§ 7.42.050 — Testing
The Code of the City of Wichita, Kansas (Supp. No. 36, Update 1: codified through Ordinance No. 53-088, adopted July 28, 2026) · Wichita City Code § 7.42.050
Corpus is an independent public-information project, not the official City of Wichita website. Stable reference: corpuslaw.us/code/4e7f10ce-b459-4407-afd8-0e7056c15603
Sec. 7.42.050. - Testing.
(1) Testing shall be conducted by a representative of the Wichita-Sedgwick County Department of Community Health. (2) Two odor measurements shall be made within a period of one hour with these measurements separated by a minimum of fifteen-minute intervals. Both measurements must detect odors at or above the standard contained in Section 7.42.040. (3) Measurement of objectionable odorous air contaminants expressed as dilution to threshold (D/T) shall be in accordance with test procedures employed in the use of the Barnebey-Cheney Scentometer or its equivalent.
(Ord. No. 43-663 § 3)