Sec. 5-2404. - Requirements.
Each temporary shelter unit shall meet the following: (a) Structure size. The habitable floor area shall be a minimum of 60 square feet with a minimum width of seven feet. (b) Doors. Egress doors shall be a minimum of 80 inches in height, 32 inches in width, and shall be equipped with a keyed doorknob lock to provide security for the occupant. (c) Windows. There shall be a minimum of two windows with the minimum openable space of eight inches in height by 16 inches in width. The windows shall be located on opposite walls to permit natural cross ventilation. (d) Emergency egress. A second egress is required, shall be located on the wall opposite the door, shall be a minimum of 22 inches in height and 36 inches in width, and shall be easily openable without a key or special knowledge. (e) Foundation. The temporary shelter unit shall be located on a level surface and properly secured to the ground by a method that is submitted and approved by the code official prior to occupancy. (f) Ground snow load and wind design. The roof snow load of the temporary shelter unit shall be 20 pounds per square foot. The temporary shelter unit shall be designed and constructed to withstand wind speed of 110 miles per hour. (g) Spacing. There shall be a minimum of ten-feet separation between each temporary shelter unit, measured from any exterior wall of all structures located on the premises. (h) Ceiling height. The minimum ceiling height shall be 84 inches. (i) Smoke alarms and carbon monoxide alarms. Each temporary shelter unit shall be equipped with a working smoke alarm and a working carbon monoxide alarm. Combination smoke and carbon monoxide alarms shall be permitted to be used in lieu of smoke alarms. Such alarms shall receive their primary power from the structure wiring and when power is interrupted, shall receive power from a battery. (j) Fire extinguishers. Each temporary shelter unit shall be equipped with one portable fire extinguisher having a minimum rating of 1-A:10-B:C. Such fire extinguisher shall be serviced annually by qualified service personnel, who shall possess a valid certificate issued by an approved governmental agency or other approved organization for the type of the work performed.
(Ord. No. 10058, § 1(5-2204), 7-16-2024)
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.