Sec. 15-54. - Amendments and additions.

The 2018 International Fire Code adopted by reference in section 15-52 is amended in the following respects: Section 101.1 is amended to read as follows: Section 101.1 Title. These regulations shall be known as the Fire Code of the Unified Government of Wyandotte County/Kansas City, Kansas, hereinafter referred to as "this Code." Section 101.2.1 is hereby deleted. Section 102.3 is amended to read as follows: Section 102.3 Change of use or occupancy. No change shall be made in the use or occupancy of any structure that would place the structure in a different division of the same group or occupancy or in a different group of occupancies, unless such structure is made to comply with the requirements of this Code and the International Building Code and/or NFPA 101 Life Safety Code. Subject to the approval of the fire code official, the use or occupancy of an existing structure shall be allowed to be changed and the structure is allowed to be occupied for purposes in other groups without conforming to all the requirements of this Code and the International Building Code for those groups, provided the new or proposed use is less hazardous, based on life and fire risk, than the existing use. Section 102.4 is amended to read as follows: Section 102.4 Application of building code. The design and construction of new structures shall comply with the International Building Code, and any alterations, additions, changes in use or changes in structures required by this Code, which are within the scope of the International Building Code, and/or NFPA 101 Life Safety Code, shall be made in accordance therewith. Section 109.1 is hereby deleted. See administrative provision chapter 8-25 Code of Ordinance, section 167 Board of Appeals. Section 112.4 is amended to read as follows: Section 112.4 Failure to comply. Any person who shall continue to work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be liable to a fine of not less than $100.00 or more than $2,500.00. Section 310.7.1 is amended/added to read as follows: Section 310.7.1 Smoking receptacles required. Owners of commercial and multi-family properties, where smoking is permitted, shall be responsible for providing approved receptacles for discarded smoking material in locations approved by authority having jurisdiction. Section 403.6 is amended/added to read as follows: Section 403.6 Group F and S1 Occupancies. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for buildings containing Group F or S1 occupancies where any of the following conditions apply: 1. The Group F or S1 occupancy has an occupant load of 500 or more persons. 2. The Group F or S1 occupancy has an occupant load of more than 100 persons above or below the level of exit discharge. 3. Group F pallet manufacturing and recycling facilities as required by section 2810. Section 403.6.1 Employee training. Employees shall be periodically instructed and kept informed of their duties and responsibilities under the plan. Records of instruction shall be maintained. Such instruction shall be reviewed by employees at intervals not exceeding 3 months. A copy of the plan shall be readily available at all times within the facility. Section 403.6.2 Drill frequency. Employees of S1 occupancies meeting the conditions of Section 406.3 shall participate in drills according to Section 405.2 under the Group F requirements. Section 503.3 is amended to read as follows: Section 503.3 Marking. Where required by the fire code official, approved signs and painted curb, or pavement if a curb is absent, shall be provided for fire apparatus access roads to identify such roads or prohibit the obstruction thereof. The means by which fire lanes are designated shall be maintained in a clean and legible condition at all times and be replaced or repaired when necessary to provide adequate visibility. The curb, or pavement if a curb is absent, shall be painted red, 4-inch wide stripes when pavement is marked, with white 3 inch letters indicating "NO PARKING FIRE LANE". Lettering shall occur every 25 feet of the fire lane. Signs used to indicate fire lanes shall meet the requirements of section D103.6 of the 2018 International Fire Code. Section 503.4.2 is amended/added to read as follows: Section 503.4.2 Authority to tow vehicles. The Fire Code Official shall have the authority to issue a municipal summons and/or tow illegal parked vehicles in designated fire apparatus access lanes and parked within 15-feet of a fire hydrant, at the owner's expense. Section 603.3.3.2 is amended/added to read as follows: Section 607.3.3.3.2 Fusible link replacement verification. When a commercial kitchen hood or duct system is inspected, the fusible links that were replaced shall be secured along the conduit leading to the manual pull station that initiates the suppression system. Section 901.6.3.1 is amended to read as follows: Section 901.6.3.1 Records information. Initial records shall include the name of the installation contractor, type, of components installed, manufacturer of the components, location and number of components installed per floor. Records shall also include the manufacturers' operation and maintenance instruction manuals. A record of the periodic inspections, tests, servicing, and other operations and maintenance shall be maintained on the premises or other approved location for the life of the installation. Records shall be made available for inspection by the fire code official, and a copy of the records shall be provided to the fire code official upon request. The fire code official has the authority to prescribe the form and format of such recordkeeping. The fire code official has the authority to require that certain required records including but not limited to automatic fire sprinkler systems, fire alarm systems, commercial kitchen hood suppression systems, commercial hood cleaning, active smoke control systems private fire hydrant systems, fire pumps, spray booths, special suppression systems, foam systems, and standpipes be filed with the fire code official. Section 912.3 is amended to read as follows: Section 912.3 Fire hose threads. Fire hose threads used in conjunction with standpipe systems and/or fire department connections shall be approved and shall be a 5-inch Storz connection on a 30-degree downward extension. Section 5608.3 is amended to read as follows: Section 5608.3 Approved fireworks displays. Approved fireworks displays shall include only the approved fireworks 1.3G, fireworks 1.4G, fireworks 1.4S and pyrotechnic articles 1.4G, which shall be handled by a minimum of 2 approved, competent operators. The approved fireworks shall be arranged, located, discharged and fired in a manner that will not pose a hazard to property or endanger any person. Appendix D, section D 107.1 is amended to read as follows: D107.1 One- or two-family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 75 shall be provided with separate and approved fire apparatus access roads and shall meet the requirements of Section D104.3. This requirement does not affect development plated prior to the effective date of this Code adoption. Exceptions: (1) Where there are 75 or more dwelling units on a single public or private fire apparatus access road and all dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3, access from two directions shall not be required. (2) The number of dwelling units on a single fire access road shall not be increased unless fire apparatus roads will connect with future development as determined by the fire code official.

(Ord. No. O-45-11, § 2, 10-20-2011; Ord. No. O-47-16, § 1, 7-28-2016; Ord. No. O-16-19, § 1, 3-7-2019; Ord. No. O-96-22, § 3, 6-30-2022)

Ask a question about Kansas City law

Corpus searches the Kansas City sections it holds and shows the ones that match, with their citations. Free, no sign-in.