For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.110.R506.4

Code of the City of Overland Park, Kansas · Overland Park Municipal Code, tit. 16, art. 16.110, § 16.110.R506.4

Corpus is an independent public-information project, not the official City of Overland Park website. Stable reference: corpuslaw.us/code/f4bb56a0-4a96-4b22-aeec-6a9c9b34757a

16.110.R506.4

Section R506.4 of the International Residential Code for One- and Two-Family Dwellings is hereby added to read as follows: R506.4 Basement Floor Slab Isolation. Basement floor slabs shall be isolated from column pads, interior columns and interior bearing walls to facilitate differential movement. Nonbearing walls supported on basement floor slabs shall be provided with a minimum one inch (1”) expansion joint to facilitate differential movement between the floor slab and the floor framing above. Isolation and/or an expansion joint is not required within six inches (6”) of the exterior walls. (History:Ord. BC-3286 §66, 2020; Ord. BC-2936 §48, 2012; BC-2635 §67, 2007) Effective on: 1/1/1901

Ask a question about Overland Park law

Corpus searches the Overland Park sections it holds and shows the ones that match, with their citations. Free, no sign-in.