§ 30-60 — Duties of alarm installation companies
Salina Code, City of Salina, Kansas (Codified through Ordinance No. 26-11299 adopted August 24, 2026. (Supp. No. 19)) · Salina Municipal Code § 30-60
Corpus is an independent public-information project, not the official City of Salina website. Stable reference: corpuslaw.us/code/0222a2b4-dd74-4818-af90-d89542540d7c
Sec. 30-60. - Duties of alarm installation companies.
(a) An alarm installation company that installs or modifies an alarm system on premises located within the city shall notify the alarm administrator within ten (10) days that the alarm system has been installed or modified, and shall send the alarm administrator the required information pertaining to the installation or modification. In the case of self-installed alarm systems that are to be monitored by a monitoring company, the monitoring company shall have the same duties imposed on an alarm installation company under this section. An alarm installation company shall be assessed a fee for each failure to notify the alarm administrator within ten (10) days after the installation or modification of an alarm system. (b) Upon the installation or activation of an alarm system, the alarm installation company shall distribute to the alarm user information and instructions related to: (1) The applicable law relating to false alarms, including the alarm registration requirement and the potential for fees and suspension of an alarm registration; (2) Preventing false alarms; and (3) Operating the alarm system and ensuring that the alarm user of an alarm system equipped with a robbery or panic alarm has been provided adequate training as to the proper use of the alarm system's operation and function. (c) After the effective date of this article, alarm installation companies shall not program alarm systems so that they are capable of sending one plus duress alarms. Monitoring companies may continue to report one plus duress alarms received from alarm systems programmed with one plus duress alarms installed prior to the effective date of this article. (d) After the effective date of this article, alarm installation companies shall not install single action devices for the activation of robbery or panic alarms. New devices shall require two actions or an activation time delay to provide more positive assurance that the user intends to activate the device. (e) Ninety (90) days after the effective date of this article, alarm installation companies shall, on new installations, use only alarm control panels that meet SIA Control Panel Standard CP-01. (f) An alarm installation company shall not use an automatic voice dialer for any alarm system. (g) All alarm systems shall be installed and supplied with an uninterrupted power supply in such a manner that the failure or interruption of the normal electric utility service will not activate the alarm system. (h) All audible alarm systems shall include a device which will limit the duration of the audible alarm to a period of not more than ten (10) minutes per activation.
(Ord. 15-10778, § 1, 7-6-15)
Ask a question about Salina law
Corpus searches the Salina sections it holds and shows the ones that match, with their citations. Free, no sign-in.