§ 18-31 — Amendments to electrical code
Code of Ordinances of the City of Garden City, Kansas (Codified through Ordinance No. 3053-2026, enacted August 4, 2026. (Supp. No. 36, 1-27, Update 1)) · Garden City Code of Ordinances § 18-31
Corpus is an independent public-information project, not the official City of Garden City website. Stable reference: corpuslaw.us/code/e08fb33a-a529-497e-9342-187d02074ed3
Sec. 18-31. - Amendments to electrical code.
The following sections of the Electrical Code adopted and incorporated by reference in this Article is hereby amended as follows: Section 210.8 Ground-Fault Circuit Interrupter Protection for Personnel. Amended to read as follows: Ground-fault circuit-interrupter protection for personnel shall be provided as required in 210.8(A) through (E). The ground-fault circuit-interrupter shall be installed in a readily accessible location. Informational Note No. 1: See 215.9 for ground-fault circuit-interrupter protection for personnel on feeders. Informational Note No. 2: See 422.5(A) for GFCI requirements for appliances. For the purposes of this section, when determining distance from receptacles, the distance shall be as the shortest path the cord of an appliance connected to the receptacle would follow through without piercing a floor, wall, ceiling, or fixed barrier, or passing through a door, doorway, or window. (A) Dwelling Units. All 125-volt, single-phase, 15- and 20- ampere receptacles installed in the locations specified in 210.8(A)(1) though (10) shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms; (2) Garages, and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use; (3) Outdoors; (a) Exception: Receptacles that are not readily accessible and are supplied by a branch circuit dedicated to electric snow-melting, deicing, or pipeline and vessel heating equipment shall be permitted to be installed in accordance with 426.28 or 427.22, as applicable. (4) Crawl spaces - at or below grade level; (5) Unfinished portions or areas of the basement not intended as habitable rooms; (a) Exception: A receptacle supplying only a permanently installed fire alarm or burglar alarm system shall not be required to have ground-fault circuit-interrupter protection. Any receptacle falling under this exception shall not be considered as meeting the requirements of 210.52(G). Informational Note No. 1: See 760.41(B) and 760.121(B) for power supply requirements for fire alarm systems. (6) Kitchens - where the receptacles are installed to serve countertop surfaces; (7) Sinks - where receptacles are installed within 1.8 meters or 6 feet from the top inside edge of the bowl of the sink; provided, however, that any non-accessible kitchen receptacle designated for a refrigerator shall not be required to be ground-fault circuit-interrupter protected; (8) Boathouses; (9) Bathtubs or shower stalls - where receptacles are installed within 1.8 meters or 6 feet of the outside edge of the bathtub or shower stall; (10) Laundry areas. (B) Other Than Dwelling Units. All single-phase receptacles rated 150 volts to ground or less, 50 amperes or less and three-phase receptacles rated 150 volts to ground or less, 100 amperes or less installed in the following locations shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms; (2) Kitchens; (3) Rooftops; (a) Exception: Receptacles on rooftops shall not be required to be readily accessible other than from the rooftop. (b) Exception: Receptacles that are not readily accessible and are supplied by a branch circuit dedicated to electric snow-melting, deicing, or pipeline and vessel heating equipment shall be permitted to be installed in accordance with 426.28 or 427.22, as applicable. (4) Outdoors; (a) Exception: Receptacles that are not readily accessible and are supplied by a branch circuit dedicated to electric snow-melting, deicing, or pipeline and vessel heating equipment shall be permitted to be installed in accordance with 426.28 or 427.22, as applicable. (b) Exception: In industrial establishments only, where the conditions of maintenance and supervision ensure that only qualified personnel are involved, an assured equipment grounding conductor program as specified in 590.6(B)(3) shall be permitted for only those receptacle outlets used to supply equipment that would create a greater hazard if power is interrupted or having a design that is not compatible with GFCI protection. (5) Sinks - where receptacles are installed within 1.8 meters or 6 feet from the top inside edge of the bowl of the sink; (a) Exception: In industrial laboratories, receptacles used to supply equipment where removal of power would introduce a greater hazard shall be permitted to be installed without GFCI protection. (b) Exception: For receptacles located in patient bed locations of general care (Category 2) or critical care (Category 1) spaces of health care facilities other than those covered under 210.8(B)(1), GFCI protection shall not be required. (6) Indoor wet locations; (7) Locker rooms with associated showering facilities; (8) Garages, service bays, and similar areas other than vehicle exhibition halls and showrooms; (9) Crawl spaces - at or below grade level; (10) Unfinished portions or areas of the basement not intended as habitable rooms. (C) Boat Hoists. GFCI protection shall be provided for outlets not exceeding 240 volts that supply boat hoists installed in dwelling unit locations. (D) Kitchen Dishwasher Branch Circuit. GFCI protection shall be provided for outlets that supply dishwashers installed in dwelling unit locations. (E) Crawl Space Lighting Outlets. GFCI protection shall be provided for lighting outlets not exceeding 120 volts installed in crawl spaces. Section 230.70(A)(1) Readily Accessible Location. Amended to read as follows: (a) The service disconnecting means for a One- or Two-Family Dwelling shall be installed at a readily accessible location either outside of a building or structure or inside nearest the point of entrance of the service conductors, not to exceed three feet (3') of wire from the meter. (b) The service disconnecting means for a building or structure other than a One- or Two-Family Dwelling shall be installed at a readily accessible location outside of a building or structure.
(Ord. No. 2861-2020, § 1, 3-17-20; Ord. No. 2872-2020, § 2, 8-4-20)
Ask a question about Garden City law
Corpus searches the Garden City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
