Sec. 7-337. - Same—Procedure; generally.

The following procedure shall be followed for testing materials pursuant to this article: (a) Six (6) specimens, one and one-half (1½) inches by ten (10) inches, shall be cut at random from the sample sheet. (b) The flame of the Tirrell Burner shall be adjusted so that the blue cone of the flame is approximately one and one-half (1½) inches high and the total height of the flame is six (6) inches. The sample shall be suspended in a vertical position. The test shall be conducted where drafts will not interfere with the proper conduct of the test. The flame shall be applied to the lower end of the sample for ten (10) seconds and withdrawn and the duration of the flaming (afterflame) of the specimens noted. The length of time between disappearance of afterflame and disappearance of visible smoldering (afterglow) shall also be noted.