§ 15.06.020 — Amendments and Additions
Municipal Code of the City of Shawnee, Kansas (Codified through Ordinance No. 3558, adopted August 10, 2026. (Supp. No. 9, Update 2)) · Shawnee Municipal Code § 15.06.020
Corpus is an independent public-information project, not the official City of Shawnee website. Stable reference: corpuslaw.us/code/bf2de891-051a-4a9a-8d5e-d7e13f427223
15.06.020 - Amendments and Additions.
The following sections of the IRC, as adopted by Section 15.06.010, are amended as follows: A. Amend Section R101.1 Title., of the IRC, by replacing "[NAME OF JURISDICTION]" with "City of Shawnee, Kansas." B. Amend by omitting Sections R103, R104, R105, R106, R107, R108, R109, R110, R111, R112, R113 and R114 of the IRC, in their entirety, and amend by adding a new Section R103, which reads: SECTION R103 ADMINISTRATIVE PROVISIONS R103.1 Administrative Provisions. The administrative provisions of the 2024 International Building Code, Chapter 1, in its entirety, and as modified by the Shawnee Municipal Code, along with Sections R101 and R102 of the IRC, shall govern all matters within the scope of this code. C. Amend by omitting Table R301.2(1) Climatic and Geographic Design Criteria, of the IRC, and amend by adding in lieu thereof a new Table R301.2(1) Climatic and Geographic Design Criteria, which reads: TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Load | Wind Design | Seismic Design Categ. | Subject to Damage | Winter Design Temp. | Ice Barrier Underlayment | Flood Hazards | Air Freezing Index | Mean Annual Temp Speed (mph) | Topographic Effects | Special Wind Region | Wind- borne Debris Zone | Weathering | Frost line depth | Termite 20 | 115 | No | No | No | A | Severe | 36 | Moderate to heavy | 6° F | Yes | a) 11/14/1978 b) 8/3/2009 c) Panel #s 20091C0001G through 20091C0007G and 20091C0016G through 20091C9022G and 20091C0030G through 20091C0037G | 1000 | 54.7 For SI: 1 pound per square foot = 0.0479kN/m.0 squared, 1 mile per hour = 1.609km/h D. Amend the IRC by adding a new Section R302.7.1 Under Stairway Protection, which reads: R302.7.1 Under Stairway Protection. Under-stair surfaces of stairways shall be protected with ½-inch gypsum board. EXCEPTIONS: 1. Exterior stairways. 2. Stairways of noncombustable materials. 3. Decorative and open stairways where approved by the building official. E. Amend by omitting Section R303.4 Mechanical Ventilation., of the IRC, and amend by adding in lieu thereof a new Section R303.4 Mechanical Ventilation., which reads: R303.4 Mechanical Ventilation. Where the air infiltration rate of a dwelling unit is less than three (3) air changes per hour when tested with a blower door at a pressure of 0.2 inch w.c. (50 Pa) in accordance with Section N1102.4.1.2, the dwelling unit shall be provided with whole-house ventilation in accordance with Section M1507.3. F. Amend the IRC by omitting all of Section R313 AUTOMATIC FIRE SPRINKLER SYSTEMS, of the IRC, and amend by adding in lieu thereof a new Section R313 AUTOMATIC FIRE SPRINKLER SYSTEMS, which reads: SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS R313.1 General. An automatic fire sprinkler system shall be provided throughout all structures that contain four (4) or more townhouses. R313.2 Design and Installation. Automatic sprinkler systems required by this code shall be designed and installed in accordance with Section P2904 or NFPA 13D. G. Amend the IRC by omitting all of Section R314.2.2 Alterations, Repairs and Additions., of the IRC, and amend by adding in lieu thereof a new Section R314.2.2 Alterations, Repairs and Additions, which reads: R314.2.2 Alterations, Repairs and Additions. Where alterations, repairs or additions requiring a permit occur, the individual dwelling unit shall be equipped with smoke alarms and carbon monoxide alarms located as required for new dwellings. EXCEPTIONS: 1. Work involving the exterior surfaces of dwellings, such as the replacement of roofing or siding, or the addition or replacement of windows or doors, or the addition of a porch or deck, are exempt from the requirements of this section. 2. Installation, alteration or repairs of plumbing, mechanical or electrical systems are exempt from the requirements of this section. H. Amend the IRC by adding a new Section R314.8 Heat Detectors, which reads: R314.8 Heat Detectors. Any integral or attached garage to the main house shall be provided with a single heat detector. Heat detectors shall be hard wired and interconnected with the household smoke alarm system, such that the activation of the heat detector will activate all of the audible alarms of the required household smoke alarm system. The required heat detector is not required to incorporate audible alarm notification nor is any audible notification device required in the garage. The heat detector shall be listed for the ambient environment and installed per the manufacturer's installation instructions. EXCEPTIONS: I. Heat detectors shall not be required with alterations, repairs or additions. J. Heat detectors shall not be required in detached garages. L. Amend by omitting Section 326 Swimming Pools, Spas and Hot Tubs., of the IRC and amend by adding in lieu thereof a new Section R326 Swimming Pools, Spas and Hot Tubs, which reads: Section R326 Swimming Pools, Spas and Hot Tubs 326.1 General. The provisions of this Chapter shall control the design and construction of swimming pools, spas and hot tubs installed in or on the lot of a one- or two-family dwelling. 326.2 Pools in Flood Hazard Areas. Pools that are located in flood hazard areas including above-ground pools, on-ground pools and in-ground pools that involve placement of fill, shall comply with Section 328.2.1 or 328.2.2. EXCEPTIONS: Pools located in riverine flood hazard areas which are outside of designated floodways. 326.2.1 Pools Located in Designated Floodways. Where pools are located in designated floodways, documentation shall be submitted to the Building Official which demonstrates that the construction of the pool will not increase the design flood elevation at any point within the jurisdiction. 326.2.2 Pools Located Where Floodways Have Not Been Designated. Where pools are located where design flood elevations are specified but floodways have not been designated, the applicant shall provide a floodway analysis that demonstrates that the proposed pool will not increase the design flood elevation more than 1 foot (305 mm) at any point within the jurisdiction. 326.3 Definitions. For the purposes of these requirements, the terms used shall be defined as follows and as set forth in Chapter 2. BARRIER. A fence, wall, building wall or combination thereof which completely surrounds the swimming pool and obstructs access to the swimming pool. SWIMMING POOL, Hot Tube and Spas. Any structure intended for swimming or recreational bathing that contains water more than 24 inches (610 mm) deep. This includes in-ground, above ground and on-ground swimming pools, hot tubs and spas. 326.4 In-Ground Pools. In-ground pools shall be designed and constructed in compliance with ANSI/NSPI-5. 326.5 Above-Ground and On-Ground Pools. Above ground and on-ground pools shall be designed and constructed in compliance with ANSI/NSPI-4. 326.6 Permanently Installed Spas and Hot Tubs. Permanently installed spas and hot tubs shall be designed and constructed in compliance with ANSI/NSPI-3. 326.7 Portable Spas and Hot Tubs. Portable spas and hot tubs shall be designed and constructed in compliance with ANSI/NSPI-6. 326.8 Barrier Requirements. The provisions of this section shall apply to the design of barriers for restricting entry into areas having pools and spas. Outdoor pools and spas and indoor swimming pools and spas shall be surrounded by a barrier that complies with Sections 328.8.1 through 328.8.10. Where premanufactured spas or hot tubs are equipped with a lockable safety cover complying with ASTM F1346, the areas where those spas or hot tubs are located shall not be required to comply with Sections 328.8.1 through 328.8.10. Where swimming pools are equipped with a powered safety cover that complies with ASTM F1346 and surrounded by a 4-foot fence with latching gates that does not allow passage of a 5-inch sphere, the areas where those pools are located shall not be required to comply with Sections 328.8.1 through 328.8.10. 326.8.1 Barrier height and clearances. Barrier heights and clearances shall be in accordance with all of the following: 1. The top of the barrier shall be not less than 48 inches (1219 mm) above grade where measured on the side of the barrier that faces away from the pool or spa. 2. The vertical clearance between grade and the bottom of the barrier shall not exceed 2 inches (51 mm) for grade surfaces that are not solid, such as grass or gravel, where measured on the side of the barrier that faces away from the pool or spa. 3. The vertical clearance between a surface below the barrier to a solid surface, such as concrete, and the bottom of the required barrier shall not exceed 4 inches (102 mm) where measured on the side of the required barrier that faces away from the pool or spa. 4. Where the top of the pool or spa structure is above grade, the barrier shall be installed on grade or shall be mounted on top of the pool or spa structure. Where the barrier is mounted on the top of the pool or spa, the vertical clearance between the top of the pool or spa and the bottom of the barrier shall not exceed 4 inches (102 mm). 326.8.2 Openings. Openings in the barrier shall not allow passage of a 4-inch-diameter (102 mm) sphere. 326.8.3 Solid barrier surfaces. Solid barriers that do not have openings shall not contain indentations or protrusions that form handholds and footholds, except for normal construction tolerances and tooled masonry joints. 326.8.4 Closely spaced horizontal members. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than 45 inches (1143 mm), the horizontal members shall be located on the pool or spa side of the fence. Spacing between vertical members shall not exceed 1¾ inches (44 mm) in width. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1¾ inches (44 mm) in width. 326.8.5 Widely spaced horizontal members. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is 45 inches (1143 mm) or more, spacing between vertical members shall not exceed 4 inches (102 mm). Where there are decorative cutouts within vertical members, the interior width of the cutouts shall not exceed 1¾ inches (44 mm). 326.8.6 Chain link dimensions. The maximum opening formed by a chain link fence shall be not more than 1¾ inches (44 mm). Where the fence is provided with slats fastened at the top and bottom that reduce the openings, such openings shall be not greater than 1 ¾ inches (44 mm). 326.8.7 Diagonal members. Where the barrier is composed of diagonal members, the maximum opening formed by the diagonal members shall be not greater than 1¾ inches (44 mm). The angle of diagonal members shall be not greater than 45 degrees (0.79 rad) from vertical. 326.8.8 Doors and gates. Doors and gates in barriers shall comply with the requirements of Sections 328.8.8.1 through 328.8.8.2 and shall be equipped to accommodate a locking device. Pedestrian access doors and gates shall open outward away from the pool or spa, shall be self-closing and shall have a self-latching device. Doors and gates shall not swing over stairs 326.8.8.1 Utility or service doors and gates. Doors and gates not intended for pedestrian use, such as utility or service doors and gates, shall remain locked when not in use. 326.8.8.2 Latch release. For doors and gates in barriers, the door and gate latch release mechanisms shall be in accordance with the following: 1. Where door and gate latch release mechanisms are accessed from the outside of the barrier and are not of the self-locking type, such mechanism shall be located above the finished floor or ground surface not less than 54 inches (1372 mm). 2. Where door and gate latch release mechanisms are of the selflocking type such as where the lock is operated by means of a key, an electronic opener or the entry of a combination into an integral combination lock, the lock operation control and the latch release mechanism shall be located above the finished floor or ground surface at not greater than 54 inches (1372 mm). 3. Where the only latch release mechanism of a self-latching device for a gate is located on the pool and spa side of the barrier, the release mechanism shall be located at a point that is at least 3 inches (76 mm) below the top of the gate. 326.8.9 Structure wall as a barrier. Where a wall of a dwelling or structure serves as part of the barrier and where doors, gates or windows provide direct access to the pool or spa through that wall, one of the following shall be required: 1. Operable windows having a sill height of less than 48 inches (1219 mm) above the indoor finished floor, doors and gates shall have an alarm that produces an audible warning when the window, door or their screens are opened. The alarm shall be listed and labeled as a water hazard entrance alarm in accordance with UL 2017. 2. A safety cover that is listed and labeled in accordance with ASTM F1346 is installed for the pools and spas. 3. An approved means of protection, such as self-closing doors with self-latching devices, is provided. Such means of protection shall provide a degree of protection that is not less than the protection afforded by Item 1. 326.8.10 Onground residential pool structure as a barrier. An onground residential pool wall structure or a barrier mounted on top of an onground residential pool wall structure shall serve as a barrier where all of the following conditions are present: 1. Where only the pool wall serves as the barrier, the bottom of the wall is on grade, the top of the wall is not less than 48 inches (1219 mm) above grade for the entire perimeter of the pool, the wall complies with the requirements of Section 328.8. 2. Where a barrier is mounted on top of the pool wall, the top of the barrier is not less than 48 inches (1219 mm) above grade for the entire perimeter of the pool, and the wall and the barrier on top of the wall comply with the requirements of Section 328.8. 3. Ladders or steps used as means of access to the pool are capable of being secured, locked or removed to prevent access except where the ladder or steps are surrounded by a barrier that meets the requirements of Section 328.8. 4. Barriers that are mounted on top of onground residential pool walls are installed in accordance with the pool manufacturer's instructions. 326.8.11 Natural barriers. In the case where the pool or spa area abuts the edge of a lake or other natural body of water, public access is not permitted or allowed along the shoreline, and required barriers extend to and beyond the water's edge not less than 18 inches (457 mm), a barrier is not required between the natural body of water shoreline and the pool or spa. J. Amend the IRC by adding a new Section R328 PHYSICAL SECURITY, which reads: SECTION R328 PHYSICAL SECURITY R328.1 Purpose. The purpose of this Section is to establish minimum standards that incorporate physical security to make dwelling units resistant to unlawful entry. R328.1.1 Scope. The provisions of this Section shall apply to all new structures. R328.2 Doors. Except for vehicular access doors, all exterior swinging doors of residential buildings and attached garages, including the doors leading from the garage area into the dwelling, shall comply with Sections R 328.2.1 through R328.4.4. For purposes of this Section, doors leading from the garage area into the dwelling shall be deemed to be exterior doors. R328.2.1 Wood Doors. Where installed, exterior wood doors shall be of solid core construction such as high-density particleboard, solid wood, or wood block core with a minimum thickness of one and three-fourths inches (1 ¾") at any point. Doors with panel inserts shall be solid wood. The panels shall be a minimum of one inch (1") thick. The tapered portion of the panel that inserts into the groove of the door shall be a minimum of one-quarter inch (¼") thick. The groove shall be a dado groove or applied molding construction. The groove shall be a minimum of one-half inch (½") in depth. R328.2.2 Steel Doors. Where installed, exterior steel doors shall be a minimum thickness of twenty-four (24) gauge. R328.2.3 Fiberglass Door. Fiberglass doors shall have a minimum skin thickness of one-sixteenth inch (1/16") and have reinforcement material at the location of the deadbolt. R328.2.4 Double Doors. Where installed, the inactive leaf of an exterior double door shall be provided with flush bolts having an engagement of not less than one inch into the head and threshold of the doorframe. R328.2.5 Sliding Doors. Where installed, exterior sliding doors shall comply with all of the following requirements: 1. Sliding door assemblies shall be installed to prevent the removal of the panels and the glazing form the exterior with the installation of shims or screws in the upper track. 2. All sliding glass doors shall be equipped with a secondary locking device consisting of a metal pin or a surface mounted bolt assembly. Metal pins shall be installed at the intersection of the inner and outer panels of the inside door and shall not penetrate the frames exterior surface. The surface mounted bold assembly shall be installed at the base of the door. R328.3 Door Frames. The exterior door frames shall be installed prior to a roughin inspection. Doorframes shall comply with Sections R328.3.1 through R328.3.3 for the type of assembly installed. R328.3.1 Wood Frames. Wood doorframes shall comply with all of the following requirements: 1. All exterior door frames shall be set in frame openings constructed of double studding or equivalent construction, including garage doors, but excluding overhead doors. Doorframes, including those with sidelights shall be reinforced in accordance with ASTM F476-84 Grade 40. 2. In wood framing, horizontal blocking shall be placed between studs at the door lock height for three (3) stud spaces or equivalent bracing on each side of the door opening. R328.3.2 Steel Frames. All exterior door frames shall be constructed of eighteen (18) gauge or heavier steel, and reinforced at the hinges and strikes. All steel frames shall be anchored to the wall in accordance with manufacturer specifications. Supporting wall structures shall consist of double studding or framing of equivalent strength. Frames shall be installed to eliminate tolerances inside the rough opening. R328.3.3 Doorjambs. Doors jambs shall comply with all of the following requirements: 1. Doorjambs shall be installed with solid backing in a manner so no void exists between the strike side of the jamb and the frame opening for a vertical distance of twelve inches (12") each side of the strike. Filler material shall consist of a solid wood block. 2. Door stops on wooden jambs for in-swinging doors shall be of one-piece construction. Jambs for all doors shall be constructed or protected as to prevent violation of the strike. R328.4 Door Hardware. Exterior door hardware shall comply with Sections R328.4.1 through R328.4.6. R328.4.1 Hinges. Hinges for exterior swing doors shall comply with the following: 1. At least two (2) screws, three inches (3") in length, penetrating at least one inch (1") into wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and doorframe behind each hinge. 2. Hinges for out-swinging doors shall be equipped with mechanical interlock to preclude the removal of the door from the exterior. R328.4.2 Strike Plates. Exterior door strike plates shall be a minimum of eighteen (18) gauge metal with four (4) offset screw holes. Strike plates shall be attached to wood with not less than three inch (3") screws, which shall have a minimum of one inch (1") penetration into the nearest stud. Note: For side lighted units, refer to Section R328.4.6. R328.4.3 Locks. Exterior doors shall be provided with a locking device complying with one of the following: Single Cylinder Deadbolt shall have a minimum projection of one inch (1"). The deadbolt shall penetrate at least three-fourths inch (¾") into the strike receiving the projected bolt. The cylinder shall have a twist resistant, tapered hardened steel cylinder guard. The cylinder shall have a minimum of five (5) pin tumblers, shall be connected to the inner portion of the lock by solid metal connecting screws at least one-fourth inch (¼") in diameter and two and one-fourth inches (2 ¼") in length. Bolt assembly (bolt housing) unit shall be of single piece construction. All deadbolts shall meet ANSI Grade 2 or Grade 3 specifications. R328.4.4 Entry Vision and Glazing. All main or front entry doors to dwelling units shall be arranged so that the occupant has a view of the area immediately outside the door without opening the door. The view may be provided by a door viewer having a field of view of not less than one hundred eighty (180) degrees through windows or through view ports. R328.4.5 Side Lighted Entry Doors. Side light door units shall have framing of double stud construction or equivalent construction complying with Section R328.3.1, R328.3.2 and R328.3.3. The doorframe that separates the door opening from the side light, whether on the latch side or the hinge side, shall be double stud construction or equivalent construction complying with Sections R328.3.1 and R328.3.2. Double stud construction or construction of equivalent strength shall exist between the glazing unit of the side light and wall structure of the dwelling. R328.5 Street Numbers. Street numbers shall comply with Section R319. R328.6 Exterior Lighting. Exterior lighting shall comply with Sections R328.6.1 through R328.6.2. R328.6.1 Front and Street Side Exterior Lighting. All front and street side door entrances should be protected with a minimum of one light outlet having a minimum of sixty (60) watts of lighting (or energy efficient equivalent) installed so that the light source is not readily accessible. R328.6.2 Rear Exterior Lighting. Homes with windows or doors near ground level below eight feet (8') on the rear side of the house shall be equipped with a minimum of one light outlet having one hundred (100) watt lighting (or energy efficient equivalent) and shall be of the flood light type. Those fixtures placed below eight feet (8') shall be fixtures manufactured such that the light source is not readily accessible. R328.7 Alternate Materials and Methods of Construction. The provisions of this Section are not intended to prevent the use of any material or method of construction not specifically prescribed by this Section, provided any such alternate has been approved by the enforcing authority, nor is it the intention of this Section to exclude any sound method of structural design or analysis not specifically provided for in this Section. The materials, methods or construction and structural design limitations provided for in this Section shall be used, unless the enforcing authority grants exception. The enforcing authority is authorized to approve any such alternate provided they find the proposed design, materials, and methods of work to be at least equivalent to those prescribed in this Section in quality, strength, effectiveness, burglary resistance, durability, and safety. K. Amend the IRC by adding a new Section R329 FENCE MATERIALS, which reads: SECTION R329 FENCE MATERIALS R329.1 Materials. All fences, regardless of whether or not a permit is required for their construction, that are constructed, repaired, expanded, or enlarged after the effective date of this ordinance, shall be constructed only of approved fence materials. Approved fence materials shall mean materials normally manufactured for, used as, and recognized as, fencing materials such as: wrought iron or other decorative metals suitable for the construction offences, masonry, concrete, stone, chain link, metal tubing, wood planks, and vinyl or fiberglass composite manufactured specifically as fencing materials that are approved by the Building Official. Approved fence materials shall be approved for exterior use and shall be weather and decay-resistant. The Building Official is authorized to evaluate proposed fence materials, and to determine if the proposed material is satisfactory and complies with the intent of the provisions of this code, and that the material is, for the purposed intended, at least the equivalent of that prescribed in this Chapter in quality, strength, effectiveness, durability and safety. R329.2 Temporary Fencing. The Building Official is authorized to approve temporary fencing, such as plastic silt fence and safety fencing, for active construction projects. Temporary fencing shall not remain in place longer than is necessary to perform its function. L. Amend by omitting Section R402.1 Wood Foundations., of the IRC, and amend by adding in lieu thereof a new Section R402.1 Wood Foundations., which reads: R402.1 Wood Foundations. Wood foundation systems are not allowed. All other references in this code to wood foundations systems are null and void. M. Amend the IRC by adding a new Section R403.1.1.1 Continuous Footing Reinforcement., which reads: R403.1.1.1 Continuous Footing Reinforcement. Continuous footing for basement foundation walls shall have minimum reinforcement consisting of not less than two (2) No. 4 bars, uniformly spaced, located a minimum 3 inches (3") clear from the bottom of the footing. N. Amend the IRC by adding a new Section R403.1.1.2 Column Pads., which reads: R403.1.1.2 Column Pads. Column pads shall be a minimum of twenty-four inches (24") and eight inches (8") deep (24"x24"x8"). Reinforcement shall consist of a minimum of three (3) No. 4 bars each way, uniformly spaced. Deck column pads shall be a minimum of twelve inches (12") in diameter and six inches (6") in thickness, and shall extend below the frost line specified in Table R301.2(1), unless specifically approved otherwise by the Building Official. O. Amend by omitting Section R404.1.1 Design Required., of the IRC, and amend by adding in lieu thereof a new Section R404.1.1 Design Required., which reads: R404.1.1 Design Required. A design in accordance with accepted engineering practice shall be provided for concrete or masonry foundation walls, including top of wall restraint details, when any of the conditions 1 through 10 listed below exist. A design in accordance with accepted engineering practice shall be provided for concrete slabs when conditions number eleven (11) exists. Where applicable, a standard design approved by the City may be used in lieu of a design from the design professional. For new single family dwellings where standard designs approved by the City are used, the design professional sealing the plans shall specify the use of those designs on the approved plans or through a separate report. 1. Walls are subject to hydrostatic pressure from ground water. 2. Walls supporting more than 48 inches (48") of unbalanced backfill that do not have permanent lateral supports at the top and bottom. 3. Sites containing CH, MH, OL or OH soils as identified in Table R405.1. 4. Foundation walls exceeding nine feet (9') in height, measured from the top of the wall to the bottom of the slab. 5. Lots identified on the subdivision grading plan as having more than six feet (6') of fill or having a finished slope steeper than 4 horizontal to 1 vertical before grading. 6. Footings and foundations with existing fill soils below the footing level. 7. Sloping lots steeper than 4 to 1 before grading. 8. Lots where some footings will bear on soil and others will bear on rock. 9. Areas where problems have historically occurred. 10. Stepped footing and foundation walls. 11. Concrete floor slabs supported on more than twenty-four inches (24") of clean sand or gravel fill or eight inches (8") of earth fill. P. Amend by omitting Section R404.4 Retaining Walls., of the IRC, and amend by adding in lieu thereof a new Section R404.4 Retaining Walls., which reads: R404.4 Retaining Walls. Retaining walls that are not laterally supported at the top and that retain in excess of forty-eight inches (48") (1219 mm) of unbalanced fill shall be designed to ensure stability against overturning, sliding, excessive foundation pressure and water uplift. Retaining walls shall be designed for a safety factor of 1.5 against lateral sliding and overturning. Q. Amend by omitting Section R405.1 Concrete or Masonry Foundations., of the IRC, and amend by adding in lieu thereof a new Section R405.1 Concrete or Masonry Foundations., which reads: R405.1 Concrete or Masonry Foundations. Drains shall be provided around all concrete or masonry foundations that retain earth and enclose habitable or usable spaces located below grade. Drainage tiles, gravel or crushed stone drains, perforated pipe or other approved systems or material shall be installed at or below the area to be protected and shall discharge by gravity or mechanical means into an approved drainage system. Gravel or crushed stone drains shall extend at least one foot (1') beyond the outside edge of the footing and six inches (6") above the top of the footing and be covered with an approved filter membrane material. The top of open joints of drain tiles shall be protected with strips of building paper. Perforated drains shall be surrounded with an approved filter membrane or the filter membrane shall cover the washed gravel or crushed rock covering the drain. Drainage tiles or perforated pipe shall be placed on a minimum of two inches (2") of washed gravel or crushed rock at least one sieve size larger than the tile joint opening or perforation and covered not less than six inches (6") of the same material. EXCEPTIONS: 1. A drainage system is not required when the foundation is installed on well drained ground or sand-gravel mixture soils according to the Unified Soil Classification System, Group I Soils, as detailed in Table R405.1. 2. A filter membrane is not required where perforated drains are covered with at least eighteen inches (18") of washed gravel or crushed rock. 3. For gravel or crushed stone drains a filter membrane is not required when the gravel or crushed stone extends at least eighteen inches (18") above the top of the footing. R. Amend by omitting Section R502.6.2 Joist Framing., of the IRC, and amend by adding in lieu thereof a new Section R502.6.2 Joist Framing., which reads: R502.6.2 Joist Framing. Joist framing into the side of a wood girder shall be supported by approved framing anchors or on ledger strips not less than nominal two inches by two inches (2" by 2") or (51mm by 51 mm). Where joists run parallel to foundation walls, solid blocking for a minimum of three (3) joist spaces shall be provided at a maximum of 3 feet (3') centers to transfer lateral loads on the wall to the floor diaphragm. Each piece of blocking shall be securely nailed to joists, sill place and flooring with not less than three (3) eight penny nails at each connection. Where applicable, a standard design approved by the City and shown on the approved plans may be used in lieu of this requirement. S. Amend the IRC by adding a new Section R506.3 Floor Slab Placement., which reads: 506.3 Floor Slab Placement. Basement floor slabs shall be isolated from the column pads, interior columns and interior bearing walls by an approved material or barrier to act as a bondbreaker. Interior columns and bearing walls shall be supported on a separate interior footing, not on top of the floor slab. Two (2) layers of fifteen (15) pound asphalt-impregnated felt will be considered adequate to act as a bondbreaker between the basement floor slab from the columns and column footings, and interior bearing walls. T. Amend by omitting Section R602.6.1 Drilling and Notching of Top Plate., of the IRC, and amend by adding in lieu thereof a new Section R602.6.1 Drilling and Notching of Top Plate., which reads: R602.6.1 Drilling and Notching of Top Plate. When piping or ductwork is placed in or partly in an exterior wall or interior load-bearing wall, necessitating cutting, drilling or notching of the top plate by more than fifty percent (50%) of its width, a galvanized metal tie not less than 0.054 inch thick (16 ga) and one and one-half inches (1 ½") wide shall be fastened across and to the plate at each side of the opening with not less than four 10d (0.148 inch diameter) nails having a minimum length of one and one-half inches (1 ½") at each side or equivalent. The metal tie must extend a minimum of six inches (6") past the opening. See Figure R602.6.1. EXCEPTION: When the entire side of the wall with the notch or cut is covered by wood structural panel sheathing. U. Amend by omitting Section R703.2 Water-Resistive Barrier., of the IRC, and amend by adding in lieu thereof a new Section R703.2 Water-Resistive Barrier., which reads: R703.2 Water-Resistive Barrier. One (1) layer of No. 15 asphalt felt, free from holes and brakes, complying with ASTM D226 for Type 1 felt or other approved water resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the upper layer lapped over the lower layer not less than two inches (2"). Where joints occur, felt shall be lapper not less than 6 inches (6"). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. EXCEPTION: Omission of the water-resistive barrier is permitted in the following situations: 1. In detached accessory buildings. V. Amend by omitting Section N1101.5 (R103.2) Information on Construction Documents., of the IRC. W. Amend by omitting Section N1101.13 (R401.2) Compliance., of the IRC, and amend by adding in lieu thereof a new Section N1101.13 (R401.2) Compliance., which reads: N1101.13 (R401.2) Compliance. Projects shall comply with one of the following: 1. Sections N1101.14 through N1104. 2. Section N1105 and the provisions of Sections N1101.14 through N1104 indicated as mandatory. 3. The energy rating index (ERI) approach in Section N1106. The permit applicant of record must elect which compliance will be followed at the time permit application is made. The energy rating index option can be met by hiring a HERS rater and constructing a residence that scores 80 or less on the HERS index. A Preliminary HERS Certificate with 'Draft' watermark or a copy of a REM/Rate compliance report with 'Draft' watermark must be submitted with building permit plans. The 'Draft' HERS certificate or report shall identify the project address, and include the HERS raters name and contact information. All HERS ratings shall be performed by a rater accredited by the Residential Energy Services Network (RESNET). The HERS rater is required to perform a blower door test, duct blaster test, pre-drywall inspection and final inspection as part of the standard HERS Index rating process. The final HERS Index score must be posted on the Certificate required by Section N1101.14 (R401.3). The final HERS Certificate which indicates that the dwelling unit achieved a compliant HERS Index score must be submitted to the City before issuance of a Certificate of Occupancy. The final HERS certificate shall identify the project address, and include the HERS raters name and contact information. X. Amend by omitting Table N1102.1.2 (R402.1.2) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT, of the IRC, and amend by adding in lieu thereof a new Table N1102.1.2 (R402.1.2) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT, which reads: Table N1102.1.1 (R402.1.1) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT a Climate Zone | Fenestration U-factor b | Skylight b U-factor | Glazed Fenestration SHGC b | Ceiling R-Value | Wood Frame Wall R-Value | Mass Wall R-Value e | Floor R-Value | Basement Wall R-Value c | Slab d R-Value & Depth | Crawl Space c Wall R-Value 4 | 0.35 | 0.55 | 0.40 | 49 | 13 | 8/13 | 19 | 10/13 | NR | 10/13 a. R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the installed R-value of the insulation shall not be less that the R-value specified in the table. b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. c. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement walls. d. NR shall mean no requirement. e. The second R-value applies when more than half the insulation is on the interior of the mass wall. Y. Amend by omitting Section N1102.4.1.2 (R402.4.1.2) Testing., of the IRC, and amend by adding in lieu thereof a new Section N1102.4.1.2 (R402.1.2) Testing., which reads: N1102.4.1.2 (R402.1.2) Testing (Mandatory). The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the Building Official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the Building Official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During Testing: 1. Exterior windows and doors, fireplaces and stove doors shall be closed, but not sealed, beyond the intended weather stripping or other infiltration control measure; 2. Dampers including exhaust, intake, makeup, air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test, shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of the test shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. Z. Amend by omitting Section N1102.4.4 (R402.4.4) Rooms Containing Fuel Burning Appliances., of the IRC. AA. Amend by omitting Section N1103.3.2.1 (R403.3.2.1) Sealed Air Handler., of the IRC. BB. Amend by omitting Section N1103.3.3 (R403.3.3) Duct Testing (Mandatory)., of the IRC, and amend by adding in lieu thereof a new Section N1103.3.3 (R403.3.3) Duct Testing (Mandatory)., which reads: N1103.3.3 (R403.3.3) Duct Testing (Mandatory). Where required by the Building Official, duct tightness shall be verified by either of the following: 1. Post construction test: Total leakage shall be less than or equal to 4 cfm (113.3L/min) per 100 square feet (9.29 m 2 ) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test: Total leakage shall be less than or equal to 4 cfm (113.3L/min) per 100 square feet (9.29 m 2 ) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3 cfm (85L/min) per 100 square feet (9.29 m 2 ) of conditioned floor area. EXCEPTIONS: 1. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. 2. On the post construction test, it is permissible to test for "leakage to the outdoors" versus a "total leakage." Leakage to the outdoors shall be less than or equal to 8 cfm per 100 square feet of conditioned floor area. CC. Amend by omitting Section N1103.3.5 (R403.3.5) Building Cavities (Mandatory)., of the IRC. DD. Amend by omitting Section N1104 ELECTRICAL POWER AND LIGHTING SYSTEMS (Mandatory)., of the IRC. EE. Amend by omitting Section N1106.2 (R406.2) Mandatory Requirements., of the IRC, and amend by adding in lieu thereof a new Section N1106.2 (R406.2) Mandatory Requirements., which reads: N1106.2 (R406.2) Mandatory Requirements. Compliance with this section requires that the provisions identified in Section 1101.13 through N1104 indicated as "mandatory" be met. The building thermal envelope shall be greater than or equal to the levels of efficiency and Solar Heat Gain Coefficients in Table N1102.1.2 (R402.1.2) and N1102.1.4 (R402.1.4). EXCEPTIONS: 1. Supply and return ducts not completely inside the building thermal envelope shall be insulated to an R-value of not less than R-6. 2. Section N1103.5.1 (R403.5.1) shall not be "mandatory." FF. Amend by omitting Table N1106.4 (R406.4) Maximum Energy Rating Index., of the IRC, and amend by adding in lieu thereof a new Table N1106.4 (R406.4) Maximum Energy Rating Index., which reads: Table N1106.4 (R406.4) Maximum Energy Rating Index Climate Zone | Energy Rating Index 4 | 80 Where on-site renewable energy is included for compliance using the ERI analysis of section N1106.4, the building shall meet the mandatory requirements of section N1106.2, and the building thermal envelope shall be greater than or equal to the levels of efficiency and SHGC in table N1102.1.2 or table N1102.1.4. GG. Amend by omitting Section P2503.2 Concealment., of the IRC, and amend by adding in lieu thereof a new Section P2503.2 Concealment., which reads: P2503.2 Concealment. A plumbing or drainage system, or part thereof, shall not be covered, concealed or put into use until it has been inspected and approved by the Building Official, or his authorized representative. A plumbing or drainage system, or part thereof, shall not be covered, concealed or put into use until it has been tested by the permittee, or his or her authorized representative. The Building Official may require that any test of the plumbing or drainage system be witnessed by the Building Official or his authorized representative. HH. Amend by omitting Section P2603..5.1 Sewer Depth., of the IRC, and amend by adding in lieu thereof a new Section P2603.5.1 Sewer Depth., which reads: P2603.5.1 Sewer Depth. Building sewers shall be installed as required by the appropriate authority having jurisdiction. II. Amend by omitting Section E3902.2 Garage and Accessory Building Receptacles., of the IRC, and amend by adding in lieu thereof a new Section E3902.2 Garage, Unfinished Basements and Accessory Building Receptacles., which reads: E3902.2 Garage, Unfinished Basements and Accessory Building Receptacles. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in garages and grade-level portions of unfinished accessory buildings used for storage or work areas shall have ground-fault circuit-interrupter protection. EXCEPTIONS: 1. A dedicated single receptacle for a garage door opener. 2. A single receptacle supplied by a dedicated branch circuit that is located and identified for specific use by cord-and plug-connected appliance such as a refrigerator or freezer. 3. A dedicated single receptacle for a sump pump. 4. A dedicated receptacle supplying a permanently installed fire alarm or security alarm system.
(Ord. No. 3646, 2026)
Ask a question about Shawnee law
Corpus searches the Shawnee sections it holds and shows the ones that match, with their citations. Free, no sign-in.