For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.330.403.1

Code of the City of Overland Park, Kansas · Overland Park Municipal Code, tit. 16, art. 16.330, § 16.330.403.1

Corpus is an independent public-information project, not the official City of Overland Park website. Stable reference: corpuslaw.us/code/3aa65a64-a1d9-420b-9350-2158202a6f9d

16.330.403.1

Section 403.1 of the International Plumbing Code is hereby amended to read as follows1: 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number as shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Exception to Table 403.1: A service sink is not required in business or mercantile occupancies with a total of 2500 square feet or less of gross floor area and where the nature of the business does not include services or processes requiring frequent mopping of floor surfaces. Food service or merchants, beauty parlors, barber shops and veterinary clinics are examples of businesses that require a service sink. 403.1.1 Fixture calculations. To determine the occupant load of each sex, the total occupant load shall be divided in half. To determine the required number of fixtures, the fixture ratio or ratios for each fixture type shall be applied to the occupant load of each sex in accordance with Table 403.1. Fractional numbers resulting from applying the fixture ratios of table 403.1 shall be rounded up to the next whole number. For calculations involving multiple occupancies, such fractional numbers for each occupancy shall first be summed and then rounded up to the next whole number. Exceptions: (1) 1. The total occupant load shall not be required to be divided in half where approved statistical data indicates a distribution of the sexes of other than 50 percent of each sex. (2) 2. Where multiple-user facilities are designed to serve all genders, the minimum fixture count shall be calculated 100 percent, based on total occupant load. In such multiple-user facilities, each fixture type shall be in accordance with ICC A117.1. 403.1.2 Fixtures in single-user toilet facilities and bathing rooms. The plumbing fixtures located in single-user toilet facilities and single-user bathing rooms, including family or assisted-use toilet facilities and bathing rooms, shall contribute toward the total number of required plumbing fixtures for a building or tenant space. The number of fixtures in single-user toilet facilities, single-user bathing rooms and family or assisted-use toilet facilities shall be deducted proportionally from the required gender ratios of Table 403.1. Single-user toilet facilities and bathing rooms, and family or assisted-use toilet facilities and bathing rooms shall be identified as being available for use by all persons regardless of their sex. 403.1.3 Lavatory distribution. Where two or more toilet facilities are provided for each sex, the required number of lavatories shall be distributed proportionately to the required number of male and female designated water closets. 1Note: Only text is being amended. Table 403.1 shall remain as published in the International Plumbing Code. (History: Ord. No. BC-3499, §122, 2026; Ord. No. BC-3286 §147, 2020; Ord. No. BC-3286 §147, 2020; Ord. No. BC-2936 §113, 2012; Ord. No. BC-2635 §142, 2007) Effective on: 1/1/1901

Ask a question about Overland Park law

Corpus searches the Overland Park sections it holds and shows the ones that match, with their citations. Free, no sign-in.