§ 8-657 — Same—Amendments
Code of the Unified Government of Wyandotte County/Kansas City, Kansas (Supp. No. 52: codified through Ordinance No. O-61-26, passed May 21, 2026) · Kansas City, Kan., Unified Government Code § 8-657
Corpus is an independent public-information project, not the official City of Kansas City website. Stable reference: corpuslaw.us/code/a83dcd29-7f54-48b6-84d8-727ebdb45eea
Sec. 8-657. - Same—Amendments.
The International Existing Building Code (2018), promulgated by the International Code Council, is adopted and incorporated in this article by reference as if fully set forth, except as it is amended by the following provisions of this section. Provisions of this article are in addition to the provisions of the International Existing Building Code. The following provisions coinciding with provisions of the International Existing Building Code supersede, or delete, when indicated, the corresponding provisions of the International Existing Building Code. All references within the model codes to any building, electrical, gas, mechanical, plumbing, sewage disposal, elevator, energy conservation, or existing building code shall be construed to be a reference to the respective building, electrical, gas, mechanical, plumbing, elevator, energy conservation, or existing building code specifically adopted by reference in articles II through XIV of this chapter. Chapter 1, Scope and Administration — This chapter is deleted. (See Article I of this chapter): Section 401.3 Flood hazard areas is deleted. See Code of Ordinances chapter 27, floodplain management. Section 502.3 Flood hazard areas is deleted. See Code of Ordinances chapter 27, floodplain management. Section 505.2 Replacement window opening control devices is hereby deleted. Section 701.3 Flood hazard areas is deleted. See Code of Ordinances chapter 27, floodplain management. Section 702.4 Replacement window opening control devices is hereby deleted. Section 803.2 Automatic sprinkler systems is amended to read as follows: Section 803.2 Automatic sprinkler systems. Automatic sprinkler systems, related monitoring and notification shall be provided throughout buildings undergoing Level 2 alterations that include exits or corridors shared by more the one tenant or that serve an occupant load greater than 30 where all the following conditions occur: 1. The work area is required to be provided with automatic sprinkler protection in accordance with the International Building Code as applicable to new construction. 2. The work area exceeds 50 percent of the floor area of the building. Exception: If the building does not have sufficient municipal water supply for design of a fire sprinkler system available to the floor without installation of a fire pump, work areas shall be protected by an automatic smoke detection system throughout all occupiable spaces other than sleeping units or individual dwelling units that activates the occupant notification system in accordance with Sections 907.4 907.5 and 907.6 of the International Building Code. Section 803.2.1 Windowless stories. Work located in a windowless story, as determined in accordance with the International Building Code, shall be sprinklered where the work area is required to be sprinkled under the provisions of the International Building Code for newly constructed buildings and the buildings have sufficient municipal water supply without installation of a new fire pump. Section 1011.7.2.1 Stairways is amended to read as follows: Section 1011.7.2.1 Stairways. Means of egress stairways shall be enclosed as required by the International Building Code or in accordance with Section 1011.4. Section 1103.3 Flood hazard areas is deleted. See Code of Ordinances chapter 27, floodplain management. Section 1201.4 Flood hazard areas is deleted. See Code of Ordinances chapter 27, floodplain management.
(Ord. No. O-95-22, § 17, 6-30-2022)
Ask a question about Kansas City law
Corpus searches the Kansas City sections it holds and shows the ones that match, with their citations. Free, no sign-in.