§ 21-6 — Contents and format of development plans
Code of Ordinances, Lexington-Fayette Urban County Government, Kentucky (Republication: codified through Ordinance No. 048-2025, adopted June 26, 2025 (online July 17, 2026)) · Lexington-Fayette Zoning Ordinance § 21-6
Corpus is an independent public-information project, not the official City of Lexington-Fayette urban county website. Stable reference: corpuslaw.us/code/0f9e56fc-b079-45ce-9da3-98e46999d664
Sec. 21-6 - Contents and format of development plans.
All development plans shall be prepared on Mylar or other material capable of clear reproduction using ozalid print process. Plans shall be legible and of a size and scale (generally not exceeding one (1) inch equals one hundred (100) feet) which enables clear presentation of required information. Required plan information shall be as follows: Contents of preliminary development plan. A preliminary development plan shall contain the following information: A title block containing the plan name, development plan type, name and address of developer and plan preparer; written and graphic scale. The boundary of the subject property denoted with a solid line and bearings and distances, and its record plan designation (if available the record plan name or owner's name of all adjacent property). The boundary of all adjacent property shall be denoted with dashed lines. A vicinity sketch, oriented in the same direction as the design scheme, at a scale of one (1) inch equals two thousand (2,000) feet, labeled with roadways and identifying the subject property. Topography with contour intervals not greater than five (5) feet. Location, arrangement, and dimensions of existing and proposed driveways, walkways, pedestrian crossings, parking areas and arrangement of spaces (including reserved parking, display areas, and compact spaces), point of ingress and egress (including all gates restricting vehicular access), traffic calming elements, access points for construction vehicles, and other vehicular and pedestrian rights-of-way or easements (as required by Article 16). Location and cross-sections of any proposed or existing streets within or abutting the subject property, access points for all adjacent land, and stub connections that adjoin any portion of the subject property (both vehicular and pedestrian). Location, arrangement, and dimensions of existing and proposed screening, landscaping and buffering, (as required by Article 18), recreational and other open space areas (as required by Article 20). Location, size, height, floor area, area arrangement and use of proposed and existing buildings, walls over three feet in height, fences, and canopies over drive aisles. Storm drainage areas, floodplains, alluvial soils, conceptual drainage controls and stormwater retention and any other designated environmentally sensitive or geologic hazard area. Existing easements for utilities or other purposes, including dimensions and labels. A tree inventory map and notes as required by Article 26. Location of any existing burial grounds (including private family cemeteries) on the subject property and all adjoining property, and provisions for their protection, maintenance and accessibility. A statistical summary of all pertinent site data, including site area in square feet and acres, zoning, building coverage and floor area, parking quantities, open space by type (total, common, usable and vegetative, tree canopy, etc.). Additional site statistics may be required based on the requirements of the zoning category. Statistical summary table shall meet the standards of the Division of Planning. Proposed and existing addresses for each lot, building and/or unit, and front yard and exterior building line(s). The approved conditional zoning, variances, waivers, conditional use permits or other binding restrictions for the subject property. Preliminary Development Plans shall contain the following general notes stating the following: No grading, stripping, excavation, filling or other disturbance of the natural ground cover shall take place prior to approval of an erosion control plan. Such plan must be submitted in accordance with Chapter 16 of the Code of Ordinances. No building permits shall be issued unless and until a final development plan is certified by the Secretary of the Planning Commission. All buildings, paving, signs, fences, and retaining walls that are depicted, described or required on this Development Plan shall require a separate review and building permit from the Division of Building Inspection prior to construction. The location of the fire hydrants, fire department or fire service features, if required, shall be approved by the Division of Fire, Water Control Office. An owner's certification, signed and witnessed as follows: "I (We) do hereby certify that I am (we are) the only owner(s) of the property shown hereon, do fully agree to all graphic and textural representations shown hereon, and do adopt this as my (our) development plan for the property." A Commission's certification to be signed by the Secretary of the Commission if and when the plan is fully approved by the Planning Commission, as follows: "I do hereby certify that this development plan was approved by the Urban County Planning Commission at its meeting held on (date)." An alternative Commission's certification shall be used when the plan meets all requirements of the Zoning Ordinance and has not been acted on by the Planning Commission, as follows: "I do hereby certify that this development plan complies with all provisions of the Zoning Ordinance." Contents of final development plan. All information required for preliminary development plans as required under Subsections (a) and (b) of this section, above, except that the plan information shall be of an exact nature, rather than approximate or general. In addition, the following information shall be required: Environmentally sensitive and geologic hazard areas, as defined in Article I-11, shall also be depicted on a supplemental environmental plan sheet; Contour intervals shall be two (2) feet; A tree protection plan, data block, and tree protection areas as required by Article 26; A lighting plan as required by Article 30; and Proposed easements for utilities or other purposes, including dimensions and labels. (Code 1983, § 21-6; Ord. No. 26-88, § 1, 2-11-1988; Ord. No. 30-88, § 1, 2-25-1988; Ord. No. 26-94, § 1, 2-24-1994; Ord. No. 289-2000, § 1, 9-14-2000; Ord. No. 209-2002, § 1, 8-29-2002; Ord. No. 5-2010, § 3, 1-14-2010; Ord. No. 1-2011, § 10, 1-13-2011; Ord. No. 004-2023, § 32, 1-31-2023; Ord. No. 079-2024, § 3, 7-9-2024)
Ask a question about Lexington-Fayette urban county law
Corpus searches the Lexington-Fayette urban county sections it holds and shows the ones that match, with their citations. Free, no sign-in.