For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-635 — Procedures

Code of the Unified Government of Wyandotte County/Kansas City, Kansas (Supp. No. 52: codified through Ordinance No. O-61-26, passed May 21, 2026) · Kansas City, Kan., Unified Government Code § 8-635

Corpus is an independent public-information project, not the official City of Kansas City website. Stable reference: corpuslaw.us/code/88bb0646-2d43-48ef-bc1f-914f03984bb4

Sec. 8-635. - Procedures.

(a) Timing of stormwater treatment facility construction. Stormwater treatment facilities shall be constructed as early as feasible during the development process. However, since some commonly used stormwater treatment facilities are sensitive to construction generated silt when upstream areas are under construction, the following provisions are allowable for timing of such facility construction: (1) For a stormwater treatment facility serving a single building lot, the facility shall be constructed concurrently with the development of the site and building, subject to exceptions set forward in this section. (2) When stormwater treatment facilities serve multiple development lots within a common plan of development, a stormwater treatment facility can be final graded, and permanent vegetation installed only after 90 percent of the land area served by the facility has achieved permanent stabilization unless the county engineer approves a shortened schedule. Additionally, stormwater treatment facilities must be installed and certified within six months of permanent stabilization of the entire land area served by the facility. Land area served by the facility shall mean those areas served by the facility within the common plan of development and shall not include offsite areas even if they are tributary to the facility. (3) For stormwater treatment facilities serving multiple development lots within a common plan of development, no certificate of occupancy and/or temporary certificates of occupancy shall be issued for any building or site unless a stormwater treatment facility has received a post construction certification per section 8-637(a)(1). (b) Failure to construct a required stormwater treatment facility. When construction of a stormwater treatment facility is delayed beyond the limits as provided in this section, the county engineer may utilize any or all of the following enforcement mechanisms: (1) Withhold issuance of building permits for properties proposed to be served by such stormwater treatment facility; (2) Withhold issuance of temporary and/or certificates of occupancy or certificates of compliance for permitted work that is proposed to be served by such stormwater treatment facility; and/or (3) Issue stop work orders for permitted work for any or all property that is proposed to be served by such stormwater treatment facility.

(Ord. No. O-81-21, § 2, 6-24-2021)

Ask a question about Kansas City law

Corpus searches the Kansas City sections it holds and shows the ones that match, with their citations. Free, no sign-in.