For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15-194 — Installation of the facilities

Code of Ordinances of the City of Manhattan, Kansas (Codified through Ordinance No. 7838, enacted September 15, 2026. (Supp. No. 68)) · Manhattan Code of Ordinances § 15-194

Corpus is an independent public-information project, not the official City of Manhattan website. Stable reference: corpuslaw.us/code/f5f717a7-d69b-4e01-b7df-6e8f82b1158f

Sec. 15-194. - Installation of the facilities.

(a) Pursuant to the grants provided herein, IdeaTek shall have the right to construct, maintain, and operate the facilities along, across, upon, and under the ROW. Nothing in this contract franchise ordinance shall be interpreted as granting IdeaTek the authority to construct, maintain or operate any facility or related appurtenance on property owned by the city outside of the ROW. (b) IdeaTek shall construct and maintain the facilities in a skillful and workmanlike manner that does not obstruct or hinder the usual travel or public safety on such ROW, and that does not obstruct or interfere with the legal use of the ROW by other utilities. IdeaTek shall be solely responsible for communicating with Kansas One-Call, or for taking other necessary measures to determine the location of public improvements or other facilities located in the ROW. IdeaTek shall install facilities in accordance with traffic control plans for temporary construction work that are approved by the city, which approval shall not unreasonably be withheld, conditioned or delayed. IdeaTek shall coordinate the placement of its facilities in the ROW in a manner that minimizes adverse impact on public improvements, as reasonably determined by the city engineer. (c) IdeaTek shall be the city's point of contact and all communications shall be through IdeaTek. IdeaTek shall at all times maintain with the city a local point of contact who shall be available at all times to act on behalf of IdeaTek in the event of an emergency. IdeaTek shall provide the city with the local contact's name, address, telephone number, fax number and e-mail address. (d) Notwithstanding any other ordinance or resolution adopted by the city, IdeaTek shall follow the following process: (1) IdeaTek shall submit to the city its plans and specifications for the installation of the facilities. Approval of plans and specifications and the issuance of any permits or approvals by the city shall not release IdeaTek from the responsibility for, or the correction of, any errors, omissions, or other mistakes that may be contained in the plans, specifications, or city permits or approvals. IdeaTek shall immediately notify the city and other relevant parties if IdeaTek discovers errors, omissions, or mistakes, and IdeaTek shall obtain any correct city approval, if necessary. (2) The city shall approve plans and specifications that comply with the requirements of this article. The city must respond to the submission of such plans and specifications within 15 working days from the date of submission of a complete application with the DAS facility permit and license fee. The location, aesthetic requirements, depth of the fiber underground, and any other requirements shall be approved by the city in writing prior to the instillation of any facilities at a specific location, and such approval shall not be unreasonably withheld, conditioned or delayed. The city shall have the authority to prohibit the use or occupation of a specific portion of the ROW by IdeaTek due to a reasonable public interest necessitated by public health, safety and welfare, so long as the authority is exercised in a competitively neutral manner and is not unreasonable or discriminatory. A reasonable public interest shall include the following: a. The prohibition is based upon a recommendation by the city engineer, is related to public health, safety, and welfare and is nondiscriminatory among providers, including incumbent providers; b. IdeaTek has rejected a reasonable, competitively neutral and nondiscriminatory justification offered by the city for requiring an alternate method or alternate route that will result in neither unreasonable additional installation expense nor a diminution of service quality; c. The city reasonably determines, after affording IdeaTek reasonable notice and an opportunity to be heard, that a denial is necessary to protect the public health and safety and is imposed on a competitively neutral and nondiscriminatory basis; or d. The specific portion of the ROW for which IdeaTek seeks use and occupancy is environmentally sensitive as defined by state or federal law or lies within a previously designated (as of the date of submission of the DAS facility permit application) historic district as defined by local, state or federal law. (e) IdeaTek shall cooperate with the city and follow all legally binding city policies and state and local ordinances with respect to aesthetics. (f) In addition to the approvals required by this section, IdeaTek must obtain and is responsible for any necessary permit, license, certification, grant, registration, and any other authorization or approval required by the city (collectively, the "permits and approvals") relating to the installation, maintenance, and repair of the facilities or network and for the use and occupancy of the ROW, including but not limited to all permits and approvals required under a city ROW ordinance or zoning regulation and that are not inconsistent with state and federal laws regarding the regulation of the public ROW. The city shall process each valid and administratively complete application for requested permits and approvals in accordance with the time requirements of applicable laws, and shall not unreasonably or unlawfully withhold or delay any permits and approvals. IdeaTek shall comply with any condition or requirement set forth in any permit and approval, if they comply with the laws. (g) Except as may otherwise be provided by this article, where reasonable and appropriate and where adequate public ROW exists, IdeaTek shall place all facilities underground, and/or replace all above-ground facilities with underground facilities, in conjunction with city capital improvement projects and/or at specific locations requested by the city, provided that such placement is practical, efficient, and economically feasible as determined by both parties. Above-ground pedestals, vaults, or other above-ground facilities, may be installed only if approved by the city where alternative underground facilities are not technically or financially feasible or where underground requirements are otherwise waived pursuant to this section, and shall generally be located behind the sidewalk where feasible and shall be screened from public view. The underground requirements of this subsection shall not apply to the maintenance and repair of existing facilities, as determined by the city engineer. (h) When IdeaTek is allowed to place DAS facilities above ground under this section, IdeaTek may attach its DAS facilities to an existing utility pole pursuant to a properly executed agreement with the pole owner provided. If IdeaTek locates on an existing utility pole owned by the city, IdeaTek shall be responsible for all costs to install and maintain a separate utility meter, and shall pay the electric costs related to its facilities on the city pole. IdeaTek agrees that in areas where there are existing poles, IdeaTek will work with the owner of that existing pole to collocate DAS facilities, but only when the pole owner is willing to allow such attachment and where such attachment is feasible from a safety, technical, and engineering (structural and radio frequency coverage) perspective. Any necessary replacement of any pole to accommodate the attachment shall be subject to the proper exercise of the city's police powers, and in no instance shall IdeaTek erect a new pole within an existing aerial pole line absent the city's prior authorization. IdeaTek may build new poles or other similar facilities required for the installation of the facilities which would comply with all encroachment and building permits, applicable city, state and federal specifications, and this article. IdeaTek hereby grants the city the right to use any new poles for city purposes, including, but not limited to, streetlights and other lighting, so long as such use does not interfere with IdeaTek's use of its facilities. IdeaTek shall reasonably cooperate with the city in the city's use of the new poles The city shall not be required to pay a fee to use IdeaTek's poles for a city purpose, except that IdeaTek may require the city to separately meter and pay for any city electrical use of IdeaTek's pole. Except for the installation of the lights and ancillary equipment on or in the new poles and/or as set forth in subsection (j) below, IdeaTek shall not be responsible for maintenance, repair, or replacement of city-owned lights, light bulbs and equipment or equipment owned by third parties authorized by the city on the new poles. (i) If IdeaTek's pole falls or is damaged such that there is an imminent threat of harm to persons or property, then the city may cause the pole to be removed to the side of the street or a location that city believes reasonably eliminates the risk of such imminent threat of harm to persons or property. IdeaTek shall, after written notice from the city that its pole has been damaged or removed, cause its pole to be removed, repaired or replaced within 30 days after the city's written notice. The cost to remove, repair or replace IdeaTek's pole, including the replacement city streetlight, bulb and ancillary equipment, shall be paid by IdeaTek; provided, however, that if IdeaTek's pole is damaged or destroyed by the city or a third party user that the city has given the right to use the pole, then the city and/or its third party user shall pay the cost to repair and/or replace the pole. To the extent that IdeaTek seeks reimbursement from a third party either directly or through applicable insurance, the city shall assign to IdeaTek any rights the city may have against such third party for such claim. (j) If there is an emergency necessitating response work or repair, IdeaTek may begin that repair or emergency response work or take any action required under the circumstances, provided that IdeaTek notifies the city promptly after beginning the work and timely thereafter meets any permit or other requirement had there not been such an emergency. (k) In granting this contract franchise ordinance, the city makes no express or implied representation or warranty regarding its rights to authorize the installation or construction of facilities on any particular segment of the ROW. The burden and responsibility for making all such determinations in advance of construction or installation shall be entirely upon IdeaTek. (l) IdeaTek shall take all reasonable measures necessary to maintain accurate as completed records in electronic format, of all facilities constructed, reconstructed, or relocated in the ROW. IdeaTek shall cooperate promptly and fully with the city and take all reasonable measures necessary to provide accurate and complete information regarding the nature and horizontal and vertical location of its facilities located within the ROW when requested by the city or its authorized agents for a public project. Such location and identification shall be at the sole expense of IdeaTek without expense to the city, its employees, agents, or authorized contractors. (m) IdeaTek may trim trees overhanging the ROW that may come into contact with IdeaTek facilities with the prior approval of the city's forester.

(Ord. No. 7103, § 5, 11-4-14)

Ask a question about Manhattan law

Corpus searches the Manhattan sections it holds and shows the ones that match, with their citations. Free, no sign-in.