§ 5-1005 — International Fuel Gas Code—Section 303.3 amended
Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-1005
Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/3e8ba1b4-c834-4157-b9e1-ff040c02087b
Sec. 5-1005. - International Fuel Gas Code—Section 303.3 amended.
Section 303.3 of the 2018 International Fuel Gas Code is hereby amended to read as follows: 303.3 Prohibited locations. Appliances shall not be located in sleeping rooms, bathrooms, toilet rooms, hot tub rooms, storage closets or surgical rooms, or in a space that opens only into such rooms or spaces, except where the installation complies with one of the following: 1. The appliance is a direct-vent appliance installed in accordance with the conditions of the listing and the manufacturer's instructions. 2. Vented room heaters, wall furnaces, vented decorative appliances, vented gas fireplaces, vented gas fireplace heaters and decorative appliances for installation in vented solid fuel-burning fireplaces are installed in rooms that meet the required volume criteria of section 304.5. 3. A single wall-mounted unvented room heater is installed in a bathroom and such unvented room heater is equipped as specified in section 621.6, has an input rating not greater than 6,000 BTU/h (1.76 kW), and a carbon monoxide detector, meeting the requirements of section R315 of the 2018 International Residential Code, is installed in the same room as the appliance. The bathroom shall meet the required volume criteria of section 304.5. 4. A single wall-mounted unvented room heater is installed in a bedroom and such unvented room heater is equipped as specified in section 621.6, has an input rating not greater than 10,000 BTU/h (2.93 kW), and a carbon monoxide detector, meeting the requirements of section R315 of the 2018 International Residential Code, is installed in the same room as the appliance. The bedroom shall meet the required volume criteria of section 304.5. 5. The appliance is installed in a room or space that opens only into a bedroom or bathroom, and such room or space is used for no other purpose and is provided with a solid weather-stripped door equipped with an approved self-closing device. All combustion air shall be taken directly from the outdoors in accordance with section 304.6.
(Code 2018, § 5-705)
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.