For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 62-106 — Sewer construction methods and testing requirements

Code of Ordinances of the City of Mishawaka, Indiana (Codified through Ordinance No. 5932, enacted May 5, 2025. (Supp. No. 18)) · Mishawaka Municipal Code § 62-106

Corpus is an independent public-information project, not the official City of Mishawaka website. Stable reference: corpuslaw.us/code/6fe4faeb-74c0-4ef9-907d-54daac5b8a7a

Sec. 62-106. - Sewer construction methods and testing requirements.

All construction methods shall be in accordance with the latest edition of the City of Mishawaka Engineering Standards, as approved by the board of public works and safety. An infiltration/exfiltration test, signed and sealed by a licensed professional engineer, shall be performed on all sewers, including buildings sewers. The city engineer's office shall be notified at least 24 hours in advance of any testing, in order to be able to witness the tests. The maximum allowable infiltration rate is 100 gallons per inch diameter per mile of sewer per day, prorated to the length of the building sewer. In the event any manholes, or other structures are installed, they too shall be tested, with a maximum allowable infiltration rate of one-tenth-gallon per hour per foot of diameter per foot of head.

(Ord. No. 5265, § 2, 8-2-2010)

Ask a question about Mishawaka law

Corpus searches the Mishawaka sections it holds and shows the ones that match, with their citations. Free, no sign-in.