For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.305.303

Code of the City of Overland Park, Kansas · Overland Park Municipal Code, tit. 16, art. 16.305, § 16.305.303

Corpus is an independent public-information project, not the official City of Overland Park website. Stable reference: corpuslaw.us/code/f114493e-592b-4e40-9d46-d3207932240f

16.305.303

Section 303 of the International Existing Building Code is hereby amended to read as follows: 303.1 General This section applies to the design and construction of storm shelters for the purpose of providing protection during tornadoes, hurricanes and other severe windstorms. 303.1.1 Construction. Storm shelters shall be constructed in accordance with Section 423 of the International Building Code and ICC 500 and shall be designated as hurricane shelters, tornado shelters or combined hurricane and tornado shelters. Exception: Storm shelters added to critical emergency operations facilities or Group E occupancies are not required to comply with the travel distance in Section 423.4.2 or 423.5.2 of the International Building Code. 303.2 Addition to a Group E occupancy. Where an addition is added to an existing Group E occupancy, and the addition includes a gymnasium, located in an area where the shelter design wind speed for tornadoes is 250 mph (402.3 km/h) in accordance with Figure 304.2(1) of ICC 500 and the occupant load in the addition is 50 or more, the addition shall have a storm shelter constructed in accordance with ICC 500. Exceptions: (1) 1. Group E day care facilities. (2) 2. Group E occupancies accessory to places of religious worship. (3) 3. Additions meeting the requirements for shelter design in ICC 500. 303.2.1 Design occupant capacity. The required design occupant capacity of the storm shelter shall include all buildings on the site, and shall be the total occupant load of the classrooms, vocational rooms and offices in the Group E occupancy. The code official may accept the student and staff projections that the school district has tabulated and presented to the School Board. Exception: Where approved by the code official, the required design occupant capacity of the shelter shall be permitted to be reduced by the design occupant capacity of any existing storm shelters on the site. 303.2.2 Water closets and lavatories. Water closets and lavatories provided for additions to a Group E occupancy and required by ICC 500 shall be provided within the shelter or within the building served by the shelter. 303.3 Occupancy classification. The occupancy classification for storm shelters shall be determined in accordance with Section 423.3 of the International Building Code. (History: Ord. No. BC-3499, §56, 2026; Ord. No. BC-3286 §43, 2020) Effective on: 1/1/1901

Ask a question about Overland Park law

Corpus searches the Overland Park sections it holds and shows the ones that match, with their citations. Free, no sign-in.