Sec. 5-19. - Fees.
(a) General: No permit will be issued until the fees prescribed in this section have been paid. No amendments to a permit will be approved until any additional fee, due to increases in the estimated cost of construction, has been paid. (b) Building Permit Violation: If in the opinion of the building official the valuation appears to be underestimated on the application, the permit will be denied unless the applicant can show a detailed estimated cost which meets the approval of the building official. (c) Schedule of Permit Fees: There shall be one (1) schedule of building permit fees for all construction classifications: residential, commercial remodeling, etc., which shall be based on construction costs. These fees shall be paid as required at the time of filing the application with the building department in accordance with the following schedule: (1) Permit fees: Total Valuation Fee $0.00 up to and including $3,000.00 .....$20.00 $3,001.00—$100,000.00: For the first $3,000.00 .....20.00 Plus, for each additional $1,000.00 or fraction thereof, to and including $100,000.00 .....3.00 $100,00.01—$500,000.00: For the first $100,000.00 .....311.00 Plus, for each additional, $1,000.00 or fraction thereof, to and including $500,000.00 .....2.00 $500,000.01—$10,000,000.00: For the first $500,000.01 .....1,111.00 Plus, for each additional $1,000.00 or fraction thereof, to and including $10,000,000.00 .....1.00 $10,000,000.01 and up: For the first $10,000,000.01 .....10,611.00 Plus, for each additional $1,000.00 or fraction thereof .....0.50 (2) Square foot construction cost: To determine the cost of construction of any building, the building inspection department shall prepare a cost chart representing each category of construction listed in Table 505 of the Kentucky Building Code based on the Building Valuation Data Report published by BOCA International, Inc. in July of each year. Copies of this chart shall be made available in the inspection department and shall be revised as necessary each July 1. Building costs shall be determined by use of the abovedescribed chart and the following explanatory material as set out beginning on page 281 and ending on page 283 of the Owensboro Municipal Code. Type 1 construction: All buildings and structures of type 1 construction are those in which the walls, partitions, structural elements, floors, ceilings, roofs and the exits are constructed and protected with approved noncombustible materials to afford the fire-resistance rating in table 401 of the Kentucky Building Code (KBC), except as otherwise specifically regulated by the provisions of article 14 of the KBC. Type 1 buildings shall be further classified as types 1A and 1B. Fire-retardant treated wood may be used as specified in table 401 and section 1403.5 of the KBC. Type 2 construction: Buildings and structures of type 2 construction are those in which the walls, partitions, structural elements, floors, ceilings, roofs and exits are constructed of approved noncombustible materials meeting the fire-resistance rating requirements specified in table 401 of the KBC, except as modified by fire limit restrictions of article 5, and as further regulated in article 14 of the KBC. Type 2 buildings shall be further classified as types 2A, 2B, and 2C. Fire-retardant treated wood may be used as specified in table 401, and section 1403.5 of the KBC. Type 3 construction: Buildings and structures of type 3 construction are those in which the exterior, fire and party walls are constructed of masonry or other approved noncombustible materials of the required fire-resistance rating and structural properties; and the floors, roofs and interior framing are wholly or partly of wood or of metal or other approved construction; the fire and party walls are ground supported, except that girders and their supports carrying walls of masonry shall be protected to afford the same degree of fire-resistance rating of the walls supported thereon and all structural elements have the required fire-resistance rating specified in table 401 of the KBC. Type 3A construction: Buildings and structures of type 3A construction are those in which the fire-resistance rating is attained by placing limitations on the minimum sizes of wood structural members and on minimum thickness and composition of wood floors and roofs; by the avoidance and composition of wood floors and roofs; by the avoidance or by the proper protection by fire stopping or other acceptable means, of concealed spaces under roofs and floors; by the use of approved fastenings, construction details, and adhesives for structural members; and by providing the required degree of fire-resistance rating in exterior and interior walls. Type 3B construction: Structures of type 3B construction shall include all type 3 buildings, in which the interior structural elements are wholly or partly of fire-protected wood of not less than two (2) inches nominal thickness or other approved protected combustible materials, or metal protected and insulated to afford the fire-resistance rating specified in table 401 of the KBC. Type 3C construction: Structures of type 3C construction shall include all type 3 buildings, in which the interior structural members are of wood of not less than two (2) inches nominal thickness or consist of other combustible or noncombustible materials with protection of less than one-hour fire-resistance rating. Type 4 construction: Buildings and structures of type 4 construction are those in which the exterior walls, bearing walls, partitions, floor and roof construction are constructed wholly or partly of wood stud and joist assemblies with a minimum nominal dimension of two (2) inches, or of other approved combustible materials; with fire stopping at all vertical and horizontal draft openings as regulated in section 1420.0 of the KBC; and in which the structural elements have the required fire-resistance ratings specified in table 401 of the KBC. Type 4 buildings shall be further classified as types 4A and 4B. (3) Moving of building or structures: For the moving of any building or structure, the fee shall be fifty dollars ($50.00). (4) Reserved. (5) Double fee: Where work for which a permit is required by this article is started or proceeded with prior to obtaining the permit, the fees herein specified shall be doubled, but the payment of such double fee shall not relieve any persons from fully complying with the requirements of this article in the execution of the work nor from any other penalties prescribed herein. (6) Reserved. (7) Reserved.
(Code 1955, § 5-4; Ord. No. 9-85, 5-7-85; Ord. No. 11-93, §§ 1, 2, 4-20-93; Ord. No. 38-2004, 12-7-2004)
Ask a question about Owensboro law
Corpus searches the Owensboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.