§ 8-48 — Amendments

Code of Ordinances of the City of Manhattan, Kansas (Codified through Ordinance No. 7838, enacted September 15, 2026. (Supp. No. 68)) · Manhattan Code of Ordinances § 8-48

Corpus is an independent public-information project, not the official City of Manhattan website. Stable reference: corpuslaw.us/code/4aec96a9-0c25-43b1-aac3-ebbe514ff020

Sec. 8-48. - Amendments.

The National Electrical Code, adopted by section 8-47 is hereby changed, altered, modified and otherwise amended as follows: (1) Article 210.52(C)(2) of the National Electrical Code is hereby changed to read as follows: Article 210.52(C)(2) Island and Peninsular Countertops and Work Surfaces. (a) At least one receptacle outlet shall be provided for the first 9 square feet (0.84 m2), or fraction thereof, of the countertop or work surface. A second separate and remotely located receptacle outlet shall be provided if the island or peninsula counter top or work surface is greater than 9 square feet. (b) At least one receptacle outlet shall be located within 600 mm (2 ft) of the outer end of a peninsular countertop or work surface. Additional required receptacle outlets shall be permitted to be located as determined by the installer, designer, or building owner. The location of the receptacle outlets shall be in accordance with 210.52(C)(3). A peninsular countertop shall be measured from the connected perpendicular wall. (2) Article 300.5(C) of the National Electrical Code is hereby changed to read as follows: Article 300.5(C) Underground Cables Under Buildings. Underground cable and conductors installed under a building shall be in a raceway. (3) Article 314.27(C) of the National Electrical Code is hereby changed to read as follows: Article 314.27(C) Boxes at Ceiling-Suspended (Paddle) Fan Outlets. Outlet boxes or outlet box systems used as the sole support of a ceiling-suspended (paddle) fan shall be listed, shall be marked by their manufacturer as suitable for this purpose, and shall not support ceiling-suspended (paddle) fans that weigh more than 32 kg (70 lb). For outlet boxes or outlet box systems designed to support ceiling-suspended (paddle) fans that weigh more than 16 kg (35 lb), the required marking shall include the maximum weight to be supported. Outlet boxes mounted in the ceilings of habitable rooms of dwelling occupancies in a location acceptable for the installation of a ceiling-suspended (paddle) fan shall comply with one of the following: (1) Listed for the sole support of ceiling-suspended (paddle) fans (2) An outlet box complying with the applicable requirements of 314.27 and providing access to structural framing capable of supporting of a ceiling-suspended (paddle) fan bracket or equivalent Exception: Outlet boxes within 3 feet of a wall or provided for a smoke or carbon monoxide alarms. (4) Article 334.10 of the National Electrical Code is hereby changed to read as follows: Article 334.10 Uses Permitted. Type NM, Type NMC, and Type NMS cables shall be permitted to be used in the following: (1) One- and two-family dwellings. (2) Multi-family dwellings permitted to be of Type III, IV and V construction. A) Type NM. Type NM cable shall be permitted as follows: (1) For both exposed and concealed work in normally dry locations except as prohibited in section 334.10(3). (2) To be installed or fished in air voids in masonry block or tile walls. B) Type NMC. Type NMC cable shall be permitted as follows: (1) For both exposed or concealed work in dry, moist, damp or corrosive locations, except as prohibited by 334.10(3). (2) In outside and inside walls of masonry block or tile. (3) In a shallow chase in masonry, concrete or adobe protected against nails or screws by a steel plate at least 1/16 inch thick and covered with plaster, adobe or similar finish. C) Type NMS. Type NMS cable shall be permitted as follows: (1) For both exposed and concealed work in normally dry locations except as prohibited by 334.10(3). (2) To be installed or fished in air voids in masonry block or tile walls. (5) Article 334.12(A) of the National Electrical Code is hereby changed to read as follows: Article 334.12(A) Types NM, NMC, and NMS. Types NM, NMC and NMS cables shall not be permitted as follows: (1) In any structure not specifically permitted in 334.10 (1) and (2) (2) As service entrance cable. (3) In hoistways or on elevators or escalators. (4) Embedded in poured concrete or aggregate. (6) Article 334.12(B) of the National Electrical Code is hereby changed to read as follows: Article 334.12(B) Types NM and NMS. Type NM and NMS cables shall not be used under the following conditions or in the following locations: (1) Where exposed to corrosive fumes or vapors. (2) Where embedded in masonry, concrete, adobe, fill or plaster. (3) In a shallow chase in masonry, concrete, or adobe and covered with plaster, adobe or similar finish. (4) Where exposed or subject to excessive moisture or dampness. (7) Articles 406.4(D)(4), 406.4(D)(5), and 406.4(D)(6) of the National Electrical Code are hereby deleted. (8) Article 406.9(B)(1) of the National Electrical code is hereby changed to read as follows: Article 406.9(B)(1) 15 and 20 Ampere Receptacles in a Wet Location. 15 and 20 ampere, 125- and 250-volt receptacles installed in a wet location shall have an enclosure for the receptacle that is weatherproof when the receptacle is covered (attachment plug cap not inserted and receptacle covers closed). All 15 and 20 ampere, 125- and 250-volt non locking type receptacles shall be listed weather resistant type.

(Ord. No. 3826, § 2, 12-2-80; Ord. No. 4136, § 2, 6-5-84; Ord. No. 4636, § 1, 3-20-90; Ord. No. 4816, § 1, 9-21-93; Ord. No. 5013, § 1, 1-7-97; Ord. No. 6191, § 1, 2-6-01; Ord. No. 6416, § 1, 7-6-04; Ord. No. 6643, § 1, 7-17-07; Ord. No. 6849, § 2, 11-16-10; Ord. No. 7026, § 2, 8-6-13; Ord. No. 7231, § 2, 6-21-16; Ord. No. 7432, § 2, 6-18-19; Ord. No. 7611, § 2, 10-18-22)

Ask a question about Manhattan law

Corpus searches the Manhattan sections it holds and shows the ones that match, with their citations. Free, no sign-in.