§ 15.16.020 — Amendments and Additions
Municipal Code of the City of Shawnee, Kansas (Codified through Ordinance No. 3558, adopted August 10, 2026. (Supp. No. 9, Update 2)) · Shawnee Municipal Code § 15.16.020
Corpus is an independent public-information project, not the official City of Shawnee website. Stable reference: corpuslaw.us/code/e5200d05-100e-48a2-9685-dc6a89507c91
15.16.020 - Amendments and Additions.
The following sections of the IPC, as adopted by Section 15.16.010 are amended as follows: A. Amend Section 101.1 Title., of the IPC by replacing "[NAME OF JURISDICTION]" with "City of Shawnee, Kansas.". B. Amend by omitting Sections 103, 104, 105, 106, 107, 108, 112, 113, 114 and 115 of the IPC, in their entirety, and amend by adding a new Section 103 ADMINISTRATIVE PROVISIONS, which reads: SECTION 103 ADMINISTRATIVE PROVISIONS The Administrative Provisions of the 2024 International Building Code, Chapter 1, in its entirety, and as modified by the Shawnee Municipal Code, along with Sections 101, 102, 109, 110, and 111 of the IPC, shall govern all matters within the scope of this code. C. Amend by omitting Section 305.4.1 Sewer Depth., of the IPC, and amend by adding a new Section 305.4.1 Sewer Depth., which reads: 3.4.1.1 Sewer Depth. Building sewers that connect to private sewage disposal systems shall comply with the Johnson County Sanitary Code, adopted by Johnson County, Kansas. Building sewer pipe connecting to the public sewer shall comply with the regulations of the Johnson County Wastewater District. D. Amend by omitting Section 312.3 Drainage and Vent Air Test., of the IPC, and amend by adding a new Section 312.3 Drainage and Vent Air Test., which reads: 312.3 Drainage and Vent Air Test. An air test shall be made by forcing air into the system until there is a uniform gauge pressure of 5 psi (34.5 kPa) or sufficient to balance a 10-inch column of mercury. This pressure shall be held for a period of not less than 15 minutes. Any adjustments to the test pressure required because of changes in ambient temperatures or the seating of gaskets shall be made prior to the beginning of the test period. E. Amend by omitting Section 403.2 Separate Facilities of the IBC and amend by adding lieu thereof a new Section 403.2 Separate Facilities, which reads: P2902.2 Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. Exceptions: 1. Separate toilet facilities shall not be required for dwelling units and sleeping units. 2. Separate toilet facilities shall not be required in structures or tenant spaces with a total occupant load, including both employees and customers, of 15 or fewer. 3. Separate toilet facilities shall not be required in mercantile occupancies in which the maximum occupant load is 100 or fewer. 4. Separate toilet facilities shall not be required in business occupancies in which the maximum occupant load is 25 or fewer. 5. Separate toilet facilities shall not be required to be designated by sex where single-user toilet rooms are provided in accordance with Section 2902.1.2. 6. Separate toilet facilities shall not be required where rooms having both water closets and lavatory fixtures are designed for use by all persons regardless of sex and privacy is provided for each water closet and each urinal shall occupy a separate compartment with full height (floor to ceiling) walls and door. F. Amend the IPC by adding a new Section 410.4 Substitution., which reads: 410.4 Substitution. The Building Official is allowed to accept equivalent means for providing drinking water besides requiring drinking fountains, such as free bottled water, or cleaning equipment that can be used without a service sink. G. Amend by omitting Section 703.5 Cleanouts on Building Sewers., of the IPC, and amend by adding a new Section 703.5 Cleanouts on Building Sewers., which reads: 703.5 Cleanouts on Building Sewers. Cleanouts on building sewers shall be located as required by the appropriate authority having jurisdiction. H. Amend by omitting Section 708.1.2 Building Sewers., of the IPC, and amend by adding a new Section 708.1.2 Building Sewers., which reads: 708.1.2 Building Sewers. Cleanouts on building sewers shall be provided and located as required by the appropriate authority having jurisdiction. I. Amend Section 903.1.1 Roof Extension Unprotected., of the IPC, by replacing "[NUMBER]" with "6." J. Amend by omitting Section 1003 INTERCEPTORS AND SEPARATORS, of the IPC, in its entirety, and amend by adding a new Section 1003 INTERCEPTORS AND SEPARATORS, which reads: Section 1003 - INTERCEPTORS AND SEPARATORS 10.1 .1 Where Required. Interceptors and separators shall be provided, installed, inspected, and maintained as required by the appropriate authority having jurisdiction.
(Ord. No. 3540, 2025)
Ask a question about Shawnee law
Corpus searches the Shawnee sections it holds and shows the ones that match, with their citations. Free, no sign-in.
