§ 11.32.070 — Provisions for Flood Hazard Reduction

Municipal Code of the City of Shawnee, Kansas (Codified through Ordinance No. 3558, adopted August 10, 2026. (Supp. No. 9, Update 2)) · Shawnee Municipal Code § 11.32.070

Corpus is an independent public-information project, not the official City of Shawnee website. Stable reference: corpuslaw.us/code/df1a4aea-c568-4f5e-aea6-7a26c69a94b3

11.32.070 - Provisions for Flood Hazard Reduction.

A. General Standards: 1. No permit for Floodplain Development shall be granted for new construction, Substantial Improvements, and other improvements, including the placement of Manufactured Homes, within any numbered or unnumbered A zones, AE, AO, and AH zones, unless the conditions of this Section are satisfied. 2. All areas identified as unnumbered A zones on the FIRM are subject to inundation of the one percent (1%) chance Flood (100-year Flood); however, the Base Flood elevation is not provided. Development within unnumbered A zones is subject to all provisions of this Chapter. If Flood Insurance Study data is not available, the Floodplain Administrator shall obtain, review, and reasonably utilize any base Flood elevation or Floodway data currently available from Federal, State, or other sources. Conclusive engineering data which establishes the Base Flood Elevations and Floodway shall then be submitted by the Professional Engineer to the City for review. 3. Until a Floodway is designated, no new construction, substantial improvements, or other Development, including fill, shall be permitted within any unnumbered or numbered A zones, or AE zones on the FIRM, unless it is demonstrated that the cumulative effect of the proposed Development, when combined with all other existing and anticipated Development, will not increase the water surface elevation of the Base Flood more than one (1) foot at any point. Additional conditions are established in Section 11.32.060A.4. 4. Grading changes within the Flood Fringe must not cause an increase in the Base Flood Elevation unless the Floodplain Administrator has expressly issued a written waiver of this requirements and acknowledges the rise. 5. All New Construction, subdivision proposals, Substantial-Improvements, prefabricated Structures, placement of Manufactured Homes, and other Developments shall require: a. Design or adequate anchorage to prevent flotation, collapse, or lateral movement of the Structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; b. Construction with materials resistant to Flood damage; c. Utilization of methods and practices that minimize Flood damages; d. All electrical, heating, ventilation, plumbing, air-conditioning equipment, and other service facilities be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of Flooding; e. New or replacement water supply systems and/or sanitary sewage systems be designed to minimize or eliminate infiltration of Flood waters into the systems and discharges from the systems into Flood waters, and on-site waste disposal systems be located so as to avoid impairment or contamination from them during Flooding; and f. Subdivision proposals and other proposed new Development, including Manufactured Home Parks or Subdivisions, located within Special Flood Hazard Areas are required to assure that: i. All such proposals are consistent with the need to minimize Flood damage; ii. All public utilities and facilities, such as sewer, gas, electrical, and water systems are located and constructed to minimize or eliminate Flood damage; iii. Adequate drainage is provided so as to reduce exposure to Flood hazards; iv. All proposals for Development include within such proposals Base Flood elevation data; v. New subdivision plats or rezonings which contain SFHAs, cannot create a new lot within the SFHA which would allow constructing a residential dwelling; and vi. New subdivision plats with only one (1) public street for access during any phase of platting, shall meet one (1) of the following: • The public street, including the street's intersection to the existing streets, shall be constructed outside of the SFHA; or • The depth of stormwater for public streets constructed in the SFHA shall meet the requirements of the Shawnee Design and Construction Manual, including the street's intersection to existing streets. • A secondary emergency access route is provided, as approved by the Fire Department. 6. Storage, Material, and Equipment. a. The storage or processing of materials within SFHAs that are in time of Flooding buoyant, flammable, explosive, or could be injurious to human, animal, or plant life is prohibited. b. Storage of other material or equipment may be allowed if not subject to major damage by Floods, if firmly anchored to prevent flotation or if readily removable from the area within the time available after a Flood warning. 7. Nonconforming Use. A Structure, or the use of a Structure or premises that was lawful before the passage or amendment of the Chapter, but which is not in conformity with the provisions of this Chapter, may be continued subject to the following conditions: a. If such Structure, use, or utility service is discontinued for six (6) consecutive months, any future use of the Building shall conform to this Chapter. b. If any nonconforming use or Structure is destroyed by any means, including Flood, it shall not be reconstructed if the cost is more than fifty percent (50%) of the pre-damaged Market Value of the Structure. This limitation does not include the cost of any alteration to comply with existing state or local health, sanitary, Building, safety codes, regulations or the cost of any alteration of a Structure listed on the National Register of Historic Places, the State Inventory of Historic Places, or local inventory of historic places upon determination. c. No such use or substantial improvement of that use shall be expanded, changed, enlarged or altered in any way, which increases its nonconformity. 8. Agricultural Structures. Structures used solely for agricultural purposes in connection with the production, harvesting, storage, drying, or raising of Agricultural Commodities, including the raising of livestock, may be constructed at-grade and wet-Floodproofed provided there is no human habitation or occupancy of the Structure; the Structure is of single-wall design; there is no permanent retail, wholesale, or manufacturing use included in the Structure; a variance has been granted from the Floodplain Management Requirements of this Chapter; and a Floodplain Development Permit has been issued. Any permit granted for an agricultural structure shall be decided individually based on a case-by-case analysis of the building's unique circumstances. In order to minimize flood damages during the 100-year flood and the threat to public health and safety, the following conditions shall be included for any permit issued for Agricultural Structures that are constructed at-grade and wet-floodproofed: a. All proposed Agricultural Structures shall demonstrate that no other alternate location outside of the SFHA exists for the agricultural structure. Residential structures, such as farmhouses, cannot be considered agricultural structures. b. Use of Agricultural Structures must be limited to agricultural purposes in any SFHA only as identified on the City's FIRM. c. For any new or substantially damaged Agricultural Structures, the exterior and interior building components and elements (i.e., foundation, wall framing, exterior and interior finishes, flooring, etc.) below the base flood elevation, must be built with flood-resistant materials in accordance with Section 11.32.060.A.5.b. d. The Agricultural Structures must be adequately anchored to prevent flotation, collapse, or lateral movement of the structures in accordance with Section 11.32.060.A.5.a. All of the building's structural components must be capable of resisting specific flood-related forces including hydrostatic, buoyancy, and hydrodynamic and debris impact forces. e. Any mechanical, electrical, or other utility equipment must be located one (1) foot above the base flood elevation or floodproofed so that they are contained within a watertight, floodproofed enclosure that is capable of resisting damage during flood conditions in accordance with Section 11.32.060.A.5.d. The elevation shall be certified by a licensed land surveyor or professional engineer. f. The Agricultural Structures must meet all National Flood Insurance Program (NFIP) opening requirements. The NFIP requires that enclosure or foundation walls, subject to the one-percent (1%) annual chance flood event, also referred to as the 100-year flood, contain openings that will permit the automatic entry and exit of flood waters in accordance with Section 11.32.060.B.1.c. g. No permits may be issued for Agricultural Structures within any designated Floodway. h. Major equipment, machinery, or other contents must be protected from any flood damage. i. No disaster relief assistance under any program administered by any Federal agency shall be paid for any repair or restoration costs of the Agricultural Structures. j. Wet-floodproofing construction techniques must be reviewed and approved by the City. The City may request approval by a registered Professional Engineer prior to the issuance of any Floodplain Development Permit for construction. 9. Accessory Structures. If granted a Variance per Section 11.32.080, Accessory Structures used solely for parking and limited storage purposes, not attached to any other Structure on the site, of limited investment value, and not larger than four hundred (400) square feet, may be constructed at-grade and wet-floodproofed provided there is no human habitation or occupancy of the Structure; the Structure is of single-wall design; a variance has been granted from the standard Floodplain management requirements of this Chapter; and a Floodplain Development Permit has been issued. In order to minimize flood damages during the 100-year flood and the threat to public health and safety, the following conditions shall be included for any permit issued for Accessory Structures that are constructed at-grade and wet-floodproofed: a. Use of the Accessory Structures must be solely for parking and limited storage purposes in any SFHA as identified on the City's FIRM. b. For any new or substantially damaged Accessory Structures, the exterior and interior building components and elements (i.e., foundation, wall framing, exterior and interior finishes, flooring, etc.) below the BFE, must be built with flood-resistant materials in accordance with Section 11.32.060.A.5.b. c. The Accessory Structures be adequately anchored to prevent flotation, collapse, or lateral movement of the structures in accordance with Section 11.32.060.A.5.a. All of the building's structural components must be capable of resisting specific flood-related forces including hydrostatic, buoyancy, and hydrodynamic and debris impact forces. d. Any mechanical, electrical, or other utility equipment must be located one (1) foot above the BFE or floodproofed so that they are contained within a watertight, floodproofed enclosure that is capable of resisting damage during flood conditions in accordance with Section 11.32.060.A.5.d. The elevation shall be certified by a licensed land surveyor or professional engineer. e. The Accessory Structures must meet all NFIP opening requirements. The NFIP requires that enclosure or foundation walls, subject to the one-percent (1%) annual chance flood event, also referred to as the 100-year flood, contain openings that will permit the automatic entry and exit of flood waters in accordance with Section 11.32.060.B.1.c. f. No permits may be issued for Accessory Structures within any designated Floodway. g. Major equipment, machinery, or other contents must be protected from any flood damage. h. No disaster relief assistance under any program administered by any Federal agency shall be paid for any repair or restoration costs of the Accessory Structures. i. Wet-floodproofing construction techniques must be reviewed and approved by the City. The City may request approval by a registered Professional Engineer prior to the issuance of any Floodplain Development Permit for construction. 10. Temporary Structures: Any variance granted for a Temporary Structure shall be decided individually based on a case-by-case analysis of the Building's unique circumstances. Variances granted shall meet the following conditions, as well as those criteria and conditions set forth in Section 11.32.080. 1. A Temporary Structure may be considered for location within the one-percent (1%) annual chance Flood event, also referred to as the 100-year Floodplain only when all of the following criteria are met: a. Use of the Temporary Structure is unique to the land to be developed and cannot be located outside of the Floodplain nor meet the NFIP design standards; b. Denial of the Temporary Structure permit will create an undue hardship on the property owner; c. The City has adopted up-to-date NFIP and Building regulations to direct placement and removal of the Temporary Structure; and d. The City has sufficient staff to monitor the placement, use, and removal of the Temporary Structure throughout the duration of the permit. 2. Once all of the above conditions are met, an application for a Temporary Structure permit must be made to the Governing Body. The Governing Body shall consider all applications for Temporary Structure permits for a Temporary Structure based on the following criteria: a. The placement of any Temporary Structure within the Special Flood Hazard Areas as shown on the City's adopted FEMA/NFIP map shall require an approved Temporary Structure permit. The Temporary Structure permit shall be valid for a period not to exceed one hundred eighty (180) days, with the exception of equipment and facilities used for the mining and extraction of sand and gravel in the Floodplain. b. Temporary Structure permit applications for a Temporary Structure to be located in Special Flood Hazard Areas shall conform to the standard public hearing process prior to any City action on the permit request. c. An emergency plan for the removal of the Temporary Structure that includes specific removal criteria and time frames from the agency or firm responsible for providing the manpower, equipment, and the relocation and disconnection of all utilities shall be required, as part of the Temporary Structure permit application, for the placement of any Temporary Structure. d. On or before the expiration of the end of the one hundred eighty-day Temporary Structure permit period, the Temporary Structure shall be removed from the site. All utilities, including water, sewer, communication, and electrical services, shall be disconnected. e. To ensure the continuous mobility of the Temporary Structure for the duration of the permit, the Temporary Structure shall retain its wheels and tires, licenses, and towing appurtenance on the Structures at all times. f. Under emergency Flooding conditions, the Temporary Structure shall be removed immediately or as directed by the City and as specified in the emergency removal plan. g. Location of any Temporary Structure within the regulatory Floodway requires the provision of a "no-rise" certificate by a registered professional engineer, licensed by the State of Kansas. h. Violation of, or non-compliance with, any of the stated conditions of the Temporary Structure permit during the term thereof, shall make the permit subject to revocation by Floodplain Administrator. Issuance of permit revocation notice shall be made to the landowner, the occupant of the land, and to the general public. i. Any deviation from the approved site plan shall be deemed a violation of the Temporary Structure permit approval and the uses allowed shall automatically be revoked. The subsequent use of the land shall be deemed a violation of this Chapter and shall be illegal, nonconforming uses and shall be summarily removed and abated. j. If the Temporary Structure is to be returned to its previously occupied site, the process for issuing a Temporary Structure permit must be repeated in full. Any subsequent permit shall be valid for a period not to exceed one hundred eighty (180) days. 11. Critical Facilities. All new construction and substantial improvements of critical and essential nonresidential facilities including, but not limited to: a. Police stations, fire stations, vehicle and equipment maintenance and storage facilities, emergency operations centers, and other governmental Buildings that are needed for flood response activities before, during, and after a flood; b. Hospitals, nursing homes, orphanages, penal institutions, and other such facilities likely to contain occupants who are confined or otherwise not sufficiently mobile to avoid death or injury during a flood; c. Schools and other places of enclosed public assembly; d. Domestic water and sanitary sewage treatment facilities, domestic water and sanitary sewage pump stations serving areas not completely in a two tenths (0.2) percent annual chance flood hazard area, also referred to as the 500-year Flood, communication centers, and other public and private utility facilities that are vital to maintaining or restoring normal services to flooded areas before, during, and after a flood; and, e. Emergency aviation facilities; shall comply with all other provisions of this Chapter and the following requirements: f. All critical and essential facilities, together with attendant utility and sanitary facilities, shall either be elevated at least one (1) foot above the .2 percent annual chance flood event, also referred to as the 500-year flood or two (2) feet higher than the Base Flood Elevation, whichever is higher or be floodproofed; g. To be considered Floodproofed, a critical or essential facility must be watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. A registered professional engineer or architect, licensed by the State of Kansas, shall certify that the standards of this subparagraph are satisfied. Such certification shall be provided to the Floodplain Administrator as set forth in this Chapter. h. No critical or essential facility shall be constructed in any designated floodway, except sanitary sewer and water supply facilities. i. Stormwater quality treatment or detention facilities are not a critical or essential facility j. All critical facilities shall have access routes that are above the 500-year flood 12. Hazardous Materials. All hazardous material storage and handling sites shall be located out of the SFHA. 13. Cumulative Improvement. A Structure may be improved (remodeled or enlarged) without conforming to current requirements for elevation so long as the cumulative value of all work done within the last five (5) calendar years does not exceed fifty percent (50%) of the Structure's current Market Value. If the cumulative value of the improvement exceeds fifty percent (50%) of the Structure's current Market Value, the Structure must be brought into compliance with this Chapter which requires elevation of residential Structures to two (2) feet above the Base Flood elevation or the elevation/Floodproofing of non-residential Structures to two (2) feet above the Base Flood elevation. B. Specific Standards: 1. In all areas identified as numbered and unnumbered A zones, AE, AO and AH Zones (also known as the SFHAs), where Base Flood elevation data have been provided, as set forth in Section 11.32.060.A.2, the following provisions are required: a. Residential Construction. New Construction or Substantial Improvement of any residential Structures, including Manufactured Homes, shall have the Lowest Floor, including Basement, elevated a minimum of two (2) feet above Base Flood Elevation. All mechanical and HVAC equipment servicing the building shall be elevated to same level of two (2) feet above the Base Flood Elevation or Floodproofed. The elevation of the Lowest Floor shall be certified by a land surveyor or professional engineer, licensed by the State of Kansas, using the elevation certificate form as currently approved by FEMA. b. Nonresidential Construction. New Construction or Substantial Improvement of any commercial, industrial, or other nonresidential Structures, including Manufactured Homes, shall have the Lowest Floor, including Basement, elevated a minimum of two (2) feet above the Base Flood elevation or, together with attendant utility and sanitary facilities, be Floodproofed to a minimum of two (2) feet above the Base Flood Elevation so the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect, licensed by the State of Kansas, shall certify that the standards of this Subsection are satisfied. All Mechanical and HVAC equipment servicing the building shall be elevated to same level of two (2) feet above the Base Flood Elevation or Floodproofed. The elevation of the Lowest Floor shall be certified by a land surveyor or professional engineer, licensed by the State of Kansas, using the elevation certificate form as currently approved by FEMA. Such certification shall be provided to the Floodplain Administrator as set forth in this Chapter. c. Enclosures Below Lowest Floor. New construction and Substantial Improvements that fully enclosed areas below Lowest Floor used solely for parking of vehicles, building access, or storage in an area other than a Basement and that are subject to Flooding shall be designed to automatically equalize hydrostatic Flood forces on exterior walls by allowing for the entry and exit of Flood waters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect, licensed by the State of Kansas, or meet or exceed the following minimum criteria: i. A minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to Flooding shall be provided; and ii. The bottom of all opening shall be no higher than one (1) foot above grade. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of Flood waters. C. Manufactured or Mobile Homes: 1. All Manufactured or Mobile Homes to be placed within all unnumbered and numbered A, AE, AO and AH Zones, on the City's FIRM shall be required to be installed using methods and practices that minimize Flood damage. For the purposes of this requirement, Manufactured or Mobile Homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable State and City anchoring requirements for resisting wind forces. 2. Manufactured Homes that are placed or substantially improved within unnumbered or numbered A, AE, AO and AH Zones, on the City's FIRM on sites: a. Outside of a Manufactured Home Park or Subdivision; b. In a New Manufactured Home Park or Subdivision; c. In an expansion to and existing Manufactured Home Park or Subdivision; or d. In an existing Manufactured Home Park or Subdivision on which a Manufactured Home has incurred Substantial-Damage as the result of a Flood, shall be elevated on a permanent foundation such that the Lowest Floor of the Manufactured Home is elevated a minimum of two-foot above the Base Flood elevation and be securely attached to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. The elevation of the Lowest Floor shall be certified by a land surveyor or professional engineer, licensed by the State of Kansas. 3. All mechanical and HVAC equipment that provide service to a Manufactured Home shall be elevated to a level that is two (2) feet above the Base Flood Elevation. D. Area of Shallow Flooding (AO and AH Zones): Located within SFHAs as described in Section 11.32.050A are areas designated as AO and AH Zones. These areas have special Flood hazards associated with Base Flood depths of one (1) to three (3) feet where a clearly defined channel does not exist and where the path of Flooding is unpredictable and indeterminate. The following provisions apply: 1. AO Zones: a. All new construction and Substantial-Improvements of residential Structures, including Manufactured Homes, shall have the Lowest Floor, including Basement, elevated above the highest adjacent grade at least two (2) feet higher than the depth number specified in feet on the City's FIRM (at least two (2) feet if no depth number is specified) plus one (1) foot of freeboard. Mechanical and HVAC equipment to be elevated to the save levels as the lowest floor. b. All new construction and Substantial Improvements of any commercial, industrial, or other non-residential Structures, including Manufactured Homes, shall have the Lowest Floor, including Basement, elevated above the highest adjacent grade at least two (2) feet higher than the depth number specified in feet on the City's FIRM (at least two (2) feet if no depth number is specified) plus one (1) foot of freeboard. Mechanical and HVAC equipment to be elevated to the save levels as the lowest floor, or together with attendant utilities and sanitary facilities, be completely Floodproofed to that level so that the Structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. c. Adequate drainage paths shall be required around Structures on slopes, in order to guide Floodwaters around and away from proposed Structures. 2. AH Zones: a. The specific standards for all Areas of Special Flood Hazard where Base Flood elevation has been provided shall be required as set forth in Section 11.32.060B. b. Adequate drainage paths shall be required around Structures on slopes, in order to guide Floodwaters around and away from proposed Structures. E. Floodway. Located within SFHAs described in Section 11.32.050A, are areas designated as Floodways. Since the Floodway is an extremely hazardous area due to the velocity of Floodwaters that carry debris and potential projectiles, the following provisions shall apply: 1. The City shall select and adopt a Floodway based on the principle that the area chosen for the regulatory Floodway must be designed to carry the waters of the Base Flood without increasing the water surface elevation of that Flood more than one (1) foot at any point. 2. The City shall prohibit any encroachments, including fill, new construction, substantial improvements, and other Development within the adopted regulatory Floodway unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment would not result in any increase in Flood levels within the City during the occurrence of the Base Flood discharge. 3. The City may permit encroachments within the adopted regulatory Floodway that would result in an increase in Base Flood Elevations, provided that the City first applies for a conditional FIRM and Floodway revision, fulfills the requirements for such revisions as established under the provisions of 44 CFR 65.12, and receives the approval of FEMA. 4. If Section 11.32.060.E.2 is satisfied, all new construction and Substantial Improvements shall comply with all applicable Flood Hazard reduction provisions of Section 11.32.060. In unnumbered A Zones, any Base Flood elevation or Floodway data currently available from Federal, State, or other sources shall be used by the Floodplain Administrator to review the application for Development. 5. Permitted Uses. F. Recreational Vehicles. Recreational Vehicles located within all unnumbered and numbered A, AE, AO, and AH Zones on the City's FIRM shall be prohibited unless the Recreational Vehicle is: 1. On the site for fewer than one hundred eighty (180) consecutive days; 2. Fully licensed and ready for highway use; or 3. In compliance with the permitting, elevation, and anchoring requirements for Manufactured Homes as set forth in this Chapter. As used in this Section, a Recreational Vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick-disconnect type utilities and security devices, and has no permanently attached additions.

(Ord. 3395, 2021)

Ask a question about Shawnee law

Corpus searches the Shawnee sections it holds and shows the ones that match, with their citations. Free, no sign-in.