For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 38-12 — Requirements for residential buildings

Code of Ordinances, City of Shreveport, Louisiana (Supp. No. 85, Update1: codified through Ordinance No.150, 2025 adopted December 9, 2025) · Shreveport City Code § 38-12

Corpus is an independent public-information project, not the official City of Shreveport website. Stable reference: corpuslaw.us/code/bf8334e4-a60f-4041-907b-87c483096641

Sec. 38-12. - Requirements for residential buildings.

No owner, party-in-interest or agent shall lease or sublease, or allow any person to occupy, any dwelling or dwelling unit designed or intended to be used for the purpose of residential living, sleeping, cooking or eating therein, or otherwise maintain any unoccupied dwelling or dwelling unit located within the corporate limits of the city which does not comply with the following requirements. All requirements of the following subsection shall be deemed to be the responsibility of the owner or party-in-interest: (1) Foundation. The building foundation system shall be maintained in a safe manner and be capable of supporting the load which normal use may cause to be placed thereon. (2) Exterior walls. Every exterior wall shall be free of holes, breaks, loose or rotting boards or timbers and any other condition which could potentially admit rain or dampness to the interior portions of the walls or to the occupied spaces of the building. All siding material shall be sufficiently maintained in good repair and be weather resistant and water tight. (3) Roofs. Roofs, gutters, downspouts and other appurtenances shall be structurally sound and maintained in a safe manner and have no defects which could potentially admit rain or cause dampness in the walls or interior portions of the building. (4) Means of egress. Every dwelling shall have safe, unobstructed means of egress and shall open from the inside. (5) Stairs, porches and appurtenances. Every inside and outside stair, porch and any appurtenance thereto shall be safe to use and be capable of supporting the load that normal use may cause to be placed thereon, and shall be maintained in sound condition and good repair. (6) Protective railings. Protective railings shall be required on any porch or other path of ingress or egress over 30 inches from ground level or on any steps containing four or more risers. (7) Windows and doors. Every window and/or exterior door shall be substantially weathertight, watertight and rodent-proof and shall be maintained in sound working condition and good repair. (8) Windows to be openable. Except as otherwise provided herein, every window required for light and ventilation for a habitable room that is designed to be opened shall be capable of being easily opened and secured in position by properly functioning window hardware. However, if multiple windows exist in the room, at least one window shall be unobstructed and capable of being easily opened and secured in position by properly functioning window hardware. (9) Hardware. Every exterior door shall be provided with proper hardware and maintained in good condition. (10) Protective treatment. All exterior wood surfaces, other than decay resistant woods, shall be free of holes, breaks or loose or rotting board or timber and any other condition which could potentially be protected from the environment and decay by painting or other protective covering or treatment. All siding shall be weather resistant and watertight. All masonry joints shall be sufficiently tuck pointed to ensure water and air tightness. (11) Accessory structures. Garages, storage buildings and other accessory structures shall be maintained in good repair and sound structural condition. (12) Structural supports. Every structural element of the dwelling shall be maintained structurally sound and demonstrate no evidence of deterioration which would render it incapable of carrying loads which normal use may cause to be placed thereon. (13) Interior. The interior of a structure, including but not limited to floors, walls, ceilings and other interior surfaces shall be maintained in good repair and structurally sound so as not to pose a threat to the health, safety or welfare of the occupants. (14) Ventilation. All areas in a structure shall be provided sufficient ventilation so as not to endanger health, safety or welfare of the occupants. (15) Plumbing facilities. Each dwelling unit shall include its own plumbing facility which shall be maintained in proper operating condition. a. Each dwelling unit shall contain within its walls a room separate from other habitable areas, which provides a toilet supplied with plumbing fixtures and piping to accommodate cold running water and which affords privacy. b. Each dwelling unit shall contain a lavatory, a bathtub or shower, and a toilet which shall be maintained in proper operating condition and supplied with plumbing fixtures and piping to accommodate hot and/or cold running water. c. A lavatory shall be placed in the same room as the toilet or located in another room in close proximity to the door leading directly into the room in which the toilet is located. The lavatory shall be supplied with plumbing fixtures and piping to accommodate both hot and cold running water. d. Kitchen sink. Each dwelling unit shall contain a kitchen sink apart from the lavatory which sink shall be supplied with plumbing fixtures and piping to accommodate both hot and cold running water. (16) Plumbing fixtures. a. All plumbing fixtures shall be maintained in a safe and usable condition. b. Water supply lines, vents, and drains shall be maintained in working order and shall be kept free from obstructions, leaks, and defects and shall be capable of performing the function for which they are designed. (17) Water and sewer system. a. Properly functioning water and sewer service lines shall be established and maintained at all times that the dwelling unit is occupied. b. Each lavatory, bathtub or shower, drinking fountain, water closet, or other plumbing facility shall be properly connected to a public water system at all times that the dwelling unit is occupied. c. Water heating facilities shall be installed in a safe manner and properly connected to water lines to the fixtures required to be supplied with the hot water at all times that the dwelling unit is occupied. (18) Heating equipment. Each dwelling unit shall be supplied with sufficient heat or heating equipment at all times that the dwelling unit is occupied. (19) Electrical facilities. a. All electrical facilities shall be installed and maintained in a safe manner which complies with state and federal codes in effect when the structure was built or substantially remodeled. b. All electrical outlets shall be covered by protective plates or covers.

(Ord. No. 138, 2019, 10-22-19)

Ask a question about Shreveport law

Corpus searches the Shreveport sections it holds and shows the ones that match, with their citations. Free, no sign-in.