§ 14.7 — Individual Manufactured Home Space Requirements
Code of Ordinances of the City of Bossier City, Louisiana (Codified through Ordinance No. 182-2025, adopted December 2, 2025 (Supp. No. 23)) · Bossier City Code of Ordinances § 14.7
Corpus is an independent public-information project, not the official City of Bossier City website. Stable reference: corpuslaw.us/code/13d9780a-8eb3-428a-81d2-80213090f0c1
Sec. 14.7 - Individual Manufactured Home Space Requirements.
14.7.1 Minimum Lot Width and Depth. Spaces for manufactured homes must be a minimum of 35 feet. Individual spaces shall be designed with enough depth to accommodate a manufactured home that is eighty (80) feet in length and meet all building setbacks required in this Article and lot area requirements of Section 6.2. 14.7.2 Access. In addition to the dimensional standards contained in this Article, manufactured housing parks shall comply with the applicable design standards in Article 12. Each space must have access to a street constructed in accordance with the requirements in Subsection 14.6.2. Site Plan Review, as specified in Section 3.7 is required for initial approval or expansion. 14.7.3 Other Requirements. A. Drainage and Utility Systems. 1. Each unit shall be provided adequate drainage and utility easements approved by the City or Parish Engineer. 2. The park owner shall meet the minimum requirements established of all utility providers. B. Sanitation. The park owner shall provide for solid waste and trash pickup and disposal. C. Tie-Downs. Every manufactured home to be located in a manufactured housing park shall be equipped with adequate foundations and tie-downs, intended to secure such units against movement, settling and overturning. 1. Number of Tie-Downs Required. All manufactured housing sites shall be provided with tie-downs in accordance with Table 14.7.3. Table 14.7.3 Manufactured Home Park Tie-Down Requirements Length of Frame | Number of Ties Up to 30 feet | 2 per side 30 feet to 49 feet | 3 per side 50 feet to 69 feet | 4 per side 70 feet or longer | 5 per side 2. Ground Anchors. In instances where the unit is not tied down to a slab, ground anchors may be provided. The following standards shall apply: a. Anchors shall be bolted on concrete, screw auger or anchor driven or any other type manufactured and approved for use. b. All anchors shall be galvanized, high tensile steel, not less than ⅝ inch in diameter, with drop forged closed eye or any other approved method of anchorage. All anchors shall be at least 4 feet long, installed to full depth according to manufacturers' recommendation, with only the eye protruding above grade for connecting the tie-down system. c. Connections to the housing unit I-beam frame shall be a ⅝ inch or larger drop forged closed eye, bolted through a hole drilled through the frame or by any other approved and adequate wrap-around, hood or clamp method. d. Drop forged turnbuckles no less than ⅝ inch with closed eyes and screw pins shall be attached to the frame above and to the ground anchor below, and securely tightened in place. Steel straps or cables may be used in lieu of turnbuckles if they are of equal or greater strength and are securely tightened in place with a tensioning tool and clamped.
Ask a question about Bossier City law
Corpus searches the Bossier City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
