Sec. 20.04.040. - Minimum standards for light, ventilation, electricity and heating.

No owner or operator shall occupy as owner-occupant or permit another to occupy, any dwelling or dwelling unit, for the purpose of living therein, which does not comply with the following requirements: (1) Every habitable room shall have at least one window facing directly to the outdoors with a minimum total window area, measured between stops, for every habitable room with an area of not less than one-twelfth of the floor area of such room; provided that the Director may accept less total window area if it can be reasonably demonstrated that adequate natural daylight illumination will be available, provided, further, that positive mechanical ventilation equal to eight changes of air per hour may be provided in lieu of such windows for kitchens in buildings two or more stories in height containing four or more dwelling units. Any window with an outside vertical light obstruction, located within three feet of and facing the window and extending above the window, shall not be deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area; (2) Every habitable room shall have at least one window which can easily be opened and such openable window space shall equal at least forty-five percent of the minimum window area required in paragraph (1); or provided that positive mechanical ventilation or such other device as will adequately ventilate the room may be approved by the Director in lieu of such openable window; (3) Every bathroom and water closet room shall comply with the light and ventilation requirements for habitable rooms contained in paragraphs (1) and (2) of this section, except that no window shall be required in bathrooms and water closet rooms equipped with a ventilation system which is installed in accordance with the building code. An openable skylight, approved by the superintendent of central inspection, may be used in lieu of a window in bathrooms and water closet rooms; and (4) Every dwelling or dwelling unit shall be connected to an electrical supply, provided by an electrical utility company. Every habitable room of any existing dwelling shall contain at least three separate wall type electric convenience duplex outlets or two such convenience duplex outlets and one ceiling electric light fixture. Exception: This requirement may be reduced to at least two separate wall type electric convenience duplex outlets or one such convenience duplex outlet and one ceiling light fixture if the Director or his/her designee determines that the existing occupant load of the dwelling unit and/or the use or load of electric appliances, equipment, lights, and/or fixtures in any habitable room does not pose a safety problem or hazardous condition. Every toilet room, bathroom, laundry room, furnace room, private and public hall shall contain at least one ceiling electric light fixture or wall-type electric light fixture. Every such outlet and fixture shall be properly installed and shall be maintained in good and safe working condition, and shall be connected to the source of electric power in a safe manner; (a) The minimum capacity of the electrical service supply and the main disconnect switch shall be sufficient to adequately carry the total load required in accordance with the city electrical code. (b) Where the determination is made by the electrical inspector, upon examination of the existing electrical service supply, that the electrical service supply is being used in such manner as would constitute a hazard to the occupants or would otherwise constitute a hazard to life and property, such as but not limited to, overloading of circuits, unsafe wiring or inadequate wiring, then such conditions shall be corrected by a licensed electrical contractor of the city in conformance to the city electrical code. Exception: If the owner-occupant of a detached single-family dwelling desires to install any electrical installations on the load side of the service panelboard in the main structure or in the usual accessory buildings thereto, the owner occupant shall obtain an electrical permit as required by the city electrical code upon fulfillment of exam and plan review requirements as administered by the electrical section of the Metropolitan Area Building and Construction Department. The owner obtaining said permit shall personally purchase all materials and shall personally perform all labor in connection with the permitted project. The owner shall call for all inspections and otherwise be responsible to comply with all the applicable provisions of the city electrical code. (c) Extension cords shall not be used as a substitute for the fixed wiring of a structure if such cord runs through holes in walls, ceilings, floors, doorways, windows, or similar openings, is attached to building surfaces, or is concealed behind building walls, ceilings, or floors. (d) Smoke Detectors. Every dwelling shall have smoke detectors installed in accordance with Section 15.02 of this code. (5) Every dwelling or dwelling unit shall have heating facilities which are properly installed, are maintained in safe and good working condition, and are capable of safely and adequately heating all habitable rooms, bathrooms and water closet rooms located therein to a temperature of at least seventy degrees Fahrenheit. Such heating equipment shall be operated as reasonably necessary to allow maintenance of a temperature in all habitable rooms of seventy degrees Fahrenheit at a point three feet above the floor; (6) From April 1st to November 30th of each year, every door opening directly from a dwelling to outdoor space, used for ventilation, shall have a supplied screen door and a self-closing device; and every window or other direct opening to outdoor space from the dwelling, used for ventilation, shall likewise be supplied with screens; provided that screens shall not be required in windows or other openings above the third floor of any dwelling. All screens shall be adequate to exclude insects and of a type approved by the Director or his/her designee; (7) Every basement window used for ventilation, and every other opening to a basement which might provide an entry for rodents, shall be supplied with a screen or other such device as may be determined by the Director to effectively prevent their entrance; (8) Every public hall and stairway in or leading into a multiple dwelling shall be adequately lighted at all times so as to provide in all parts thereof at least six foot candles of light at the tread or floor level by natural or artificial means. Every public hall and stairway in structures containing not more than two dwelling units shall be supplied with conveniently located light switches controlling an adequate lighting system which may be turned on when needed, or automatic lighting system, instead of full time lighting; (9) There shall not be any unvented or improperly vented space and/or room heaters in any dwelling unit. Space and/or room heaters shall be of a type listed for vented use, and shall be connected to a vent approved for use with such appliance. If such space and/or room heaters are equipped with a pilot light, it shall be an approved automatic safety type device. Vented freestanding space and/or room heaters shall be installed with provisions for supplying sufficient combustion air and with clearance from combustible material as listed on the appliance, and in compliance with the mechanical code; (10) Every residential structure shall contain ceiling insulation material that meets the requirements of Federal Specification HH-I-515C including a flame spread factor of fifty or less and that achieves a minimum rating factor of R-19 as approved by the Director. Any ceiling insulation material that is installed hereafter in an existing residential structure shall meet the requirements of Federal Specification HH-I-515C including a flame spread factor of fifty or less as approved by the Director, and shall, in addition, contain an R rating factor label. The ceiling insulation material shall be installed in accordance with the manufacturers specifications and in a manner that achieves a minimum rating factor of R-19. R shall be defined for purposes of this section as that term is defined by the American Society of Heating, Refrigeration and Air Conditioning; (11) All existing installations and/or repairs made to conform to this and all other applicable codes, must be installed in a workmanlike manner.

(Ord. No. 44-967 § 3; Ord. No. 47-302, § 3, 11-21-06; Ord. No. 52-863, § 6, 12-16-25)

Ask a question about Wichita law

Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.