Sec. 7-586. - Service openings.
(a) All service openings into an incinerator flue shall be provided with a hopper or other charging device constructed of metal of sufficient thickness and durability to prevent cracking, breakage or deformation in normal usage. Such hopper or other charging device shall be firmly built into the masonry and shall be so designed and installed that no part will project into the flue and that the opening to the flue interior shall be closed off while the service opening (hopper) door is fully open. The hopper or other device shall be counterweighed or otherwise devised so that it shall close automatically upon release and be so constructed as to be tightly fitted when in a closed position. (b) No service opening shall be installed in any part of the combustion zone of an incinerator. (c) Instructions shall be posted at each service opening stating that waste shall be deposited only in bags or similar wrappings and warning against introduction of loose dusty materials, flammable liquids or compounds, pressurized cans or bulky or unwieldy articles into the chute opening.
(Code 1965, § 7-239)