§ 155.33 — Light and ventilation
Code of Ordinances of the City of Muncie, Indiana (Codified through Ordinance No. 5-26 enacted January 5, 2026. (Supp. No. 34)) · Muncie Municipal Code § 155.33
Corpus is an independent public-information project, not the official City of Muncie website. Stable reference: corpuslaw.us/code/7bc9854a-6fcd-43e9-87f4-55a5cba5b127
Sec. 155.33. - Light and ventilation.
No person shall occupy as owner occupant, or let to another for occupancy, for the purposes of living therein, any dwelling, dwelling unit, rooming house, or rooming unit which does not comply with the following requirements: (A) Natural light in habitable room. Every habitable room shall have at least one window of approved size facing directly to the outdoors or to a court. The minimum total window area, measured between stops, for every habitable room shall be four percent of the floor area of such room, except in kitchens where artificial light be provided in accordance with the provisions of the building code or any other code or ordinance of the municipality applicable thereto. Whenever walls or other portions of a structure face a window of any room and such obstructions are located less than three feet from the window and extend to a level above that of the ceiling of the room, such a window shall not be deemed to face directly to the outdoors or to a court and shall not be included as contributing to the required minimum total window area for the room. (B) Light in non-habitable work space. Every laundry, furnace room, and all similar non-habitable work spaces located in a dwelling shall have one supplied electrical light fixture available at all times. (C) Light in public halls and stairways. Every public hall and inside stairway in every dwelling shall be adequately lighted at all times with an illumination of at least five lumens per square foot in the darkest portion of the normally traveled stairs and passageways. (D) Electric outlets required. Every habitable room of the dwelling shall contain at least two separate and remote outlets, one of which may be a ceiling or wall-type electric light fixture. In the kitchen, three electric separate such convenience outlets and one ceiling or wall-type electric light fixture shall be provided. Every public hall, water closet compartment, bathroom, laundry room, or furnace room shall contain at least one electric light fixture. In addition to the electric light fixture in every bathroom and laundry room, there shall be provided at least one electric outlet. (E) Adequate ventilation. Every habitable room shall have at least one window which can be easily opened, or such other device as will adequately ventilate the room. The total openable window area in every habitable room shall be equal to at least 45 percent of the minimum window area size required in (A) above, except where mechanical ventilation is provided in accordance with the provisions of the building code or any other code or ordinance of the municipality applicable thereto. (F) Ventilation and light in bathroom and water closet. Every bathroom and water closet compartment shall comply with the light and ventilation requirement for habitable rooms as required by (A) and (D) above, except that no window shall be required in bathrooms or water closet compartments equipped with an approved ventilation system.
(Ord. No. 15-02, 6-3-02)
Ask a question about Muncie law
Corpus searches the Muncie sections it holds and shows the ones that match, with their citations. Free, no sign-in.
