For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4.3 — COMMERCIAL DISTRICTS

Code of Ordinances, City of Shreveport, Louisiana (Supp. No. 85, Update1: codified through Ordinance No.150, 2025 adopted December 9, 2025) · Shreveport Unified Development Code § 4.3

Corpus is an independent public-information project, not the official City of Shreveport website. Stable reference: corpuslaw.us/code/ff7070b4-fb11-49e5-8eb7-64e71cf23343

4.3 - COMMERCIAL DISTRICTS

A. Purpose Statements 1. C-1 Neighborhood Commercial Zoning District The C-1 Neighborhood Commercial District is intended to accommodate local non-residential uses that predominantly serve the needs of the nearby residential neighborhoods and are similar in character of the surrounding residential neighborhood. Residential dwelling units are allowed above the ground floor. 2. C-2 Corridor Commercial Zoning District The C-2 Corridor Commercial Zoning District is intended to accommodate the commercial corridors of the City of Shreveport. The C-2 District addresses primarily auto-oriented retail, both individual businesses and retail centers, with the intent of improving the pedestrian environment along the corridor. Mixed-use development is encouraged with residential dwelling units allowed above the ground floor. 3. C-3 General Commercial Zoning District The purpose of the C-3 General Commercial Zoning District is to accommodate regional commercial centers. The C-3 District provides for medium- and large-scale development that may generate a sizeable amount of traffic and typically requires significant off-street parking. Higher density residential uses are also allowed to facilitate mixed-use development where appropriate. 4. C-4 Heavy Commercial Zoning District The C-4 Heavy Commercial Zoning District is intended for areas of more intense commercial use, including uses related to motor vehicles and those that may require outdoor storage. Because of the impacts from more intensive commercial uses, the district regulations ensure that setbacks, buffering, and site development controls are in place to mitigate negative impacts on neighboring uses. 5. C-UC Urban Corridor Commercial Zoning District The C-UC Urban Corridor Commercial Zoning District is intended for corridor development that originally developed as mixed-use, traditional business districts. The C-UC District is intended to foster the continued development and redevelopment of these corridors in that established urban character and offer flexibility to developers and property owners in creating a mix of commercial, office, and residential spaces. 6. C-UV Urban Village Commercial Zoning District The C-UV Urban Village Commercial Zoning District is intended for large developments characterized by a mix of commercial uses and higher density residential, creating a coordinated mixed-use environment that is pedestrian-friendly and incorporates public space within the overall design. B. Uses Article 5 lists permitted and special principal uses and temporary uses for the commercial districts. C. Dimensional Standards 1. Table 4-3: Commercial Districts Dimensional Standards establishes the dimensional standards for the commercial districts. These regulations apply to all uses within each district unless a different standard is listed for a specific use. Section 4.3.D has additional design standards that apply to development within the districts. 2. In the C-1 District commercial development is limited to the maximum gross floor area indicated in Table 4-3. Development may exceed this gross floor area if during site plan review the Executive Director finds that the development meets the following standards: a. The development maintains the privacy of adjacent residential lots through techniques such as decreased height, context sensitive landscape and screening, building massing design to mitigate noise, and increased setbacks from residential lots that mitigate noise and line of sight. b. Building design elements incorporate pedestrian-scale features such as awnings and canopies, sloped roofs, and residential-type design features. c. Site illumination is designed and installed to minimize adverse impact on adjacent residential lots. d. The site circulation system provides adequate and safe access to the site for any motor vehicles as well as alternate modes of transportation, including pedestrians and bicyclists, and minimizes potentially dangerous traffic movements. 3. Certain standards within the C-UC District are applied as follows: a. Maximum lot area is only applicable to new lots created through subdivision or any other manner after the effective date of this Code. b. Any residential structures existing in the district as of the effective date of this Code that exceed the required build-to zones are deemed conforming with the limitation that the setback may not be further increased in excess of the required build-to zone. When the lot is redeveloped and the principal structure is torn down, new development must conform to the requirements of the district. c. A waiver of setback requirements within the C-UC District may be considered to increase the district's build-to-zone provided the increase is no greater than the front or side setbacks for existing structures on adjacent lots on the same street frontage. The waiver shall not, in the opinion of the Executive Director, have an adverse effect on the neighborhood or general welfare of the area. TABLE 4-3: COMMERCIAL DISTRICTS DIMENSIONAL STANDARDS C-1 | C-2 | C-3 | C-4 BULK Minimum Lot Area | None | None | 10,000 sf | 10,000 sf Minimum Lot Width | None | None | 80' | 60' Maximum Gross Floor Area for Retail Use | 10,000 sf unless meeting the standards of Section 4.3.C.2 | None | None | None Minimum Building Height | None | 14' | 18' | None Maximum Building Height | 35' | 40' | 50' | 50' SETBACKS Minimum Front Setback | None | None | 20' | 20' Minimum Interior Side Setback | None, unless abutting residential district then 5' | None, unless abutting residential district then 10' | 10', unless abutting residential district then 20' | 10', unless abutting residential district then 20' Minimum Corner Side Setback | None | None | 20' | 20' Minimum Rear Setback | None, unless abutting residential district then 15' | None, unless abutting residential district then 15' | 10', unless abutting residential district then 20' | 10', unless abutting residential district then 20' C-UC DISTRICT Residential Use | Non-Residential Use BULK Minimum Lot Area | SF-D: 4,500 sf SF-A & 2F: 6,000 sf TH: 1,500 sf/du MF: 700 sf/du | None Maximum Lot Area | SF-D: 7,500 sf SF-A & 2F: 10,000 sf TH & MF: None | None Minimum Lot Width | SF-D: 45' SF-A & 2F: 60' TH: 15'/du MF: 80' | None Minimum Building Height | None | 14' Maximum Building Height | 40' | 40' SETBACKS Minimum Front Setback | SF-D, SF-A, & 2F: Build-to zone of 0' to 15' TH & MF: Build-to zone of 0' to 10' | Build-to zone of 0' to 10' Minimum Interior Side Setback | SF-D, SF-A, & 2F: 5' TH & MF: 10' | None, unless abutting residential district then 10' Minimum Corner Side Setback | SF-D, SF-A, & 2F: Build-to zone of 0' to 15' TH & MF: Build-to zone of 0' to 10' | Build-to zone of 0' to 10' Minimum Rear Setback | 15' | None, unless abutting residential district then 15' C-UV DISTRICT Development Site | Residential Use Site | Non-Residential Use Site BULK Minimum Lot Area | 10 acres | SF-D: 3,000 sf SF-A & 2F: 6,000 sf TH: 1,500 sf/du MF: 700 sf/du | None Minimum Lot Width | 300' | SF-D: 30' SF-A & 2F: 60' TH: 15'/du MF: 80' | None Minimum Building Height | — | — | 14' Maximum Building Height | — | SF-D, SF-A, 2F: 35' TH: 40' MF: 45' | 50' Minimum Open Space | 25% | — | — Maximum Impervious Surface | — | SF-D, SF-A, 2F, TH: 70% Minimum Front Setback | 25' | SF-D, SF-A, 2F: 20' TH & MF: Build-to zone of 0' to 20' | Perimeter streets: Build-to zone of 0' to 20' Internal streets: Build-to zone of 0' to 10' Minimum Interior Side Setback | 25' | SF-D, SF-A, 2F: 5' TH, MF: 10' | None, unless abutting residential use then 10' Minimum Corner Side Setback | 25' | SF-D, SF-A, 2F: 10' TH & MF: Build-to zone of 0' to 20' | Build-to zone of 0' to 10' Minimum Rear Setback | 35' | 15' | None, unless abutting residential use then 15' D. Commercial Design Standards 1. The following design standards apply to new construction, substantial repair or rehabilitation meant to remedy damage or deterioration of the exterior façade of an existing structure, and additions to an existing structure. However, only those standards that relate to the specific repair, rehabilitation, or addition apply. These standards do not apply to interior remodeling. When residential dwellings are allowed, those are subject to the applicable use standards of Article 6 of this Ordinance. Table 4-4: Commercial Design Standards indicates the applicability of building design standards to the commercial districts. In the C-UV District, any commercial design standards that apply along a public right-of-way are also applicable along any roadways internal to the site. A "•" indicates that the standard is applicable in the district indicated. The absence of a "•" indicates that the standard is not applicable. Click this link to download a PDF version of Table 4-4. TABLE 4-4: COMMERCIAL DESIGN STANDARDS C-1 | C-2 | C-3 | C-4 | C-UC | C-UV Facade and Fenestration Design All building facades that abut a public right-of-way, excluding alleys, must include a repeating pattern with no less than two of the following elements: color change, texture change, material module change, or a wall articulation change of no less than two feet in depth, such as a reveal, pilaster, or projecting rib. All elements must repeat at intervals of no more than 40 feet. | • | • | • | • | • | • Roof Design Rooflines over 100 linear feet in building length are encouraged to be variegated, and incorporate a major focal point feature, such as a dormer, gable, or projected wall feature. An element of variegation on the roofline must occur at intervals of no more than 75 feet. | • | • | • | • | • Parapet walls must feature three-dimensional cornice treatments or other shadow-creating details along their tops. | • | • | • | • Green roof, blue roof, and white roof designs are encouraged. | • | • | • | • | • | • Solar panels or white roofs intended to radiate absorbed or non-reflected solar energy and reduce heat transfer to the building are encouraged. | • | • | • | • | • | • Retail Center Siting The site shall be designed so that there is safe pedestrian access to the center from the public right-of-way and safe pedestrian circulation within the development. If there is no existing sidewalk network on any adjacent properties within the public right-of-way, or if there is not an approved corridor/thoroughfare plan showing a proposed sidewalk network, an exception may be granted to this requirement. | • | • | • | • | • Parking lots must be designed to provide safe designated walkways for pedestrians. Walkways must connect building entrances with parking areas and with public sidewalks along adjacent streets. | • | • | • | • | • A cohesive character is required through the use of coordinated hardscape treatment (special paving materials, lighting, street furniture, etc.) and landscaping. | • | • Outlot buildings must include showcase windows and entrances oriented toward both the street and the interior parking lot. | • | • If outlot buildings are part of a multi-tenant retail center, outlot buildings must define the street frontage by placement within zero feet to 25 feet of the lot line. Outlot buildings may be placed within a required setback to comply with this standard. | • | • A street presence for a mixed-use retail center must be created by locating part of the center or outlot buildings within zero feet to 25 feet of the lot line for at least 30% of the frontage. The center or outlot buildings may be placed within a required setback to comply with this standard. | • | • FIGURE 4-1: COMMERCIAL DESIGN STANDARDS [image omitted; see the official code] FIGURE 4-2: C-UV SITE DESIGN STANDARDS [image omitted; see the official code] 2. In order to meet the required percentage of open space required in the C-UV District, the following types of open space are permitted and must be indicated on plan submittals. a. Greens. A green where open space is available for unstructured recreation. Its landscaping consists of grassy areas and trees. b. Parks. A park must be a minimum of 5,000 square feet in size. c. Plaza/Square. A plaza or square that is improved by landscaping and hardscaping, and surrounded by buildings or streets along at least 50% of its perimeter. d. Drainage Control Facilities. These include detention or retention ponds, which are usable by the public for recreational purposes. 3. The following building materials are limited on any facade facing a public right-of-way, excluding alleys, or any facade that abuts a lot in residential use. However, such materials may be used as decorative or detail elements for up to 40% of the facade, or as part of the exterior construction that is not used as a surface finish material. a. Plain concrete block b. Corrugated metal c. Aluminum, steel, or other metal sidings d. Exposed aggregate (rough finish) concrete wall panels e. T-111 composite plywood siding f. Plastic g. Vinyl

(Ord. No. 76, 2017, § 8, 9-12-17; Ord. No. 62, 2018, §§ 3, 4, 8-14-18; Ord. No. 6, 2019, § 3(Exh. A.1), 2-12-19; Ord. No. 191, 2019, § 2, 1-14-20; Ord. No. 2, 2020, § 2(Exh. B), 1-28-20; Ord. No. 114, 2020, § 3, 9-8-20; Ord. No. 95, 2021, § 1, 7-13-21; Ord. No. 182, 2023, § 1, 1-9-24)

Ask a question about Shreveport law

Corpus searches the Shreveport sections it holds and shows the ones that match, with their citations. Free, no sign-in.