§ 5-4 — Indoor pistol and firing ranges

Code of Ordinances of the City of Kenner, Louisiana (Codified through Ordinance No. 13,238, enacted September 18, 2026. (Supp. No. 15)) · Kenner Code of Ordinances § 5-4

Corpus is an independent public-information project, not the official City of Kenner website. Stable reference: corpuslaw.us/code/cc2e03ad-84ed-45c9-b856-8bc759e3ff08

Sec. 5-4. - Indoor pistol and firing ranges.

(1) General requirements. (a) Any gallery range license applicant within this jurisdiction must show intent to comply with these code requirements before a building permit will be granted, and must demonstrate compliance before occupancy in order to receive a license to operate. (b) The range is understood to include the entire space enclosed by the building structure in which the discharge of firearms may take place. (The space behind the shooters, however great, is included in the range and must comply.) (c) Compliance will be determined from the building plans provided for obtaining the building permit, and from such additional data as may be requested. (d) In recognition that special considerations are sometimes involved, the licensing authority may add further requirements as it sees fit. Furthermore, any of the following requirements may be waived or altered if sufficient reason can be shown. (e) The primary type of shooting activity that will be conducted must be established for the record. All other shooting activities that might be conducted must also be established. In case of conflict the most severe activity will govern compliance. (f) Except as provided in the section for special ranges the range must be of the fixed firing line type in which the shooters remain at one firing line and the targets are brought back and forth to the target line(s) mechanically. (g) Specialized terminology in this code shall be interpreted according to the glossary which follows it. All terminology not included in the glossary shall be interpreted according to Webster's Unabridged International Dictionary, current edition. (2) Special considerations. (a) The length must be sufficiently great that the shooters will never be closer than thirty-five (35) feet to the bullet trap; (as measured by the longest projection of the bullet trap upon the floor) and sufficient for proper door placement as defined later. (b) The width must be sufficient to provide three-foot minimum width shooting points for ranges with shooting separators and five-foot minimum width points for those without separators. (There is no maximum width.) (c) The height at the firing line must be eight-foot minimum from floor to ceiling. (The purpose of this requirement is to discourage attempts to build ranges in spaces that cannot be responsibly equipped and supervised.) There shall be no downrange doors into occupied areas. Downrange shall be understood to be from a point three (3) feet behind the firing line to the bullet trap. If there is more than one (1) firing line the most distant one from the trap governs. There may be downrange doors into unoccupied areas if human egress is not possible. (This provides for electrical and plumbing cabinets, etc. Of course, it is prudent that these be protected.) There may be downrange doors into normally unoccupied areas that permit human egress providing that they are equipped with electrical safety devices that will provide an alarm to the firing line if the area is occupied and that will provide an alarm in the area if any of the ordinary range functions are commenced (turning on target lights, target systems, etc.). (This makes possible the use of storage areas that can only be reached through the range.) (d) Windows are governed by the following requirements (whether noise attenuating, shatterproof or bulletproof is determined by use of the range and is not the purview of this Code): 1. There shall be no windows into contiguous areas not controlled by the owner. 2. Downrange windows shall be governed as stipulated for downrange doors. (3) Ballistic security. (a) Weapons. It must be established for the record what weapons and ammunition will be used. Handguns shall be of reputable manufacturers and ammunition factory loaded. (b) Secure area. If the range is situated so that an escaped bullet cannot fall into or pass through occupiable areas there is no ballistic security requirement for the structure separating the range from such areas. The range design manuals of the regular military services shall govern the amount of secure area required in such cases. (c) Earth separation. Earth separation of three (3) feet or greater is sufficient to eliminate any ballistical security requirement of the structure in that particular direction. (d) Critical zones. Critical zones must be penetration proof for the heaviest ammunition that might be used on the range fired point blank into it (at ninety (90) degrees to the surface). 1. The horizontal critical zone is any surface that a shooter in any shooting point can hit from forty-five (45) degrees downrange on either side to twenty (20) degrees behind him on either side. 2. The vertical critical zone is any surface that a shooter in any shooting point can hit when facing downrange from straight down to straight up. (4) Wall construction. (a) Walls in the critical zone may be standard grade concrete blocks with their cavities filled with crushed rock of three-quarter-inch or smaller screen. Sand is not acceptable. Concrete of any density is acceptable as the fill. Other suitable constructions are: Four (4) inches of reinforced concrete, one-quarter inch of mild steel over an appropriate supporting surface, single layer of face brick. (b) Walls in the secondary zone may be standard grade concrete blocks without filled cavities. Other suitable constructions are: Three (3) inches of reinforced concrete, one-eighth inch of mild steel over an appropriate supporting surface. Wood planking, plywood and gypsum board maybe used in sufficient thicknesses to be ballistically equivalent but may result in excessive maintenance. (c) Wall baffles may be used in lieu of the above constructions for either zone. When used there is no ballistical security requirement of the walls. When used the following requirements must be met: 1. The baffles must shelter the wall so that misdirected shots from all shooting points are interrupted by the baffles before striking the wall. 2. The baffles must be so angled that no bullet may hit any baffle at a greater angle than forty-five (45) degrees. 3. The baffle steel must be of sufficient thickness that it is not dented by the heaviest ammunition if left bare. Or if covered with a wood surface it must be of sufficient thickness that even if dented its structural integrity is maintained. (d) Wall construction in residential areas as nonconforming: 1. Side walls shall be protected by a one-eighth-inch steel plate or lengthening of shooting separators to guard against misaimed projectiles from striking side walls. 2. Rear wall shall be protected by a one-eighth-inch steel plate to guard against fail of venetian or escalator system. (5) Floor construction. (a) In the critical zone floors shall be reinforced concrete of four-inch minimum thickness. In new construction the floor shall be graded to a downrange floor drain. (b) Exposed slab ceiling or roof must be governed by the same requirements as floors. If the bottom surface of the slab is not smooth the following shall govern. (c) Ceiling baffles must be provided to protect any item that may interrupt the downrange travel of bullets from an angle of forty-five (45) degrees to the vertical ahead of the shooter to the bullet trap. If the ceiling baffles protect the entire overhead area (each baffle starting its protection where the previous one left off) then there is no ballistical security requirement for the ceiling or roof above. The baffle construction must otherwise comply with the requirements for wall baffles. (6) Ceiling system. (a) If the range has a smooth concrete slab ceiling without any beams or protrusions, and no ducts, conduits, etc. need be run through the area, then simple redirective coves for the lights may be adequate. This is rarely the case. In most cases a conventional air space principle safety ceiling system is the best choice. (b) If the owner is doing all of his own work in converting the building to a range, he can fabricate his ceiling system less expensively than buying it. However more and more facilities are being put in by businessmen who are more concerned about getting into profitable operation with a minimum of nuisance than minor savings. In those cases our prefabricated ceiling members are real bargains. In a typical situation sixteen-foot long horizontal members will start at the firing line and extend downrange. This will be followed by four (4) air-space principle baffles and a final redirective cove just ahead of the trap. (c) Columns, pilasters, exposed piping and other protuberances downrange shall be protected from damage and prevented from causing ricochets. Angled steel plates may be used for all protuberances. The requirements for wall baffles shall govern. Pilasters may be faired to the wall with concrete so that the angle to the wall of the surface of the fairing concrete is thirty (30) degrees or less. (7) Plumbing. (a) In new construction there shall be a floor drain downrange and a hose bib in the range area. (b) In existing construction the floor drain may be waived if a slop sink is located within fifty (50) feet of the range. (c) Wood facings are not allowed for protection of surface unless they are separated from any hard surface (steel or masonry) behind them by an air space of at least one (1) inch. (8) Noise attenuation. (a) The maximum noise that may escape the range into areas not controlled by the owner is 40 db. (b) Sufficient acoustical treatment shall be provided to reduce the sound level from magnum ammunition by 10 db minimum. (c) Acoustical materials subject to spraying (i.e., the sprayed on type) shall not be used. (9) Ventilation. (a) The permissible exposure to toxic lead products of gunfire shall be governed by current U.S. Department of Labor standards. (b) There must be positive flow of air past the shooter in a downrange direction, with all exhaust downrange. (c) The minimum operating temperature shall be fifty (50) degrees Fahrenheit and the maximum ninety (90) degrees Fahrenheit. (10) Lighting. (a) There shall be general illumination in the firing line area of 30 MFC as measured at the floor. The minimum downrange general illumination shall be 10 MFC at the floor. (b) At least one (1) circuit must be on dual switches so that it may be turned on from the door. (c) There shall be emergency lighting that will automatically illuminate if the lights fail. This must be on standby power. (11) Bullet traps. (a) Locally fabricated plate-and-pit backstops are the chief cause of equipment induced range accidents. Modern bullet traps involve complex considerations that are beyond the capability of the authority to evaluate even if believed to be adequate by the local fabricator. Therefore, the bullet trap shall be from an established manufacturer of range equipment with five (5) years or more successful experience, and for which evidence is submitted of successful applications in other ranges of the same general type. (b) The bullet trap shall be an area type; a trap that covers the entire butts end of the range. (c) The butts end of the range is defined as the total space between the two (2) side walls and from the floor to the sheltered area created by the ceiling system; or in the case of a flat slab roof, up to that roof. (12) Shooting separators. (a) All ranges shall have physical separation between the shooting points unless positive reasons are established to show that this cannot be provided. (Dual use of the area is not an acceptable reason unless it can be shown that there is no other way the secondary activity can be conducted.) (b) The separators shall be structurally sound and functional for the type of range. (c) The separators shall be so designed that any misdirected shot sixty (60) degrees to the right or left of a shooter that hits any portion of the stall will be deflected downrange without further interruption to its line of travel that may cause ricochet back towards the shooters. (13) Site selection. The range must not constitute a nuisance nor a hazard to its contiguous areas. It must be established that the zoning or natural configurations of the contiguous areas prevents them from being occupied by sensitive areas.

(Ord. No. 8165, 9-2-99)

Ask a question about Kenner law

Corpus searches the Kenner sections it holds and shows the ones that match, with their citations. Free, no sign-in.