§ 21-74 — Building sewer and connections
Code of Ordinances of the City of Lake Charles, Louisiana (Codified through Ordinance No. 20598, enacted August 5, 2026. (Supp. No. 21, Update 1)) · Lake Charles Code of Ordinances § 21-74
Corpus is an independent public-information project, not the official City of Lake Charles website. Stable reference: corpuslaw.us/code/477a3f21-a4cd-49de-8ad3-3bd0376c5a04
Sec. 21-74. - Building sewer and connections.
(a) Permit required. It is unlawful to uncover, make any connection with or opening into, use, alter or disturb any public sewer or appurtenance thereof without first obtaining a written permit from the plumbing inspector's department. (b) Classes of permits; application. There are two classes of building sewer permits: (1) For residential, commercial, minor industrial and institutional service; and (2) For service to establishments producing industrial wastes. In either case, the owner or his agent, shall make application on a special form furnished by the city. The permit application shall be supplemented by any plans, specifications or other information considered pertinent in the judgment of the plumbing inspector or director of public works. (c) Installation cost and expense to be borne by owner. All costs and expenses incident to the installation and connection of the building sewer shall be borne by the owner. The owner shall indemnify the city from any loss or damage that may directly or indirectly be occasioned by the installation of the building sewer. (d) Separate building sewer required. A separate and independent building sewer shall be provided for every building except where one building stands at the rear of another on an interior lot, and no private sewer is available or can be constructed to the rear building and the whole considered as one building sewer. (e) Use of old building sewers. Old building sewers may be used in connection with new buildings only when they are found, on examination and test by the plumbing inspector, to meet all requirements of this division. (f) Materials and specifications generally. The building sewer shall be cast-iron soil pipe, ASTM specification (A74-42) or equal; vitrified clay sewer pipe, ASTM specification (C13-447) or equal; or other suitable material approved by the city plumbing code. Joints shall be tight and waterproof. Cast-iron pipe with waterproof joints may be required by the plumbing inspector where the building sewer is exposed to damage by tree roots. If installed in filled or unstable ground, the building sewer shall be of cast-iron soil pipe, except that nonmetallic material may be accepted if laid on a suitable concrete bed or cradle as approved by the plumbing inspector. (g) Size and slope. The size and slope of the building sewer shall be subject to the approval of the city plumbing code. In general, the building sewer shall be the same size as the service branch but in no event less than four inches in diameter. The slope of the building sewer shall in no event be less than ⅛ inch per foot for four-inch pipe. (h) Elevation laying of sewer; changes in direction. Whenever possible the building sewer shall be brought to the building at an elevation below the basement floor. No building sewer shall be laid parallel to and within three feet of any bearing wall which might thereby be weakened. The depth shall be sufficient to afford protection from frost. The building sewer shall be laid at uniform grade and in straight alignment insofar as possible. Changes in direction shall be made only with properly curved pipe and fittings. (i) Procedure where building drain too low. In all buildings in which any building drain is too low to permit gravity flow to the public sewer, sanitary sewage carried by such drain shall be lifted by approved artificial means and discharged to the building sewer. (j) Excavations generally; pipe laying and backfill. All excavations required for the installation of a building sewer shall be open trench work unless otherwise approved by the plumbing inspector. Pipe laying and backfill shall be performed in accordance with ASTM specification (C-12) latest revision, except that no backfill shall be placed until the work has been inspected. (k) Joints and connections. All joints and connections shall be made gas-tight and watertight. Cast-iron pipe joints shall be firmly packed with waterproof packing. No paint, varnish or other coatings shall be permitted on the jointing material until after the joint has been tested and approved. All joints in vitrified clay pipe or between VC pipe and cast-iron pipe shall be made with an approved bituminous jointing material or a compression joint meeting ASTM-C425 specifications. Where a hot-poured joint is used, the joint shall first be caulked with jute, hemp or similarly approved material. The bituminous material for hot-poured joints shall not soften sufficiently to destroy the effectiveness of the joint when subjected to a temperature of 160 degrees Fahrenheit nor be soluble in any of the wastes carried by the drainage system. (l) Connection of building sewer to public sewer generally. The building sewer shall be connected into the public sewer at the property line, if a service branch is available at a suitable location. Where no properly located service is available a neat hole may be cut into the public sewer and a suitable wye or tee saddle installed to receive the building sewer. The invert of the saddle shall be in the upper quadrant of the main line of the public sewer. A net workmanlike connection shall be made and the saddle made secure and watertight by encasement in concrete. (m) Notification of readiness for inspection; supervision of connections. The applicant for the building sewer permit shall notify the plumbing inspector when the building sewer is ready for inspection and connection to the public sewer. The connection shall be made under the supervision of the director of public works or his representative. (n) Guarding of excavations; restoration of streets, sidewalks, etc. All excavations for building sewer installation shall be adequately guarded with barricades and lights so as to protect the public from hazard. Streets, sidewalks, parkways and other public property disturbed in the course of the work shall be restored in a manner satisfactory to the city.
(Ord. No. 9414, § 1, 8-21-91; Ord. No. 15522, § 2, 8-4-10)
Ask a question about Lake Charles law
Corpus searches the Lake Charles sections it holds and shows the ones that match, with their citations. Free, no sign-in.
