Sec. 19-605. - Prevention devices required.
(a) An approved backflow prevention device shall be installed on each service line, at the customer's expense, to a customer's water system serving premises where, in the judgment of the city municipal services and operations department or authorized representative or the state department of health and environment, actual or potential uncontrolled cross connections exist. (b) Approved devices to protect against backflow or backsiphonage shall be installed at all fixtures and equipment where backflow and/or backsiphonage may occur and where there is a hazard to the potable water supply in that polluted water or other contaminating materials may enter into the public water supply. (c) (1) The type and degree of protection required shall be commensurate with the degree of hazard and/or type of contamination that may enter the public potable water system, in accordance with KDHE and EPA criteria, adopted plumbing code, as well as this article. (2) The following is a nonexhaustive list that, includes, but is not limited to, certain facilities where backflow protection is required, due to potential hazards to both the public and private piping system, at both the service connection and within the building: a. Hospitals—RP. b. Funeral homes, morgues and mortuaries—RP. c. Medical clinics—RP. d. Industrial, medical and institutional laboratories—RP. e. Plating and chemical plants—RP. f. Metal manufacturing, cleaning and fabricating—RP. g. Oil and gas production, storage and transmission facilities—RP. h. Breweries and beverage bottling plants—RP i. Radioactive materials plants—Air gap. j. Aircraft plants—RP. k. Plastic injection and molding plants—RP. l. Multi-storied buildings with booster pump—DCVA. m. Fire systems: 1. Contamination hazard—RP. 2. Pollution hazard—DCVA. n. Car wash facilities—RP. o. Restricted, classified or other closed facilities—RP. p. Facilities in which the piping system cannot be traced—RP. q. Facilities employing water pressure boost pumps: 1. Contamination hazard—RP. 2. Pollution hazard—DCVA.
(Code 2018, § 19-705; Ord. No. 9859)
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.