Sec. 18-315. - Water test of drainage system.
The water test may be applied to the drainage system in its entirety or in sections. If applied to the entire system, all openings in the piping shall be tightly closed except the highest opening above the roof and the entire system filled with water to the point of overflow above the roof. If the system is tested in sections, each opening shall be plugged except the highest opening of the section under test and each section shall be filled with water, but no section shall be tested with less than a ten-foot head of water. In testing successive sections, at least the upper ten feet of the next proceeding section shall be retested so that no joint or pipe in the building shall have been submitted to a test of less than a ten-foot head of water. The water shall be kept in the system or the portion under test for at least 15 minutes before inspection starts and the system shall be tight at all points.
(Ord. No. 64-2007, 7-24-2007; Ord. No. 132-2019, 11-5-2019)