building and meeting the trim material specifications of Section 13.05(h). (5) Awnings shall not be internally illuminated and any signs shall be illuminated by fixtures located above the awning and directed downward.
Ask a question about Michigan City law
Corpus searches the Michigan City sections it holds and shows the ones that match, with their citations. Free, no sign-in.