Sec. 24-82. - Expansion joints.

(a) Transverse expansion joints one-half inch in thickness and extending the full width of the concrete slab shall be provided at intervals not more than thirty-six (36) feet apart. These joints must be the full depth of the concrete and shall be well filled with some satisfactory and elastic joint filler approved by the city engineer. (b) Where walks or driveway transitions join or abut on the street curbing line, an expansion joint not less than three-fourths inch thick across the entire section of the walk must be made and filled as provided in subsection (a). (c) Where a new section of sidewalk is connected with a sidewalk previously constructed, a half-inch expansion joint must be made and filled as provided in subsection (a).

(Code 1955, § 20-47)