§ 28-6 — Provisions applicable to all mixed use zones
Code of Ordinances, Lexington-Fayette Urban County Government, Kentucky (Republication: codified through Ordinance No. 048-2025, adopted June 26, 2025 (online July 17, 2026)) · Lexington-Fayette Zoning Ordinance § 28-6
Corpus is an independent public-information project, not the official City of Lexington-Fayette urban county website. Stable reference: corpuslaw.us/code/403224ee-d641-4650-9adf-df151f277b4a
Sec. 28-6 - Provisions applicable to all mixed use zones.
Provisions applicable to all mixed-use zones shall be as follows: Development Plan Required. All applications for a zone map amendment shall require the accompanying submission of a preliminary development plan. No development or occupancy of any existing structure for mixed use shall occur until a final development plan has been approved and certified. In addition to all requirements for development plans contained in Article 21, the developments within these zones shall comply with provisions of Subsections (b) through (g) of this section, below. Pedestrian Accommodation. Pedestrian accommodation shall be as follows: At least one (1) primary street-level entrance to a building that faces any public street shall be oriented toward the public street. For at least one (1) location adjoining the street, a pedestrian entryway, including landscaping elements, has been provided to the site. Where two (2) or more buildings are proposed, they shall be arranged in a manner that provides a centralized open space area, such as a plaza, courtyard, or similar feature. Sidewalks shall be provided along each road frontage, with connections provided to each principal structure, parking area, and open space area. A six-foot minimum unobstructed pedestrian walkway shall be provided to accommodate landscaping, street trees, street furniture, sidewalk cafes or other obstacles. For any development within the Downtown Streetscape Master Plan Area, the development shall adhere to the provisions of that plan. Building Features. Shall be as follows: For every primary wall plane: A change of at least five (5) feet in depth and eight (8) feet in length shall be made for every eighty (80) feet of length or fraction thereof; or Implementation of a minimum of three (3) of the following for every sixty (60) feet of length or fraction thereof: A change of at least one (1) foot in depth for at least one (1) story; A change in wall height of at least two (2) feet; A change in exterior material type, style, or finish for at least one (1) story; A minimum of twenty percent (20%) of the ground floor building face shall be transparent glass, including windows and doors. For every side or rear wall plane: A change of at least eight (8) feet in length and five (5) feet in depth shall be made for every one hundred (100) feet in length; or Implementation of a minimum of three (3) of the following for every eighty (80) feet of length or fraction thereof: A change of at least one (1) foot in depth for at least one (1) story; A change in wall height of at least two (2) feet; A change in exterior material type, style, or finish for at least one (1) story; A minimum of twenty percent (20%) of the ground floor building face shall be transparent glass, including windows and doors. The primary wall plane shall provide at least one (1) of the following features at ground level: A balcony at least four (4) feet by five (5) feet. A bay window with at least a one-foot offset, containing a minimum of twenty (20) square feet. A covered entrance at least three (3) feet by three (3) feet. A porch at least four (4) feet by six (6) feet, with a floor at least twelve (12) inches above grade. A recessed entrance at least three (3) feet by five (5) feet. At least ten percent (10%) of any building face shall be transparent glass, including windows and doors. Location and Assignment of Provided Off-Street Parking. At least fifty percent (50%) of provided parking spaces shall be located so as to not project between any front building face and any adjoining street, except an alley. The Planning Commission may require designation of certain spaces for use of residents only on the development plan. Accessory Structures. Shall be regulated as follows: The sides of any parking structure shall include one (1) or more of the following features: First floor retail or office uses. Murals or public art on at least fifteen percent (15%) of the building face. Display cases on at least ten percent (10%) of the building face. Landscaping in an area of at least five (5) feet in width, with plantings as specified in Article 18 for edges of vehicular use areas. Any garage doors shall meet one (1) of the following criteria: The garage door shall face perpendicular to or away from any adjoining street. The garage door shall be offset at least four (4) feet behind the primary wall plane. If flush with the primary wall plane, the garage door shall not cover more than thirty percent (30%) of the surface area of the wall plane. Parking for Bicycles. For projects with three (3) or more dwelling units, four (4) bicycle rack spaces shall be provided per every three (3) units, with a maximum requirement of twelve (12) spaces. Increased Setback for Building Height Differences. In cases where the proposed mixed-use structure(s) have a height differential of greater than ten (10) feet from immediately adjoining residential structures, a minimum 1:1 height-to-yard ratio for the adjoining side yard shall be provided. (Code 1983, § 28-6; Ord. No. 307-2002, § 1, 12-5-2002; Ord. No. 129-2009, §§ 47, 48, 7-2-2009; Ord. No. 35-2015, § 1, 4-30-2015; Ord. Nd 13-2022, § 17, 10-27-2022; Ord. No. 036-2025, § 34, 6-12-2025)
Ask a question about Lexington-Fayette urban county law
Corpus searches the Lexington-Fayette urban county sections it holds and shows the ones that match, with their citations. Free, no sign-in.
