For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 32-175 — Maintenance of grease interceptors and devices; best management practices; pumping and minimum pumping frequency; inspection; maintenance log

Code of Ordinances of the City of Manhattan, Kansas (Codified through Ordinance No. 7838, enacted September 15, 2026. (Supp. No. 68)) · Manhattan Code of Ordinances § 32-175

Corpus is an independent public-information project, not the official City of Manhattan website. Stable reference: corpuslaw.us/code/278e85aa-5294-4a2f-a5c3-a2c9a07da76d

Sec. 32-175. - Maintenance of grease interceptors and devices; best management practices; pumping and minimum pumping frequency; inspection; maintenance log.

(a) Illegal discharge. It shall be unlawful for the permit holder to discharge grease-laden waste into the sanitary sewer collection system without using a functional grease interceptor. It shall be unlawful for the permit holder to direct or allow any person to discharge grease-laden waste into the sanitary sewer collection system without using a functional grease interceptor. (b) Pumping. All grease interceptors shall be maintained by the user at the user's expense. Maintenance shall include the complete removal of all contents, including floating materials, wastewater, bottom sludge, and solids by a registered service provider pursuant to section 32-177. Decanting or discharging of removed waste back into the grease interceptor from which the waste was removed or any other grease interceptor, for the purpose of reducing the volume to be disposed, is prohibited. (c) Minimum pumping frequency. Grease interceptors must be completely pumped out a minimum of once every 90 days or whenever the combined depth of floating grease and settled solids reaches 50 percent of the total liquid volume of the grease interceptor. The director may require specific pumping frequencies for FSE based on evidence of carryover of grease-laden waste into the sanitary sewer collection system. (d) Best management practices. The director shall adopt best management practices to ensure the continual and effective operation of grease interceptors. The permit holder shall comply with, and cause the permit holder's employees, agents and other representatives to comply with, the best management practices adopted by the director. (e) Spills. If grease-laden waste spills onto the public right-of-way, parking area, driveway, or other location that may cause run-off into the stormwater management system, the spill shall be immediately cleaned up in a manner that complies with the best management practices adopted by the director. The permit holder shall notify the director that such spill occurred by the next business day. If the permit holder fails to clean the spill to the city's satisfaction, then the spill constitutes, and shall be treated as, a nuisance pursuant to chapter 21 of this Code. (f) Inspection. The permit holder shall have all grease interceptors inspected by a registered service provider pursuant to section 32-177 on an annual basis. Such registered service provider may not be the permit holder or an employee of the permit holder. Grease interceptors must be empty at the time of the inspection. The results of the inspection shall be recorded on the maintenance log described in subsection (g) below and shall be reported on a separate inspection form produced by the city and submitted to the city within 30 days of the inspection date. An inspection report will only be considered valid for permit renewal if it has been completed within 60 days prior to the permit expiration date per section 32-173(c). If the inspector notes deficiencies in a grease interceptor, the permit holder shall make necessary repairs to ensure compliance within 30 days of the date of the inspection, unless an extension is approved by the director. The permit holder shall provide documentation of such repairs to the director and allow inspections thereof, within 15 days of the completion of the repairs. (g) Maintenance log. On a form furnished by the city, each permit holder shall maintain a true and accurate maintenance log for each grease interceptor which provides for entry of the following information: (1) The date of each pumping service; the name of the person performing the service and the name of the company with which the service provider is affiliated; the amount removed; the condition of the device; and the signature of a manager or authorized representative of the facility in which the grease interceptor is located; and (2) All of the information regarding the annual inspection required by subsection (f) above; the name of the person performing the inspection; and the name of the company with which the inspector is affiliated. The maintenance log shall be kept in a readily accessible location and made immediately available upon request by the city. Each permit holder shall submit a copy of the previous year's maintenance log when renewing their annual permit and shall maintain copies of logs for three years. If a maintenance log is lost and cannot be submitted, the permit holder shall have an opportunity to verify all of the information required by the maintenance log in a manner acceptable to the city, and any failure to do so within ten days following the city's request shall be unlawful and a violation of this division.

(Ord. No. 7319, § 1, 10-17-17; Ord. No. 7828, § 2, 6-2-26)

Ask a question about Manhattan law

Corpus searches the Manhattan sections it holds and shows the ones that match, with their citations. Free, no sign-in.