§ 8-412 — Same—Amendments
Code of the Unified Government of Wyandotte County/Kansas City, Kansas (Supp. No. 52: codified through Ordinance No. O-61-26, passed May 21, 2026) · Kansas City, Kan., Unified Government Code § 8-412
Corpus is an independent public-information project, not the official City of Kansas City website. Stable reference: corpuslaw.us/code/bdb589d6-e613-4ad8-bab4-0055a9a0b3a9
Sec. 8-412. - Same—Amendments.
The 2018 International Residential Code for One- and Two-Family Dwellings, adopted by reference in section 8-411, is amended in the following respects: Sections R101.1—R114.2 of Chapter 1, Administration are hereby deleted. See administration provisions in section 8-25 of this chapter. Section R202 definition of carport, portable is added as follows: Carport, portable. A detached manufactured accessory building customarily used for the shelter or storage of vehicles and /or watercraft, including canopies used for such, which can be easily moved without disassembly, after removal of any tie-down or other anchoring provisions intended to compensate for wind displacement, and which is generally a frame covered by lightweight metal membrane material. See portable carports section R309.2. Section R301.2(1) Table is amended to read as follows: Section R301.2(1) International residential code data entry; Table R301.2(1) Climatic and Geographic Design Criteria. Table R301.2(1) shall include the following data: GROUND SNOW LOAD | WIND DESIGN | SEISMIC DESIGN CATE- GORY f | SUBJECT TO DAMAGE FROM | WINTER DESIGN TEMP e | ICE BARRIER UNDER- LAYMENT RE- QUIRED h | FLOOD HAZARD S g | AIR FREEZING INDEX i | MEAN ANNUAL TEMP j Wind Speed d (MPH) | Topo- graphic Effects k | Weathering a | Frost Line Depth b | Termite c 20 | 115 | No | A | Severe | 36 | Moderate to Heavy | 6°F | Yes | See Ch. 27 | 1000 | 54.7°F For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. The weathering column shall be filled in with the weathering index (i.e., "negligible," "moderate" or "severe") for concrete as determined from the Weathering Probability Map [Figure R301.2(3)]. The grade of masonry units shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652. b. The frost line depth may require deeper footings than indicated in Figure R403.1(1). The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [Figure R301.2(4)A]. Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 97½-percent values for winter from Appendix D of the International Plumbing Code. Deviations from the Appendix D temperatures shall be permitted to reflect local weather experience as determined by the Building Official. f. The jurisdiction shall fill in this part of the table with the Seismic Design Category determined from Section R301.2.2.1. g. The jurisdiction shall fill in this part of the table with (a) the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the currently effective FIRMs and FBFM, or other flood hazard map adopted by the community, as may be amended. h. In accordance with Sections R905.2.7.1, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall fill in this part of the table with "NO." i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99%) value on the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32° Fahrenheit)" at www.ncdc.noaa.gov/fpsf.html. j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32° Fahrenheit)" at www.ncdc.noaa.gov/fpsf.html. k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effect, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table. R302.1 is amended to read as follows: 302.1 Exterior walls. Construction, projections, openings, and penetrations of exterior walls of dwellings and accessory buildings shall comply with Table R302.1(1). Table R302.1(2) is deleted. Table 302.1 (1) Exterior walls shall be used. R302.2 is amended to read as follows: R302.2 Townhouses. Each townhouse shall be considered a separate building and shall be separated by fire-resistance-rated wall assemblies meeting the requirements of section R302.1 for exterior walls. Exceptions: A common 2-hour fire-resistance-rated wall assembly tested in accordance with ASTM E 119 or UL 263 is permitted for townhouses if such walls do not contain plumbing or mechanical equipment, ducts or vents in the cavity of the common wall. The wall shall be rated for fire exposure from both sides. And shall extend to and be tight against exterior walls and the underside of the roof sheathing. Electrical installations shall be installed in accordance with Chapters 34 through 43. Penetrations of electrical outlet boxes shall be in accordance with section R302.4. R302.2.4-6 Structural Independence. R302.2.4-6 Exception 5 is amended to read as follows: Exception 5. Townhouses separated by a common 2-hour fire resistance rated wall as provided by section 302.2 R302.3 is amended to read as follows: R302.3 Two-Family Dwellings. Two-Family Dwelling units shall be constructed and separated in accordance with the requirements of townhomes as set forth in this code. R302.3. Exception 1 is deleted. R302.4.2 Membrane Penetrations. Exception 2-2.1 is amended to read as follows: R302.4.2 Exception 2(2.1) By a horizontal distance of not less than 24 inches (610 mm) except at walls or partitions constructed using parallel rows of studs or staggered studs. Section R302.5.2 Duct Penetration is amended to read as follows: Section R302.5.2 Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gauge (0.48 mm) sheet steel or other approved material and shall have no openings into the garage. Exception: Supply duct openings may be permitted; provided the openings are protected by a minimum 20-minute rated fire damper(s). Table 302.6 is amended to read as follows: Table 302.6 DWELLING/GARAGE SEPARATION SEPARATION | MATERIAL From the residence and attics | Not less than ⅝-inch Type X gypsum board or equivalent applied to the garage side. From all habitable rooms above the garage | Not less than ⅝-inch Type X gypsum board or equivalent applied to the garage side. Structure(s) supporting floor/ceiling assemblies used for separation required by this section | Not less than ⅝-inch Type X gypsum board or equivalent applied to the garage side. Garages located less than 3 feet from a dwelling unit on the same lot | Not less than ⅝-inch Type X gypsum board or equivalent applied to the interior side of the exterior walls within this area. Attic access panels. | Not less than ⅝-inch Type X gypsum board or equivalent Materials approved for 1 hour fire resistive construction. Pull down stairs | Shall be rated or be adequately protected with not less than Type ⅝-inch Type X gypsum or equivalent materials approved for 1 hour fire resistive construction. Section R303.4 of the 2018 International Residential Code is hereby amended to read as follows: R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than three (3) air changes per hour when tested with a blower door at a pressure of 0.2 inch w.c. (50 Pa) in accordance with Section N1102.4.1.2, the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1505.4. (History: Ord. BC-2936 § 36, 2012) Section R306.5 is added to read as follows: Section R306.5 New Single-family dwellings toilet facilities. Toilet facilities shall be provided within 500 feet (measured from the property line adjacent to the street for platted subdivisions along the public way) for all new single-family dwellings starting from the time of the first footing inspection until facilities are available in the dwelling. If the facilities are not located on the job site, the location of the required facilities shall be posted on the job site or other certification provided to the building official to verify the availability of toilet facilities. The facilities on the site shall be removed prior to issuance of a temporary certificate of occupancy. R309.2 Carports is added to read as follows: R309.2 Carports. Carports shall be open on at least two sides. Carport floor surfaces shall be of approved noncombustible material. Carports not open on at least two sides shall be considered a garage and shall comply with the provisions of this section for garages. Exceptions: 1: Portable carports shall be assembled to comply with the manufacturer's instructions and anchored to the ground in compliance with one of the following methods. At a minimum there must be an anchoring point on each side of the carport for every 50 square feet of area covered by the carport. 1) One continuous 8 inches wide by 36 inches deep concrete stem wall on each longitudinal side of the carport with threaded anchor bolts embedded to match the carport manufacturer's recommended anchorage spacing. 2) A 4 inches thick concrete slab that extends beyond the perimeter of the carport in each direction with threaded anchor bolts embedded in the slab, deepened to 8 inches at each anchorage location, to match the carport manufacturer's recommended spacing. 3) Bolting the support legs, or adjacent cross support, to an existing concrete slab that is a minimum of 4 inches thick, to match the carport manufacturer's recommended anchorage spacing. The method of attaching the upright frame to the slab must be shown in the application for building permit. 4) Install concrete footings under each leg and bolt the legs, or adjacent cross support, to the new footings with threaded anchor bolts embedded to match the carport manufacturer's recommended anchorage spacing. The new footings are to be approximately 1 foot × 1 foot × 2 foot deep. The method of attaching the upright frame to the footing must be shown in the application for building permit. 5) An alternate anchoring design that provides a permanently paved hard surface floor and anchors the portable carport to the ground and that is approved by the building official. If an alternative method is proposed, complete installation details must be provided for review. The plans and details submitted must clearly indicate the method of anchoring and the flooring to be used. If new concrete footings are to be installed, they must be inspected when formed and prior to pouring of concrete. In all cases, a final inspection must be requested by the applicant. Fabric covered carports: All fabric covered carports or similar facilities shall comply with City setback requirements in the zone in which they are located. Unless the facility is considered a structure under the Building Code, no building permit shall be required for their placement. Fabric covered facilities shall be properly maintained, cleaned, and repaired as necessary. There shall be no electricity or other utilities provided to fabric covered carports, or similar facilities. Section R309.5 Fire sprinklers in private garages is amended to read as follows: R309.5 Fire sprinklers are optional in private garages. The garage walls shall be designed based on Table R302.1(1). Sprinklers in garages shall be connected to an automatic sprinkler system that complies with section P2904. Garage fire sprinklers shall be residential sprinklers or quick response sprinklers, designed to provide a density of 0.05 gpm/sq. ft. garage doors shall not be considered with respect to sprinkler placement. Section R312.1.1 is amended to read as follows: Section R312.1.1 Guards required. Guards shall be located along open- sided walking surfaces, including stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically from the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge of the open side. Insect screening shall not be considered as a guard. In addition, guards are required at retaining walls over 30 inches above grade when walking surfaces are within ten feet of the high side of the retaining wall. Section R313.1 Townhouse automatic sprinkler systems, is amended to read as follows: R313.1 An automatic fire sprinkler system is optional in townhouses. R313.2 1 and 2 family dwellings automatic fire systems, is amended to read as follows: R313.2 An automatic sprinkler system is optional in 1 and 2 family dwellings. Fire sprinkler system design for 1 and 2 family dwellings shall comply with section P2904 or NFPA 13D. Section R326.2 is added to read as follows: R326.2 Swimming Pools and Spas shall be protected by barriers per Section 305, Barrier Requirements, of the 2018 ISPSC, International Swimming Pool and Spa Code as published by the International Code Council, Inc., excepting only such parts or portions thereof as are specifically deleted or amended by this Section. Section 305.2.1,1 Barrier Height and Clearance: The top of the barrier shall not be less than 72 inches above grade where measured on the side of the barrier that faces away from the pool or spa. Section R402.1 Wood Foundations: R402.1 Wood Foundation systems are not allowed. All other references in this code to wood foundations systems are null and void. Section R403.1.1 Footing reinforcement is amended to read as follows: Section R403.1.1.1. Continuous footing reinforcement. Continuous footings for basement foundation walls shall have minimum continuous reinforcement consisting of not less than two No. 4 bars, uniformly spaced, located a minimum of three inches (76 mm) clear from the bottom of the footing. Section R403.1.1.2 Column pads is added to read as follows: Section R403.1.1.2 Column pads. Column pads shall be a minimum of 24 inches (610 mm) by 24 inches (610 mm) and eight inches (203 mm) deep. Reinforcement shall consist of a minimum of three No. 4 bars each way, uniformly spaced. Section R404.4 Retaining walls is amended to read as follows: Section R404.4 Retaining walls that are not laterally supported at the top and that retain in excess of 48 inches of unbalanced fill shall be designed t ensure stability against overturning, sliding, excessive foundation pressure and water uplift. Retaining walls shall be designed for a safety factor of 1.5 against later sliding and overturning. Section R405.1.2 Water discharge is added to read as follows: Section R405.1.2 Water discharge. Roof water and water from intermittent sources such as sump pumps, foundation drains, gutters downspouts and similar sources shall not discharge closer than three (3) feet from the foundation or to an approved drainage system. Section R801.3 Roof drainage is amended to read as follows: Section R801.3 Roof drainage. All dwellings shall have a controlled method of water disposal from roofs that will collect and discharge all roof drainage to the ground surface at least 3 feet from foundation walls or to an approved drainage system. Part IV Energy Conservation. Table N1102.1.2 (R402.1.2) is hereby amended to read as follows: TABLE N1102.1.2 (R402.1.2) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT a CLIMATE ZONE | FENESTRATION U-FACTOR b | SKYLIGHT U-FACTOR b | GLAZED FENESTRATION SHGC b | CEILING R-VALUE g | WOOD FRAME WALL R-VALUE | MASS WALL R-VALUE f | FLOOR R-VALUE e | BASEMENT WALL R-VALUE c | SLAB R-VALUE & DEPTH d | CRAWL SPACE WALL R-VALUE c 4 | 0.32 | 0.55 | 0.40 | 49 | 15 | 8/13 | 19 | 10/13 | 10, 2 ft | 10/13 For SI: 1 foot - 304.8 mm NR = Not Required a. R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the installed R-value of the insulation shall not be less that the R-value specified in the table. b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. c. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement walls. d. For heated slabs, R-5 insulation shall be provided under the full slab area and shall be added to the slab edge. e. Or insulation sufficient to fill the framing cavity, R-19 minimum. f. The second R-value applies when more than half the insulation is on the interior of the mass wall. g. Loose-fill-insulation shall be installed at the rate recommended by the manufacturer's statement "so many bags per 1000 sq ft". Where the pitch of the roof restricts the "minimum thickness" at the exterior wall line, the insulation shall be blown into the cavity so as to achieve a greater compacted density to a point where the "minimum thickness" can be achieved. An alternative is to install high-density batts around the perimeter edge per N1102.2. Table N1102.41-Under Climate Zone 4, amend the following item: Section N1102.4.1.2. Testing is amended to read as follows: Section N1102.4.1.2. Testing The building or dwelling unit shall have an air leakage rate of not exceeding 5 air changes per hour when tested with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Building leakage testing shall be conducted where required by the building official. Testing shall be conducted in accordance with RESNET/ICC 380, ASTM E779 or ASTM E1827 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Where required by the building official, the testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the building official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, back draft, and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test, shall be open; 4. Exterior or interior terminations for continuous ventilation systems shall be sealed; 5. Heating and cooling system(s), where installed at the time of the test, shall be turned off; and 6. Supply and return registers, where installed at the time of the test shall be fully open. Section N1102.4.4 Rooms containing fuel-burning appliances is deleted. Section N1103.3.5 Building Cavities is amended to read as follows: N1103.3.5 Building cavities. Building framing cavities are permitted to be used as supply ducts. Building framing cavities used as ducts or plenums shall be sealed to prevent leakage through the thermal envelope. Table N1106.4 (R406.4) is amended to read as follows: Table N1106.4 (R406.4) MAXIMUM ENERGY RATING INDEX CLIMATE ZONE | ENERGY RATING INDEX a 4 | 75 a. Where on-site renewable energy is included for compliance using ERI analysis of Section N1106.4, the building shall meet the mandatory requirements of Section 1106.2, and the building thermal envelope shall be greater than or equal to the levels of efficiency and SHGC in Table N1102.1.2 or Table N1102.1.4. Sections M2001, M2002, M2003, and G2452 (Boilers) are deleted. Section G2408.7 is added to read as follows: Section G2408.7 Liquefied petroleum gas piping shall not serve any gas water heater or appliance located in a pit or basement where heavier than air gas might collect to form a flammable mixture. Water heaters or appliances so served shall not be installed in an above-grade under-floor space or basement unless such location is provided with an approved means for removal of unburned gas. Section G2411.3 Arc-resistant CSST is deleted. Section G2414.5 is amended to read as follows: Section G2414.5 Metallic tubing. Seamless copper, aluminum alloy or steel tubing shall not be utilized for the distribution of fuel gas. Stainless steel tubing may be utilized when approved by the building official. Section G2414.5.2 is amended to read as follows: Section G2414.5.2. Copper tubing. Copper and brass tubing shall not be utilized to distribute natural gas nor shall it utilized to distribute any other fuel gas within a building or structure. G2417.4. Test Pressure Measurement is amended to read as follows: G2417.4.1 (406.4.1) Test pressure. This inspection shall include an air, C02, or nitrogen pressure test of not less than 10 pounds per square inch (68.9 kPa) gauge pressure. Part VII, Chapter 25, Plumbing Administration, is deleted. Section P2603.5.1 Sewer depth is amended to read as follows: Section P2603.5.1 Sewer depth. Building sewers shall be installed not less than 12 inches (305 mm) below the surface of the ground. Section 2706.1.2. Standpipes is amended to read as follows: P2706.1.2 Standpipes. Standpipes for automatic clothes washers shall extend a minimum of 30 inches (762 mm) and a maximum of 42 inches (1067 mm) above the finished floor. The trap for a clothes washer standpipe shall be installed at a minimum of 6 inches (150 mm) maximum of 18 inches (457 mm) above the finished floor. Access shall be provided to all standpipe traps and drains for rodding. Section P2708.2 Shower drain is amended to read as follows: Section P2708.2 Shower drain. Shower drains shall have an outlet of not less than 2 inches (51 mm). Section P2902.5.3 is amended to read as follows: Section P2902.5.3 Lawn irrigation systems. The potable water supply to lawn irrigation systems shall be protected against backflow by a device approved by the Board of Public Utilities, Kansas City, Kansas, Water Department. Section P2903.5 is amended to read as follows: Section P2903.5 Water hammer. The flow velocity of the water distribution system shall be controlled to reduce the possibility of water hammer. Water-hammer arrestor shall be installed where quick-closing valves are utilized. Water hammer arrestors shall be installed in accordance with manufacturer's installation instructions. Water hammer arrestors shall conform to ASSE 1010. Exception: Each water supply line to a fixture, except tank type water closets, may terminate with an air chamber. All air chambers shall be placed in a vertical position in a tee opening. Each air chamber shall be not less than 12 inches in length and of a diameter not less than the branch it serves. Section P2903.8.2 is amended to read as follows: Section P2903.8.2 Minimum size. Where the developed length of the distribution line is 60 feet (18,288 mm) or less, and the available pressure at the meter is a minimum of 40 lbs. per square inch (276 kPa), the minimum size of individual distribution lines shall be not less than ½ inch (12.7 mm) diameter. Certain fixtures such as one-piece water closets and whirlpool bathtubs shall require a larger size where specified by the manufacturer. If a water heater is fed from the end of a cold-water manifold, the manifold shall be one size larger than the water heater feed. Section P2906.4 is amended to read as follows: Section P2906.4 Water service piping. Approval, inspection, materials and testing of water service piping shall be in accordance with the policies prescribed by the Board of Public Utilities, Kansas City, Kansas, Water Department. If there is an occurrence that a system might meet the definition of water service pipe under this code and not be under the jurisdiction of the Board of Public Utilities, such water service pipe shall conform to NSF 61 and shall conform to one of the standards listed in table P2905.4. Water service pipe or tubing installed underground and outside of the structure shall have a minimum working pressure rating of 160 psi at 73 degrees Fahrenheit (1,103 kPa at 23 degrees C). Where the water pressure exceeds 160 pounds per square inch (1,103 kPa), piping material shall have a rated working pressure equal to or greater than the highest available pressure. Water service piping materials not third-party certified for water distribution shall terminate at or before the full open valve located at the entrance to the structure. Ductile iron water service piping shall be cement mortar lined in accordance with AWWA C104. Section P2906.4.2 is amended to read as follows: Section P2906.4.2 Water service installation. Installation of water service piping shall be in accordance with the policies prescribed by the Board of Public Utilities, Kansas City, Kansas, Water Department. If there is an occurrence that a system might meet the definition of water service pipe under this code and not be under the jurisdiction of the board of public utilities, trenching, pipe installation and backfilling shall be in accordance with section P2604.2. Water service pipe is permitted to be located in the same trench with a building sewer provided such sewer is constructed of materials listed for underground use within a building in section P3002.1. If the building sewer is not constructed of materials listed in section P3002.1, the water service pipe shall be separated from the building sewer by a minimum of 5 feet (1,524 mm), measured horizontally, of undisturbed or compacted earth or placed on a solid ledge at least 12 inches (305 mm) above and to one side of the highest point in the sewer line. Exception: the required separation distance shall not apply where a water service pipe crosses over a sewer pipe, provided that the water service pipe is sleeved to at least 5 feet (1,524 mm), horizontally from the sewer pipe centerline, on both sides of the crossing with pipe materials listed in Tables P2905.4, P3002.1(1), or P3002.2. Section P2905.5.1 is added as follows: Section P2905.5.1 Under concrete slabs. Inaccessible water distribution piping under slabs shall be copper water tube minimum Type L, brass, ductile iron pressure pipe, galvanized steel pipe, chlorinated polyvinyl chloride (CPVC) or crosslinked polyethylene (PEX) plastic pipe or tubing—all to be installed with approved fittings or bends. The minimum pressure rating for plastic pipe or tubing installed under slabs shall be 100 psi at 180 degrees Fahrenheit (689 kPa at 82 degrees Celsius). Section 2906.6.1 Saddle tap fittings is deleted. Table P3002.2 Building Sewer Pipe is amended as follows: Table P3002.2 Building Sewer Pipe. Delete "PS 25, SDR 41 (PS 28), PS 35, SDR 35 (PS 46), PS 50, PS 100" from "Polyvinyl chloride (PVC) plastic pipe in sewer and drain diameters". (Remainder of Table unamended.) Section P3005.4.2 is amended to read as follows: Section P3005.4.2 Building drain and sewer and slope. Pipe sizes and slope shall be determined from table P3005.4.2 on the basis of drainage load in fixture units (DFU) computed from table P3004.1. The minimum size of a building sewer serving a dwelling unit shall be 4 inches. Section P3102.1 is amended to read as follows: Section P3102.1 Main vent required. Every building shall have a main vent that is either a vent stack or a stack vent. Such vent shall run undiminished in size and as directly as possible from the building drain through to the open air above the roof. The minimum size of a main vent for a dwelling unit shall be 3 inches. P3105 Fixture Vents. P3105.1 Distance of trap from vent. Exception is deleted. Section P3114.3 is amended to read as follows: Section P3114.3 Where permitted. Individual vents, branch vents, circuit vents and stack vents shall be permitted to terminate with a connection to air admittance valve only when it is structurally not feasible to install a hard-piped venting system and approved by the building official. In existing construction, where the existing vent system is not accessible to the fixture location without the removal of finish materials or other existing construction. Individual- and branch-type air admittance valves shall conform to ASSE 1051. Individual and branch type air admittance valves shall vent fixtures that are on the same floor level and connect to a horizontal branch drain. Section P3114.5 is amended to read as follows: Section P3114.5 Access and ventilation. All air admittance valves shall be readily accessible. The valve shall be located in a ventilated space that allows air to enter the valve. Section E3601.6.2 is amended to read as follows: Section E3601.6.2 Service disconnect location. The service disconnecting means shall be installed at a readily accessible location either outside of a building or inside nearest the point of entrance of the service conductors. When service entrance conductors are more than 10 feet in length from the point of entry to the service panel, a separate means of disconnect must be installed at the service cable entrance to the building or structure. Service disconnecting means shall not be installed in bathrooms or closets. Each occupant shall have access to the disconnect serving the dwelling unit in which they reside. Section E3902.2 Garage and accessory building receptacles is amended to read as follows: Section E3902.2 Garage and accessory building receptacles. All 125 volt, single-phase, 15- and 20-amp receptacles installed in garages and grade level portions of unfinished accessory buildings used for or work areas shall have ground fault circuit- interrupter protection for personnel. [210.8(A)(3)] Exceptions: 1. A dedicated receptacle supplying only a permanently installed fire alarm or burglar alarm system. 2. A dedicated receptacle supplying only a garage door opener. 3. A dedicated receptacle supplying only a refrigerator and/or freezer. 4. A dedicated receptacle supplying a sump pump. Section E3902.5 Unfinished basement receptacles is amended to read as follows: Section E3902.5 Unfinished basement receptacles. All 125 volt, single-phase, 15- and 20-amp receptacles unfinished basement areas shall have ground fault circuit- interrupter protection for personnel. [210.8(A)(3)] Exceptions: 1. A dedicated receptacle supplying only a permanently installed fire alarm or burglar alarm system. 2. A dedicated receptacle supplying only a garage door opener. 3. A dedicated receptacle supplying only a refrigerator and/or freezer. 4. A dedicated receptacle supplying a sump pump. Section E3902.16 Arc-fault circuit interrupter protection. Exception is added as follows: Section E3902.16 Exception: AFCI protection is not required for the smoke detector/fire alarm circuit. Section E3902.13 Exception is added as follows: E3902.13 Arc-fault circuit interrupter protection for branch circuit extensions or modifications. Exception: This section will not apply where existing dwelling unit premises wiring circuits make the application of this section impracticable, as determined by the building official. Informational Note: Two examples of the application of this exception are where the existing dwelling unit has a multi-wire branch circuit or utilizes a listed panelboard for which there is no listed device for the application of AFCI protection. Section E3907.9 is added as follows: Section E3907.9 Cabinets and panelboards shall not be located in a bathroom or closet. E4002.14 Tamper-resistant receptacles is deleted. Section AJ501.8.4 Appendix J Stairs (Existing Buildings) is added as follows: Section AJ501.8.4 Appendix J Stairs (Existing Buildings). Any alteration to or the replacement of an existing stairway in an existing structure shall not be required to comply with the requirements of a new stairway as outlined in section R311.7 where the existing space and construction will not allow a reduction in pitch or slope.
(Code 1988, § 8-335; O-57-04, § 25, 9-16-2004; Ord. No. O-44-11, § 23, 10-20-2011; Ord. No. O-29-12, § 23, 5-3-2012; Ord. No. O-48-16, § 1, 7-28-2016; Ord. No. O-97-22, § 2, 6-30-2022)
Ask a question about Kansas City law
Corpus searches the Kansas City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
