Sec. 31-103.2. - Unsafe conditions.

The following conditions shall be determined as unsafe and shall be repaired or replaced to comply with the Salina Code as required for existing buildings: (1) The nominal strength of any structural member is exceeded by nominal loads, the load effects or the required strength; (2) The anchorage of the floor or roof to walls or columns, and of walls and columns to foundations is not capable of resisting all nominal loads or load effects; (3) Structures or components thereof that have reached their limit state; (4) Siding and masonry joints including joints between the building envelope and the perimeter of windows, doors and skylights are not maintained such that the structure is reasonably weather resistant or water tight; (5) Structural members that have evidence of deterioration or that are not capable of safely supporting all nominal loads and load effects; (6) Foundation systems that are not firmly supported by footings which are reasonably plumb and free from open cracks and breaks, are not anchored and maintained such that they are capable of supporting all nominal loads and resisting all load effects; (7) Exterior walls that are not anchored to supporting and supported elements or are not plumb and free of holes, cracks or breaks and loose or rotting materials, or are anchored and maintained such that they are capable of supporting all nominal loads and resisting all load effects; (8) Roofing or roofing components that have defects that admit rain, roof surfaces with inadequate drainage, or any portion of the roof framing that is not in good working order with signs of deterioration, fatigue or without proper anchorage and incapable of supporting all nominal loads and resisting all load effects; (9) Flooring and flooring components with defects that affect serviceability or are not anchored or maintained such that they are capable of supporting all nominal loads and resisting all load effects; (10) Veneer, cornices, belt courses, corbels, trim, wall facings and similar decorative features which present an imminent hazard by not being anchored or maintained such that they are capable of supporting all nominal loads and resisting all load effects; (11) Overhang extensions or projections including, but not limited to, trash chutes, canopies, marquees, signs, awnings, fire escapes, standpipes and exhaust ducts not anchored or maintained such they are capable of supporting all nominal loads and resisting all load effects; (12) Exterior stairs, decks, porches, balconies and all similar appurtenances attached thereto, including guards and handrails, are not structurally sound, or not anchored and maintained such that they are capable of supporting all nominal loads and resisting all load effects; or (13) Chimneys, cooling towers, smokestacks and similar appurtenances not structurally sound or not anchored or maintained such that they are capable of supporting all nominal loads and resisting all load effects. Exceptions: a. When substantiated otherwise by an approved method or by a properly licensed design professional. b. Demolition of unsafe conditions shall be permitted when approved by the code official.

(Ord. 13-10693, § 1, 4-15-13)

Ask a question about Salina law

Corpus searches the Salina sections it holds and shows the ones that match, with their citations. Free, no sign-in.