§ 18-61 — Amendments and deletions to fuel gas code
Code of Ordinances of the City of Garden City, Kansas (Codified through Ordinance No. 3053-2026, enacted August 4, 2026. (Supp. No. 36, 1-27, Update 1)) · Garden City Code of Ordinances § 18-61
Corpus is an independent public-information project, not the official City of Garden City website. Stable reference: corpuslaw.us/code/4b53a6c3-2560-4072-ba5b-fb70aacf8725
Sec. 18-61. - Amendments and deletions to fuel gas code.
The following sections of the fuel gas code adopted and incorporated by reference in this article are hereby deleted or amended to read as follows: Section 101.1 Title. Amended to read as follows: These regulations shall be known as the Fuel Gas Code of the City of Garden City, Kansas, hereinafter referred to as "this code". Section 106.6.2 Fee schedule. Amended to read as follows: The fees for fuel gas work shall be as indicated in the following schedule: Chapter 18, Section 18-6 of the Code of Ordinances. Section 106.6.3 Fee refunds. Deleted Section 108.4 Violation penalties. Amended to read as follows: Any person who violates a provision of this code, who fails to comply with any of the requirements thereof or who performs fuel gas work in violation of the approved construction documents, directive of the building official or of a permit or certificate issued under the provisions, shall be guilty of a Class C violation and punished as provided in amended Section 18-3. Each day that a violation continues after due notice has been served shall be deemed a separate offense. Section 108.5 Stop work orders. Amended to read as follows: Upon notice from the building official that fuel gas work is being done contrary to the provisions of this code or in a dangerous or unsafe manner, such work shall immediately cease. Such notice shall be in writing and shall be given to the owner of the property, the owner's agent, or to the person doing the work. The notice shall state the conditions under which work is authorized to resume. Where an emergency exists, the building official shall not be required to give a written notice prior to stopping the work. Any person who shall continue on the system after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be guilty of a Class C violation and punished as provided in amended Section 18-3. Section 403.4.3 Copper and copper alloy. Deleted Section 403.5.3 Copper and copper alloy tubing. Deleted Section 404.12 Minimum burial depth. Amended to read as follows: All underground piping systems shall be installed a minimum depth of twenty-four inches (24") below grade. Dielectric unions shall be used prior to entering a structure. Section 404.12.1 Individual outdoor appliances. Deleted Section 402.1 General considerations. Amended to read as follows: Piping systems shall be of such size and so installed as to provide a supply of gas sufficient to meet the maximum demand and supply gas to each appliance inlet at not less than the minimum supply pressure required by the appliance. Underground gas lines to the main structure shall be a minimum of one and one-quarter (1¼) inch pipe from meter to the point at which ground is broken. Aboveground gas lines shall be properly insulated from underground lines by an insulated union. A minimum three-quarter (¾) inch gas line shall be required to the first outlet. Branch piping shall be sized in accordance with the appropriate tables of Chapter 4. When it has been determined maximum gas requirements do not warrant the size of underground piping stipulated, and that further need will never occur, as in the case of a multifamily apartment, the building official shall have the authority to authorize the reduction of pipe size to one (1) inch. Section 404.13 Trenches. Amended to read as follows: The trench shall be graded so that the pipe has a firm, substantially continuous bearing on the bottom of the trench. The trench for the service line shall contain no other lines. A multiple dwelling shall require one service line for each unit, and no service line shall be extended from one building to another, nor from one part of a building to another. Section 406.4.1 Test pressure. Amended to read as follows: This inspection shall be made after all gas piping authorized by the permit has been installed and before any such piping has been covered or concealed, or any fixture or appliance has been attached thereto. This inspection shall require that the lines be pressured with a pressure of twelve inches (12") of mercury or twenty (20) pounds of air, thirty (30) pounds of air if CSST is used, and the same shall have stood for at least fifteen (15) minutes with no noticeable loss in pressure prior to the inspection. For welded piping, and for piping carrying gas at pressures in excess of fourteen inches (14") (356 mm) water column pressure, the test pressure shall not be less than sixty (60) pounds per square inch (413.4 kPa) and shall be continued for a length of time satisfactory to the administrative authority, but in no case for less than thirty (30) minutes. A tag denoting the pressure at which the system was pressurized to shall be left adjacent to the gauge. All necessary apparatus for conducting tests shall be furnished by the permit holder. Section 406.4.2 Test duration. Deleted
(Ord. No. 2861-2020, § 1, 3-17-20)
Ask a question about Garden City law
Corpus searches the Garden City sections it holds and shows the ones that match, with their citations. Free, no sign-in.