For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 403 — General Urban Frontage

Code of the City of Overland Park, Kansas · Overland Park Downtown Form-Based Code, pt. 4, § 403

Corpus is an independent public-information project, not the official City of Overland Park website. Stable reference: corpuslaw.us/code/db858628-32e7-4b11-ae73-a6719cb4302d

DFD 403 . General Urban Frontage

This is the basic urban street frontage, once common across the United States. The uses range from commercial to residential, retail to municipal- and combinations of all of the above. The primary form is that of a multi-story building placed directly at the sidewalk with windows across the facade. There could be several buildings lined up shoulder to shoulder, filling out a block, or on smaller blocks, a single building might fill the block face. ILLUSTRATIONS AND INTENT Note: These are provided as illustrations of intent. The depictions under Illustrations and Intent are advisory only and do not have the power of law. Refer to the following standards for the specific prescriptions and restrictions of the Building Envelope Standard. DFD 403 Illustrations and Intent [image omitted; see the official code] [image omitted; see the official code] | [image omitted; see the official code] [image omitted; see the official code] | DFD 403 Standards [image omitted; see the official code] (1) (1) (2) (2) (3) (4) (1) (2) (1) (2) (1) (2) HEIGHT Building Height The building shall be at least 2 Stories in height, but no greater than 5 Stories and 79 feet in height, unless otherwise designated on the Regulating Plan. Ground Story Height: Commerce Uses 1. The average Ground Story finished floor elevation within 30 feet of the RBL shall be a. not lower than the fronting exterior sidewalk elevation b. not higher than an average finished floor elevation of 18 inches above the sidewalk. 2. See Commerce Frontage Special Conditions box below Use. 3. The Ground Story shall have at least 15 feet of clear interior height (floor to ceiling) contiguous to the RBL frontage for a minimum depth of 20 feet. 4. The maximum Ground Story height is 22 feet, measured from the sidewalk to the second Story floor. Ground Story Height: Residential Units 1. The average finished floor elevation shall be no less than 18 inches above the exterior sidewalk elevation at the RBL. 2. The Ground Story shall have an interior clear height (floor to ceiling) of at least 9 feet and a maximum sidewalk to second Story floor height of 22 feet. Upper Story Height 1. The maximum clear height (floor to ceiling) for Stories other than the Ground Story is 12 feet. 2. At least 80% of each upper Story shall have an interior clear height (floor to ceiling) of at least 9 feet. Street Wall Height A Street Wall not less than 3 feet in height or greater than 8 feet in height shall be required along any RBL frontage that is not otherwise occupied by a building on the lot. | SITING Façade 1. On each lot the building Facade shall be built-to the Required Building Line for at least 75% of the RBL length. 2. Within 8 feet of the Block Corner, the Ground Story Facade may be pulled away to form a corner entry. Buildable Area A contiguous Private Open Area equal to at least 15% of the total Buildable Area shall be preserved on every lot. Up to 33% of the required open area may be satisfied through the Balconies of individual units. Such contiguous Private Open Area maybe located anywhere behind the Parking Setback line and not including any side or rear setbacks, at or above grade. Garage and Parking Openings in any RBL for parking garage entries shall have a maximum clear height no greater than 16 feet and a clear width no greater than 24 feet. DFD 403 Standards [image omitted; see the official code] (1) (2) (3) (4) (1) (1) (2) (2) (3) (1) (2) (3) (1) (2) (3) (4) Commerce Frontage Special Conditions General Storefront Frontages Where designated on the Regulating Plan as General Storefront these frontages shall use this General Urban BES standard, excepting that the Ground Story configuration shall be for commerce - that of a Shopfront. (See DFD 606.D.3 Shopfront Windows for specific requirements.) Steep Slope Exceptions: Subject to the Director’s approval, for approved grocery operations, where the average slope across a Street Frontage for a given Block face is greater than or equal to 5%, the Ground Story finished floor elevation requirement may be measured across a frontage width increment of 120 feet to a maximum 27 inches (average) above the fronting sidewalk. Effective on: 1/1/1901

Ask a question about Overland Park law

Corpus searches the Overland Park sections it holds and shows the ones that match, with their citations. Free, no sign-in.