Sec. 34-95. - Exits.
(a) An exit is a continuous and unobstructed means of egress to safe ground outside of a building. Doors which form a part of a required means of egress shall be equipped with positive-latching, nonlocking-against-egress hardware and shall be not less than 36 inches in width in new construction, and not less than 30 inches in width in existing facilities. (b) The first floor of the home shall have at least two separate and independent means of egress leading to the outside. (c) Occupied room and exterior door hardware shall be positive latching, and nonlocking-against-egress. (d) Means of egress shall not pass through rooms containing furnaces or water heaters that produce an open flame.
(Code 1985, § 93.43; Ord. No. 3845, 7-5-1994)