§ 14.50 — VEHICULAR ACCESS, PARKING AND LOADING
Code of Ordinances of the City of Cambridge, Massachusetts (Codified through Ordinance No. 2025-8, passed April 7, 2025 (Supp. No. 14)) · Cambridge Zoning Ordinance § 14.50
Corpus is an independent public-information project, not the official City of Cambridge website. Stable reference: corpuslaw.us/code/dca1b7a8-a375-4db8-8480-c0af218afe5a
14.50 - VEHICULAR ACCESS, PARKING AND LOADING
14.51 Access. Buildings erected in the Kendall Center MXD District need not be located on lots which have frontage on a street. However, provisions for access to all buildings by emergency and service vehicles in lieu of public street access shall be made possible by the layout and design of driveways, interior service roads, or pedestrian and bicycle circulation corridors not normally open to vehicular traffic to the reasonable satisfaction of the City of Cambridge Fire Department, and the Cambridge Traffic Department. 14.52 Parking Requirements. Off-street parking regulations for the Kendall Center MXD District shall be as follows: 14.52.1 No on-grade, open parking areas shall be allowed in the District except as provided for in Section 14.52.4. 14.52.2 There are no minimum parking requirements for new development in the District. All proposed development shall be restricted from constructing parking spaces, either on or off the lot within the District, beyond the maximum allowances of Table 1. If a development includes more than one category of use, then the number of spaces allowed for the development shall be the sum of the allowance for each category of use. Where the computation of required spaces results in a fractional number, only a fraction of one half or more shall be counted as one. The Planning Board may approve arrangements for shared parking of such residential parking spaces with commercial spaces or otherwise adjust the minimum parking requirements based on review and analysis of anticipated parking demand within the Transportation Impact Study. At least ten (10) additional parking spaces reserved for car-sharing vehicles shall be provided by the first development project utilizing at least 100,000 square feet of Infill GFA. These spaces are not counted toward maximum parking space ratios. In the event that no car sharing or site-based car rental organization is prepared to offer services, the designated car share spaces may be rented on a monthly basis unless and until an organization agrees to provide the services, if there is clear documentation that such parking spaces are continuously offered to car sharing organizations. Table 1 MXD District Parking Requirements Use | Maximum number of spaces Light Industrial uses allowed by Section 14.21.1 | .8/1000 sq. ft. 1 Office uses and Biotechnology Manufacturing Uses allowed by Section 14.21.2 | .9/1000 sq. ft. Retail and consumer establishment allowed by Section 14.21.3 | .5/1000 sq. ft. Residential uses allowed by Section 14.21.4 Multifamily residences | .75 dwelling unit Hotels or Motels | 1/4 sleeping rooms Public assembly uses allowed by Sections 14.21.3(2), 14.21.3(3), and Section 14.21.5 | 1/15 seats Other uses allowed by Section 14.21.6 and 14.21.7 | .9/1000 sq. ft. 2 1 All space measurements are in terms of square feet of gross floor area. 2 For assembly spaces having no fixed seating. 14.52.3 The parking allowances specified in Table 1 may be satisfied by a lease agreement between the developer and the City, other public entity, or private consortium for use of parking spaces in a public or pooled private parking facility located within the District (or, in the case of the spaces required for residential uses, located outside of the District but within one thousand (1,000) feet of the residential building for which the parking is being provided, measured from property edge to property edge), provided that on a temporary basis, spaces required for residential uses may be within two thousand (2,000) feet of the residential building while permanent residential parking is being constructed. The total number of parking spaces leased and constructed within the district for development on a lot shall not exceed the maximum allowances provided for in Table 2. 14.52.4 Off-street, on-grade parking lots, not enclosed in a structure, may be constructed in the District only on an interim basis in anticipation of later construction of structured parking provided that there is compliance with each of the following: (a) the future parking structure will be constructed within the District but it may be located either on or off the lot; (b) construction of the future parking structure will commence within three years of the date of permit application for development on the lot; (c) such future parking structure may be constructed and/or operated by the applicant or by a public or private entity; (d) the future parking structure will contain sufficient spaces reserved for users of the lot to meet the parking requirements of the lot specified in Table 3; and (e) binding commitments shall exist to guarantee, to the reasonable satisfaction of the Superintendent of Buildings, that requirements (a) through (d) above shall be satisfied. Such commitments shall be made by negotiated lease agreement, deed restriction, covenant, performance bond, or comparable legal instrument. 14.52.5 Regulations governing the layout and design of parking facilities in Article 6.000 of this Ordinance shall not be applicable in the MXD District. This Article 14.000 sets no such regulations for the MXD District. 14.52.6 Bicycle Parking: Bike parking shall be provided as set forth in Section 6.100 of this Zoning Ordinance; provided that in issuing a special permit approving a Concept Plan, the Planning Board may determine that the bicycle parking requirements for individual buildings shown on the Concept Plan may be met utilizing a campus planning approach toward bicycle parking. 14.52.6.1 Intent: To allow flexibility within the high-density environment of the MXD District while providing high quality, equitable, and thoughtfully planned bicycle parking and sustainable transportation amenities for all users, consistent with Section 6.108.2. Given the complexity of infrastructure requirements of the Substation Project, the bicycle parking provisions set forth in Section 6.100 is infeasible, and a comprehensive bicycle parking plan will be needed to help to balance space constraints and competing uses on or near the ground level. 14.52.6.2 Bike Parking Plan: The bicycle parking plan may utilize a combination of the following strategies, or other design provisions that meet the principles of Section 6.108.3: a) Public Bicycle Sharing Facilities: Where a new, standard-size Public Bicycle Sharing Station or larger is provided (i) on the lot, or (ii) on a site within five hundred (500) feet of the lot, with written approval of the City if located on a public street or other City Property, or otherwise by legally enforceable mutual agreement with the owner of the land on which the station is to be located. If Public Bicycle Sharing Station(s) are provided, each bicycle dock within that station may count for up to two (2) required bicycle parking spaces. Should it be deemed beneficial to the operation of a Public Bicycle Sharing system by the Community Development Department and the Public Bicycle Sharing system operator, a developer may meet additional bicycle parking requirements by providing a secure, accessible and geographically central location for the storage and/or maintenance of the publicly shared bicycles. If a Public Bicycle Sharing storage and/or maintenance facility is provided, each designated bicycle storage space shall count for up to one-half (0.5) of a required bicycle parking space b) Countercyclical Bicycle Parking Facility: As the District will contain residential and commercial uses having different peak parking demand times, multiple buildings may share parking facilities within three hundred (300) feet from each other. A shared bicycle parking space may count as a required bicycle parking space for both a residential use and a commercial use within separate buildings within a campus plan. c) Complementary Valet Bicycle Parking: Bicycle parking may be provided through a valet bicycle parking program that is offered free of charge to users. In order to utilize valet bicycle parking, a developer must submit for the Planning Board's approval a plan describing: i. The design of the valet bicycle parking facilities (which shall not be required to conform with the dimensional regulations of Section 6.100). ii. The proposed number of attendants, number of bicycle parking spaces provided, hours of valet service operations, and other pertinent information. When an approved valet bicycle parking program that was utilized to meet the requirements of Section 6.100 is discontinued, the property owner must either bring the bicycle parking spaces into full conformance with the bicycle parking requirements of Section 6.100 or seek approval from the Planning Board for an alternative approach. The combination of the strategies above, or other provisions accepted by the Planning Board, shall allow a project to adjust the minimum required number of bicycle parking spaces, as supported through analysis made available to the Planning Board. 14.53 Loading Requirements. It is the intent of this Section that sufficient off-street loading facilities be constructed within the District to meet the needs of users located there. The requirements of Article 6.000 shall not apply in the MXD District. 14.53.1 All buildings in the MXD District shall provide the number of bays required in Table 3 unless they qualify for one or more of the exemptions below: (1) In buildings with uses in more than one use group under Section 14.21, the loading bay requirements for that use consuming the most gross floor area shall be first computed and required. Only fifty (50%) percent of the floor area of the other uses shall be counted in determining the additional loading requirements. (2) Where there are contractual arrangements for sharing loading and service facilities with other users in the District for a period of ten (10) years of more, a fifty (50%) percent reduction in the loading bay requirements computed in Subsection 14.53.1 or 14.53.1(1) shall be allowed. Such contractual agreement shall be guaranteed to the satisfaction of the Superintendent of Buildings by covenant, deed restriction, or comparable legal instrument. Table 2 MXD Off-Street Loading Requirements (Number of bays required by gross floor area or use) GROSS FLOOR AREA BY USE (1) Use | Up to 25,000 sq. ft. | 25,001—40,000 sq. ft. | 40,001—100,000 sq. ft. | 100,001—200,00 sq. ft. | Over 200,000 sq. ft. for each additional 150,000 sq. ft. Light Industrial Uses allowed by Section 14.21.1 | 1 | 2 | 3 | 1 Office Uses and Biotechnology Manufacturing Uses allowed by Section 14.21.2 | 0 | 1 | 1 | 2 | 1 Retail and consumer service establishments allowed by Section 14.21.3 | 1 | 1 | 2 | 4 | 1 Residential uses allowed by Section 14.21.4 Multifamily residences | 0 | 1 | 1 | 2 | 1 Hotels and motels | 1 | 1 | 1 | 2 | 1 Public assembly uses allowed by Sections 14.21.3(2), 14.21.3(3), 14.21.5 (restaurants, entertainment and recreational facilities) | 0 | 1 | 1 | 2 | 1 Other uses allowed by Section 14.21.6 and 14.21.7 | 0 | 0 | 1 | 2 | 1 14.53.2 Regulations governing the location, layout and design of loading facilities, specified in Section 6.90 of this Ordinance shall not be applicable in the MXD District. This Article 14.000 establishes no such regulations for the MXD District.
(Ord. No. 2020-17, §§ 13—15, 2-3-2021; Ord. No. 2024-2, 6-24-2024; Ord. No. 2025-1, 2-10-2025)
Ask a question about Cambridge law
Corpus searches the Cambridge sections it holds and shows the ones that match, with their citations. Free, no sign-in.
