For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 27-181 — General development standards

Code of Ordinances of the City of Brockton, Massachusetts (Codified through Ordinance No. 07-31-2025(2), approved July 31, 2025 (Supp. No. 28)) · Brockton Code of Ordinances § 27-181

Corpus is an independent public-information project, not the official City of Brockton website. Stable reference: corpuslaw.us/code/7273e543-09d9-4635-89b8-7bb4c8376bee

Sec. 27-181. - General development standards.

(a) Development standards in the MCMOD are applicable to all multi-family development with more than eight (8) units or mixed-use development of more than twenty-five thousand (25,000) square feet within the MCMOD. These standards are components of the site plan review process in section 27-183, site plan review. (b) Site design. (1) Connections. Sidewalks shall provide a direct connection among building entrances, the public sidewalk, bicycle storage, and parking. (2) Vehicular access. Where feasible, curb cuts shall be minimized, and shared driveways encouraged. (3) Open space. Open space shall be of an appropriate size as to be usable by the building's tenants for passive recreation and small gatherings. The space shall be accessible to tenants twenty-four (24) hours a day, seven (7) days of the week. A portion of the space may be impermeable. (4) Screening for parking. Surface parking adjacent to a public sidewalk shall be screened by a landscaped buffer of sufficient width to allow the healthy establishment of trees, shrubs, and perennials, but no less than six (6) feet. The buffer may include a fence or wall of no more than three (3) feet in height unless there is a significant grade change between the parking and the sidewalk. (5) Parking materials. The parking surface may be concrete, asphalt, decomposed granite, bricks, or pavers, including pervious materials but not including grass or soil not contained within a paver or other structure. (6) Plantings. Plantings shall include species that are native or adapted to the region. Plants on the Massachusetts Prohibited Plant List, as may be amended, shall be prohibited. (7) Lighting. Light levels shall meet or exceed the minimum design guidelines defined by the Illuminating Engineering Society of North America (IESNA) and shall provide illumination necessary for safety and convenience while preventing glare and overspill onto adjoining properties and reducing the amount of skyglow. (8) Mechanicals. Mechanical equipment at ground level shall be screened by a combination of fencing and plantings. Rooftop mechanical equipment shall be screened if visible from a public right-of-way. (9) Dumpsters. Dumpsters shall be screened by a combination of fencing and plantings. Where possible, dumpsters or other trash and recycling collection points shall be located within the building. (10) Stormwater management. Strategies that demonstrate compliance of the construction activities and the proposed project with the most current versions of the Brockton Stormwater Management Standards, the Brockton Stormwater Handbook, Massachusetts Erosion Sediment and Control Guidelines, and, if applicable, additional requirements under the Brockton MS4 Permit for projects that disturb more than one (1) acre and discharge to the city's municipal stormwater system, and an operations and management plan for both the construction activities and ongoing post-construction maintenance and reporting requirements. (c) Buildings: General. (1) Position relative to principal street. The primary building shall have its principal façade and entrance facing the principal street. See also subsection 27-181(g), buildings: corner lots. (2) Entries. Where feasible, entries shall be clearly defined and linked to a paved pedestrian network that includes the public sidewalk. (3) Active use first floors. Buildings fronting Main Street or North Main Street shall have active uses along eighty (80) percent for the first-floor façade. Active use space shall be no less than fifty (50) feet deep. Active uses are defined in section 27-178(a)(1). Ground floor uses and also include residential lobbies, common areas, and amenities. (d) Buildings: Multiple buildings on a lot. (1) For a mixed-use development, uses may be mixed within the buildings or in separate buildings. (2) Parking and circulation on the site shall be organized so as to reduce the amount of impervious surface. Where possible, parking and loading areas shall be connected to minimize curb cuts onto public rights-of-way. (3) A paved pedestrian network shall connect parking to the entries to all buildings and the buildings to each other. (4) The orientation of multiple buildings on a lot should reinforce the relationships among the buildings. All building façade(s) shall be treated with the same care and attention in terms of entries, fenestration, and materials. (5) The building(s) adjacent to the public street shall have a pedestrian entry facing the public street. (e) Buildings: Mixed-use development. (1) In a mixed-use building, access to and egress from the residential component shall be clearly differentiated from access to other uses. Such differentiation may occur by using separate entrances or egresses from the building or within a lobby space shared among different uses. (2) Paved pedestrian access from the residential component shall be provided to residential parking and amenities and to the public sidewalk, as applicable. (3) Materials for non-residential uses shall be stored inside or under cover and shall not be accessible to residents of the development. (4) Parking and circulation on the site shall be organized so as to reduce the amount of impervious surface. Where possible, parking and loading areas shall be connected to minimize curb cuts onto public rights-of-way. (f) Buildings: Shared Outdoor Space. Multi-family housing and mixed-use development shall have common a minimum of twenty-four (24) square feet per unit of outdoor space that all residents can access. Such space may be located in any combination of ground floor, courtyard, rooftop, or terrace. All outdoor space shall count towards the project's minimum open space requirement. (g) Buildings: Corner Lots. A building on a corner lot shall indicate a primary entrance either along one (1) of the street-facing façades or on the primary corner as an entrance serving both streets. (1) Such entries shall be connected by a paved surface to the public sidewalk, if applicable. (2) All façades visible from a public right-of-way shall be treated with similar care and attention in terms of entries, fenestration, and materials. (3) Fire exits serving more than one (1) story shall not be located on either of the street-facing façades. (h) Buildings: Infill Lots. If the adjacent buildings are set back at a distance that exceeds the minimum front yard requirements, infill buildings shall meet the requirements of section 27-179(a), dimensional standards. Otherwise, infill buildings may match the setback line of either adjacent building, or an average of the setback of the two (2) buildings to provide consistency along the street. (i) Buildings: Principal Façade and Parking. Parking shall be subordinate in design and location to the principal building façade. (1) Surface parking. Surface parking shall be located to the rear or side of the principal building. Parking shall not be located in the front setback between the building and any lot line adjacent to the public right-of-way. (2) Integrated garages. The principal pedestrian entry into the building shall be more prominent in design and placement than the vehicular entry into the garage. (3) Parking structures. Building(s) dedicated to structured parking on the same lot as one (1) or more multi-family buildings or mixed-use development shall be incorporated in the design and placement of the multi-family or mixed-use building(s) on the lot. Parked vehicles may not be visible from the public way. (j) Waivers. Upon the request of the Applicant and subject to compliance with the compliance guidelines, the site plan review authority may waive the requirements of this section 27-181, general development standards, in the interests of design flexibility and overall project quality, and upon a finding of consistency of such variation with the overall purpose and objectives of the MCMOD.

(Ord. No. 01-30-2025(2), 1-30-25)

Ask a question about Brockton law

Corpus searches the Brockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.