§ 8-2 — Minimum fire standards for high-rise buildings

Code of Ordinances of the City of Kenner, Louisiana (Codified through Ordinance No. 13,238, enacted September 18, 2026. (Supp. No. 15)) · Kenner Code of Ordinances § 8-2

Corpus is an independent public-information project, not the official City of Kenner website. Stable reference: corpuslaw.us/code/701bb75c-4258-49f5-946d-32171eafd3b7

Sec. 8-2. - Minimum fire standards for high-rise buildings.

(A) Early warning smoke detection devices, alarm systems and automatic sprinkler systems are mandatory requirements of all high-rise structures in the City of Kenner. (B) A "high-rise building" is a building which exceeds thirty-five (35) feet in height. This includes roof structures, such as, mechanical equipment rooms and penthouses. The height shall be measured from the first floor slab elevation to the top of the roof slab or deck and does not include elevator or stair or other unoccupied spaces. (C) All buildings above thirty-five (35) feet will provide the following: (1) Automatic sprinkler systems. An approved complete sprinkler system shall be provided throughout the building. The sprinkler system shall be designed using the perimeters set forth in the National Fire Code Protection Association codes, N.F.P.A. 13, and sprinkler alarm systems to be of a supervisory type, N.F.P.A. 72-B, C or D. (a) Shut-off valves and water flow devices shall be provided at the riser connection on each floor. In addition to the actuating alarm on all floors upon which the water flow is detected, such valves shall be supervised by a central station. The sprinkler riser may be combined with the fire department stand-pipe riser. (b) Automatic fire sprinklers may be omitted in the following rooms or areas when such rooms or areas are protected with an approved automatic fire detection system which will respond to visible or invisible particles or combustion: 1. Generator and transformer rooms. 2. Any room where the application of water, or flame and water, may constitute a serious life or fire hazard. 3. Communication equipment areas under the exclusive control of the public utility provided: a. The equipment areas are separated from the remainder of the building by construction equivalent to one-hour fire-resistive wall and two-hour fire-resistive floor-ceiling assemblies. b. Such areas are used exclusively for such equipment. c. When approved by the department of regulatory inspection and fire department, any other area or room where sprinklers are considered undesirable because of the nature of the contents. d. No telephonic recording system or other alarm notifying equipment will be permitted to be directly transmitted to or stored at the City of Kenner Fire Department fire alarm dispatching office. (2) Smoke detection system. An approved complete smoke detection system shall be provided throughout the building. This system shall be designed in the perimeters set forth in the National Fire Protection Association Code 73E, and the detection alarm system is to be of a supervisory type. In addition, if not already specified, at least one approved suitable detector in every mechanical equipment room, electrical transformer, telephone, elevator machinery, or similar room shall be provided. In the main return and exhaust air plenum of each air conditioning system serving more than one (1) story, and located in a serviceable area downstream of the last duct outlet. In each connection to a vertical duct or riser serving two (2) or more stories from return air duct or plenum of heating ventilators and air conditioning system. The actuation of any detector required by this section shall operate and place into operation all equipment necessary to prevent recirculation of smoke. Smoke detector alarm systems shall be of a supervisory type. Enunciator equipment shall be provided near the first floor entry level of the structure, or when provided with fire control center, shall be located in an area specified by the fire department. Fully sprinklered office and retail occupancies are excluded from the requirements of this subsection (smoke detection system.) (3) H.V.A.C. systems shall be installed in any building applicable to this ordinance in accord with N.F.P.A. 90A. (a) All vertical penetration shall be held to a minimum. All vertical penetrations, i.e., stair enclosures, laundry shoots, pipe shafts, telephone shafts, etc., shall be vented by natural gravity smoke relief venting 1/150 minimum opening ratio vent to area. (4) Stairs. All required stairs shall be constructed in accordance with the design known as "smoke-proof enclosure." (a) A smoke-proof enclosure shall consist of a vestibule and continuous stairway enclosed from the highest point to the lowest point by walls of two-hour resistive construction. (b) Stairs in the smoke-proof enclosure shall be of noncombustible construction. (c) A smoke-proof enclosure shall exit into an exit passage leading to a public way. The exit passage shall be without other openings and shall have walls, floors and ceilings of two-hour fire resistance. (d) A stairway in a smoke-proof enclosure shall not continue below the grade level unless an approved barrier is provided at the ground level to prevent persons from accidentally continuing into the basement. (e) Access to the stairway shall be by way of an open, exterior balcony of noncombustible materials. (f) Smoke-proof enclosures by natural ventilation. Doors to the stairways shall be labeled and shall be a minimum of one and one-half-hour fire-resistance rating and have closing devices. The exit doors into the stair shaft shall close automatically when released, by activation of a detector. The door-holding device shall be of an approved type which will release the doors so that they will close in the event of power failure. Enclosures shall be vented by natural ventilation. A gravity smoke relief venting or 1/150 minimum opening ratio to area. (g) All smoke-proof enclosures shall be identified as such and marked as a fire escape. (h) This section shall not apply to any structure which has exterior (i.e. unenclosed) circulation systems used for either the primary of secondary means of ingress and egress. (i) Fully sprinklered office and retail occupancies are excluded from the requirements of this subsection (stairs.) (5) Standby power and light. (a) On-site generated power. A permanently installed standby generation system conforming to N.F.P.A. 70 shall be provided. The system shall be equipped with suitable means for automatically starting the generator set upon failure of the normal electrical service and for automatic transfer and operation of electrical functions. System supervision device with manual start and transfer features shall be provided at the central control station. (b) Standby power loads. The following loads are classified as standby power loads. Transition time from the instant of failure of the normal power source to the generator source shall not exceed sixty (60) seconds. The standby power lead shall be sized to supply the following: 1. Elevators. 2. Mechanical air handling systems required to be operated during an emergency. 3. Fire pumps. (c) Emergency power loads. The transition time from the instant of failure of normal power source to the generating source shall not exceed ten (10) seconds unless otherwise specifically noted. The following loads are classified as emergency power loads: 1. Voice alarm system. 2. Voice communication systems. 3. Fire alarm systems. 4. Fire detection systems. 5. Elevator car lighting. 6. Escape route lighting and exit sign illumination which shall operate within one (1) second. (d) All vertical runs of alarm and communication systems shall be installed in a two-hour fire-resistive shaft, provided for that purpose, with protected openings. These enclosures shall be aligned vertically and be accessible from common or public areas. (6) Elevators. (a) All elevators and elevator lobbies shall comply with the following: Note: A bank of elevators is a group of elevators or a single elevator controlled by a common operating system; that is, all elevators which respond to a single call button constitute a bank of elevators. There is no limit on the number of cars which may be in a bank or group but there may be no more than four (4) bars within a common hallway. 1. Except for the main entrance level, all elevators on all floors shall open into elevator lobbies which are separated from the remainder of the building by a vestibule. Doors to the vestibule shall be labeled and listed and shall have a minimum of one-hour fire-resistive rating and shall have closing devices, shall have wire glass, one-half inch thick, not to exceed one hundred (100) square inches, with neither dimension exceeding twelve (12) inches. The door shall be provided with a drop sill or other provision to minimize air leakage. Exit doors into the vestibule shall close automatically when released by activation of the detector. The door-holding device shall be of an approved type, which will release the door so that door will close in the event of power failure. 2. Each elevator lobby shall be provided with an approved smoke detector located on the lobby ceiling when any alarm, emergency signal system is activated. When the detector is activated, elevator doors shall not open and all cars serving that lobby are to return to the main floor and be under manual control only. The smoke detector is to operate before the optical density reaches 0.03 per foot. The detector may serve to close the lobby doors. At no time are lobby doors to be wedged or held in an open position. 3. A permanent sign shall be installed in each elevator cab adjacent to the floor status indicator and at each elevator call station on each floor reading "IN CASE OF FIRE, DO NOT USE ELEVATOR—USE EXIT STAIR," or similar verbiage approved by the department of regulator inspection/fire department. 4. Elevator hoistways shall not be vented through an elevator machine room. Cable slots entering the machine room shall be sleeved beneath the machine room floor and extend to not less than twelve (12) inches below the shaft vent to inhibit the passage of smoke into the machine room. 5. At least one (1) elevator car serving all floors shall have a minimum inside car platform of four (4) feet three (3) inches deep by six (6) feet eight (8) inches wide within a minimum clear opening width of forty-two (42) inches; unless otherwise designed and approved to provide equivalent utility to accommodate an ambulance stretcher having a minimum size of twenty-two (22) inches by seventy-eight (78) inches in its horizontal position. This elevator shall be identified. This elevator shall be located in an independent shaft and operate on normal and emergency power. 6. Keys are to be provided at each elevator location and in the central fire control room for all elevators in the building. All elevators are to be provided with two-way communication systems connected to an approved emergency service which operates on a twenty-four-hour basis. All elevators are to be equipped with fire department control mechanisms. (D) In addition to the aforementioned requirements, structures which are above seventy-five (75) feet are also required to provide the following: (1) Alarm and communication systems. The alarm and communications system shall be designed and installed such that damage to any terminal unit or speaker will not render more than one (1) zone of the system inoperative. The voice alarm and public address system may be a combined system. When approved, the fire department communications system may be combined with the voice alarm system and the public address system. Three (3) communication systems shall be provided as follows: (a) Voice alarm system. 1. The operation of any smoke detector, required by this section, sprinkler, waterflow device or manual fire alarm system, shall automatically activate a voice alarm system. The voice alarm system shall provide a pre-determined message on a selective basis to the area where the alarm originated. 2. The voice alarm shall provide information and give direction to the occupants. 3. The central control station shall contain controls for the voice alarm system so that a selective or general voice alarm may be manually initiated. 4. The systems shall be continuously electrically supervised against component failure of the audiopath including amplifiers, speaker wiring, switches and electrical contacts and shall detect opens and shorts which might impair the function of the system. 5. Activation of the system shall automatically sound an alert signal to the desired areas followed by voice instructions giving appropriate information. 6. The alarm shall be designed to be heard clearly by all occupants within the building or designated portions thereof as is required for the public address system. (b) Public address system. A public address communication system designed to be clearly heard by all occupants of the building shall operate from the central control station. It shall be established on a selective or general basis to the following terminal area: 1. Elevators. 2. Elevator lobbies. 3. Corridors. 4. Exit stairways. 5. Rooms and tenant spaces exceeding one thousand (1,000) square feet in area. 6. Dwelling units in apartment houses. 7. Hotel guest rooms and suites. (c) Fire department communication system. A two-way fire department communication system shall be provided for fire department use. It shall operate between the central control station and every elevator, elevator lobby, entry to every enclosed exit stairway and in corridors. (2) Central fire control station. (a) A central control station for fire department operations shall be provided in location approved by the fire department, shall contain: 1. The voice alarm and public address system panels. 2. The fire department communications panel. 3. Fire detection and alarm system annunciator panels. 4. Status indicators showing location of elevators in the hoistways and switches to selectively turn on or off power to elevators. 5. Status indicators and controls for air handling systems. 6. Controls for unlocking all stairway doors simultaneously. 7. Sprinkler valve and waterflow detector display panels. 8. Emergency power, light and emergency system controls and status indicators. 9. A telephone for fire department use with controlled access to the public telephone system. (E) The following provisions shall apply to all structures above thirty-five (35) feet: (1) The city shall provide for periodic inspection of the construction to determine that the installation performed is in accordance with plans and specifications approved by the City of Kenner Department of Regulatory Inspections and the Kenner Fire Department. These inspections shall be performed by persons authorized to prepare plans and specifications or persons authorized by the authority to make inspections under applicable state, parish or city ordinance. (2) This section does not restrict or eliminate federal, state, parish or other city requirements. If such are in conflict with all or any part of this section, the more stringent requirement will be applicable. (3) Any person, firm, corporation, etc., who does not comply with the provisions of this section shall be found in violation of this section. A violation shall carry a fine of two hundred dollars ($200.00) per day and each day constitutes a separate violation. The provisions of this section shall only apply to those structures which are constructed after the effective date of this section. (4) If any provision or item of this section or the application thereof is held invalid, such invalidity shall not affect other provisions, items or applications of this section which can be given effect without the invalid provisions, items or applications and to this end the provisions of this section are hereby declared severable. (5) Single-family dwellings are excluded from this section. (6) Any structure which is presently existing shall be required to conform to all provisions of Ordinance 1545; and, nothing herein shall prevent the fire department for the City of Kenner from enforcing same. (7) Unenclosed parking garages separated from a structure incorporating another occupancy are excluded from this section.

(Ord. No. 1545, 7-23-73; Ord. No. 2878, §§ 1—5, 2-19-81; Ord. No. 3025, §§ 1—5, 8-17-81)

Ask a question about Kenner law

Corpus searches the Kenner sections it holds and shows the ones that match, with their citations. Free, no sign-in.